Applikationen für die pH-, Ionen-, Gelöstsauerstoff- und Konduktivitätsmessung
Die Konzentrationsmessung mit Sensoren ist eine der einfachsten Analysemethoden, die es gibt. Unsere Experten haben zahlreiche Applikationen zu pH-, Ionen-, Gelöstsauerstoff- und Konduktivitätsmessungen von verschiedenen Proben zusammengestellt.
Verwenden Sie die Filter, um unsere Applikationen nach Analyt/Parameter, Probenmatrix, Norm oder Branche zu durchsuchen.
- AN-I-035Sodium content in food using an ion-selective electrode
Excess sodium intake increases the risk of health issues. Ion-selective electrodes (ISEs) offer a fast, accurate, and cost-effective method for measuring sodium in food.
- AN-I-036Sodium content in water using an ion-selective electrode
Groundwater contains many minerals, but can be contaminated by sodium-rich leachate from landfills. Accurate Na determination in water is possible following AOAC 976.25 using the Na-ISE.
- AN-T-235Bestimmung des pH-Wertes in Ruß
Der pH-Wert in Ruß, einem wesentlichen Zusatzstoff in modernen Lithium-Ionen-Batterien, wird in dieser Application Note mithilfe des pH-Meters 913, ausgestattet mit einem Unitrode easyClean, gemäß ASTM D1512 sowie ISO 787-9 und GB genau und zuverlässig analysiert /T 1717-1986.
- AN-I-009Cyanide in water
Cyanides are used in some industrial processes, but if not handled carefully, they could contaminate the wastewater. In an acidic or neutral environment, this contaminated wastewater can form highly toxic hydrogen cyanide gas. Furthermore, the cyanide salts could also poison the environment and enter the ground water system. Therefore, it is essential to monitor the content of cyanide in effluent water. Cyanides can be easily determined with a cyanide ion-selective electrode. This application note presents a method for cyanide analysis according to APHA Method 4500-CN and ASTM D2036.
- AN-I-028Dissolved oxygen in surface water
Oxygen diffuses into water sources from the air via aeration, however several factors can reduce the dissolved oxygen (DO) content in water. First, as water warms up, oxygen is released into the atmosphere. Secondly, oxygen is consumed by bacteria and other microorganisms which feed on organic material. Finally, plants can also consume oxygen in certain situations.Human-induced alterations can have a negative influence on surface water when DO values fall below crucial limits for maintaining the life supporting capacity of freshwater ecosystems. Therefore, monitoring the DO content in surface water by an optical sensor to assess its quality is important.
- AN-PAN-1056Online monitoring of sodium in industrial power plants
In power plants, corrosion is the greatest enemy. If corrosive impurities are present in the circuit streams (e.g., chlorides and hydroxides), deposition of an insulating layer of scale on the heat transfer surfaces occurs, resulting in costly and critical downtimes. To ensure high throughput of power plants, online analysis of critical parameters such as sodium is highly advantageous for safety, protection, and process optimization. With the 2035 Process Analyzer from Metrohm Process Analytics, operators gain the information they need to accurately identify trends, reduce downtimes, and address operational issues before costly problems arise.
- AN-PAN-1040Ammonia in cooling water of thermal power plants
Thermal power plants require enormous amounts of water, using high purity steam at high pressure to rotate turbines. A separate cooling water circuit is implemented, which helps to form a vacuum when the steam condenses after the turbines. Maintaining this vacuum with optimal condensation parameters is critical for the power plant efficiency. The copper condensers are susceptible to corrosion by ammonia, leading to an upper limit of 2 mg/L NH3 set by EPRI in cooling water. Small cracks in the condenser combined with the large pressure differential between the steam circuit and the cooling water circuit will contaminate the high purity water in the boiler, causing major problems and necessitating a shutdown for plant maintenance. Monitoring NH3 online in cooling water with a process analyzer can signal early problems in a plant before significant intermediation is necessary.
- AN-S-387Umfassende Wasseranalytik mit TitrIC flex II
Das TitrIC flex II ist die perfekte Kombination aus Titration, Direktmessung und Ionenchromatographie für die vollautomatische Analyse aller wichtigen Parameter. Diese sind pH-Wert, Leitfähigkeit, Härte, Anionen, Kationen und die Berechnung der Ionenbilanz: umfassende Wasseranalytik aus einer Hand.
- AB-437Installationsanleitung für TitrIC flex II
Das System TitrIC flex II ist für die vollautomatische Analyse von Wasserproben konzipiert und vereinigt Direktmessung, Titration und Ionenchromatographie. In kürzester Zeit bestimmt es wichtige Parameter: von Temperatur, Leitfähigkeit, pH-Wert und Säurekapazität bis hin zur parallelen Analyse der Konzentrationen einzelner Anionen und Kationen mit der resultierenden Wasserhärte und Ionenbilanz. Zur Messung zusätzlicher Parameter ist es jederzeit möglich, weitere Metrohm-Geräte zu integrieren. Dieses Application Bulletin enthält die ausführliche Installationsanleitung für das System TitrIC flex II.
- AB-428Automatische Leitfähigkeitsmessung in elektrisch gering leitenden Wasserproben gemäss USP<645>
Dieses Bulletin beschreibt die automatische Messung der Leitfähigkeit von elektrisch gering leitenden Wasserproben gemäss USP<645>. Die Leitfähigkeitsmessung wird am Beispiel von hochreinem Wasser demonstriert, das unter anderem zum Herstellen von Injektionslösungen im Pharmabereich verwendet wird.