Autolab RHD Microcell HC
AUT.RHD
Autolab RHD Microcell HC
vi
AUT.RHD
-
- Measuring Cell TSC Battery Standard
- AUT.RHD.TSCBATT
- The TSC Battery is a closed measuring cell intended for assembling half or full battery or supercap cells with e.g. active materials and separators. It is also suitable for investigating solid or gel-like samples in contact with metal electrodes in a plate/plate geometry.You have flexibility with cell configuration either two and three electrode measurements can be performed by inserting a microreference electrode from the side.The standard variant contains flat metal electrodes. For current collectors designed for using elemental lithium as electrode material please refer to the extended variant."This cell is airtight and thus shielded against atmosphere and can be used with moisture-sensitive samples.
- <p>The <strong>TSC Battery</strong> is a closed measuring cell intended for assembling <strong>half </strong>or <strong>full battery</strong> or <strong>supercap cells</strong> with e.g. active materials and separators. It is also suitable for investigating solid or gel-like samples in contact with metal electrodes in a plate/plate geometry.</p><p>You have <strong>flexibility with cell configuration</strong> either <strong>two and three electrode measurements</strong> can be performed by inserting a microreference electrode from the side.</p><p>The standard variant contains flat metal electrodes. For current collectors designed for using elemental lithium as electrode material please refer to the extended variant."</p><p>This cell is airtight and thus shielded against atmosphere and can be used with moisture-sensitive samples.</p><p><br /> </p>
- PCS
- 1
- Measuring Cell TSC Surface
- AUT.RHD.TSCSURF
- The TSC Surface is a closed cell designed for electrochemical measurements on flat samples and can be used to study the electrochemical interface between a well defined working electrode and solution and the kinetics of electron transfer reactions. This cell, like all other cells is suitable for measurements with ionic liquids, but it can also be used with aqueous and organic solvents and for corrosion measurements.
- <p>The TSC Surface is a closed cell designed for electrochemical measurements on flat samples and can be used to study the electrochemical interface between a well defined working electrode and solution and the kinetics of electron transfer reactions. This cell, like all other cells is suitable for measurements with ionic liquids, but it can also be used with aqueous and organic solvents and for corrosion measurements.</p><p> </p><p> </p>
- PCS
- 1