アクセサリー検索
BWT-840000961
ビデオマイクロスコープ付きラマンサンプル採取システム (785 nm)ラボおよび産業用のB&W Tek社製ラマンプローブを用いた使用のためのビデオマイクロスコープ付きサンプル採取システム。作動距離16 mmで20倍拡大の対物レンズ付き。X、Y、およびZ軸方向の粗調整ならびに微調整、ターゲティング用同軸LED照明、サンプル観察のためのビデオカメラが使用可能であり、標準マイクロスコープ対物レンズと互換性があります。プローブは含まれておらず、個別にご購入いただけます。785 nmコンフィグレーション。BAC151C-785
CAST
μStat Cable connector for Screen-Printed ElectrodesConnects any DropSens equipment with DropSens Screen-Printed Electrodes
CNFSOL
Carbon Nanofibres SolutionCarbon Nanofibres Solution produced via the catalytic carbon vapour deposition process. The manufacturing processes provide a highly graphitized material without amorphous carbon – Available in 1.0 mL and 5.0 mL.
EC.Raman.Battery
Metrohm Hyphenated EC-Raman Battery SolutionAn Autolab modular PGSTAT302N with an Electrochemical Impedance Spectroscopy (EIS) module installed and a B&W Tek i-Raman Plus 532 H System are the foundation of this system. Depending on your cell size and design you can add either a B&W Tek Raman Video Micro-Sampling System (532 nm), or the B&W Tek Raman Probe Holder.Get ready to track age-induced structural changes, electrolyte decomposition, and solid electrolyte interphase (SEI) formation with your EC-Raman Battery Solution.It is easy to get started, see instant results, all with an instrument you can upgrade as your research progresses.• Two editable hyphenated EC-Raman procedures for the NOVA software as well as the BWSpec software for extended data analysis.• An electrochemical workstation with high accuracy EIS.• Future-proof your research with the ability to add up to 7 additional modules post-installation.Choose, depending on your cell size, either a B&W Tek Raman Video Microsampling System (532 nm), or the B&W Tek Raman Probe Holder. B&W Tek Raman Video Microsampling System (532 nm) can accommodate cells up 30 mm high.B&W Tek Raman Probe Holder can accommodate large battery-dedicated EC-Raman cells.
FLWCL
Flow Cell for Screen-Printed ElectrodesMethacrylate wall-jet Flow-Cell for FIA. Suitable to be used with standard format Screen-Printed Electrodes with the electrochemical cell in the middle of the strip. Closing system with powerful magnets Fittings included.
BICAST
μStat Cable connector for Dual Screen-Printed ElectrodesConnects any DropSens equipment with DropSens Dual Screen-Printed Electrodes
BWT-840000395
ラマンプローブホルダーラボ品質のB&W Tek社製ラマンプローブを用いた使用のためのプローブホルダー。手動の XYZ 粗調整および微調整を提供します。
CNTSOL
-COOH funcionalized Multi-Walled Carbon Nanotubes SolutionCarbon nanotubes are produced via CVD and purified to remove free amorphous carbon deposits and catalyst metallic particles. They are functionalized with -COOH groups - Available in 1.0 mL and 5.0 mL.
EC.Raman.Corrosion.Explorer
Metrohm Hyphenated EC-Raman Explorer Corrosion SolutionIncludes an Autolab modular PGSTAT302N with an Electrochemical Impedance Spectroscopy (EIS) module installed, a B&W Tek i-Raman Plus 532 H System, a B&W Tek Raman Video Microsampling System (532 nm) and an Autolab Trigger cable.Ready when you are, the EC-Raman Explorer Corrosion Solution is easy to use. Get started quickly with a versatile potentiostat/galvanostat that can be expanded as your research develops.• Two editable hyphenated EC-Raman procedures for the NOVA software as well as the BWSpec software for extended data analysis.• An electrochemical workstation with high accuracy EIS.• Future-proof your research with the ability to add up to 7 additional modules post-installation.• 532 nm laser excitation for higher Raman signal• Visual surface inspection with the microsampling system
BWT-840000609
ラマンビデオサンプル採取システムのためのカバー直接的なレーザー放射から目および/または皮膚を保護するための、ラマンサンプル採取システム (すなわちマイクロスコープ、プローブホルダー) 用のカバー。ハウジングは、サンプルの装填とシステムの操作を容易にするため、人間工学に基づき設計されています。波長 532 nm、785 nm および 1064 nm における使用のため。
CABSTAT1
μStat 8000(P)/4000(P) one node cable connector for conventional electrodesConnects individual nodes of the μStat 8000(P)/4000(P) to conventional electrodes
EC.Raman.ECAT.Explorer
Metrohm Hyphenated EC-Raman Explorer Electrocatalysis SolutionIncludes an Autolab modular PGSTAT302N with an Electrochemical Impedance Spectroscopy (EIS) module installed, a B&W Tek i-Raman Plus 532 H System, a B&W Tek Raman Video Microsampling System (532 nm) and an Autolab Trigger cable.Synchronize your electrochemical measurements with in situ Raman spectroscopy providing:• Simultaneous structural and functional information about your catalysts• Operando measurements allow for tracking changes of the catalyst structure, identifying adsorbed products or intermediates• A powerful modular potentiostat/galvanostat with current ranges from 10 nA to 1 A.• An electrochemical workstation with high accuracy EIS.• Two editable hyphenated EC-Raman procedures for the NOVA software as well as the BWSpec software for extended data analysis.• Future-proof your research with the ability to add up to 7 additional modules post-installation.• 532 nm laser excitation for higher Raman signalAll without complicated setups or complex training.
FLWCL-PEEK
Flow Cell in PEEK for Screen-Printed ElectrodesPEEK wall-jet Flow-Cell for FIA. Suitable to be used with standard format Screen-Printed Electrodes with the electrochemical cell in the middle of the strip. Closing system with powerful magnets. Fittings included.
GPHSOL
Graphene SolutionGraphene Solution - Available in 1.0 mL and 5.0 mL.
BWT-810000389
9.5 mm 測定プローブ用ラマンキュベットホルダーBCR100A ラマンキュベットホルダーにより、ラマンプローブをホルダーに固定することで液体および粉末の容易なラマンスペクトル測定ができるようになります。この付属品は、いまだかつてない再現性のために三点精密ねじ付きの内蔵ミラーを使用しており、これによりラマン信号を従来のキュベットホルダーの3倍まで増強します。これは、プローブシャフトがキュベットに直接接触しないように設計されており、またバックグラウンド蛍光を減量するためのライトトラップも含まれています。BCR100A は、直径 9.5 mm または 12 mm のプローブのための設計モデルで入手可能で、外径 12.5 mm x 12.5 mm の各標準キュベット (波長 1 cm) とともに液体や粉末のサンプル採取に用いられます。
CAST8X
μStat 8000(P) cable connector for format 8X Screen-Printed ElectrodesConnects μStat 8000(P) equipment to 8X format Screen-Printed Electrodes
EC.Raman.Corrosion.Starter
Metrohm Hyphenated EC-Raman Starter Corrosion SolutionIncludes a compact Autolab PGSTAT204 with an Electrochemical Impedance Spectroscopy (EIS) module installed, a B&W Tek i-Raman Plus 532 H System, a B&W Tek Raman Video Micro-Sampling System (532 nm) and an Autolab Trigger cable. Get started quickly and have a dual perspective on corrosion phenomena. The EC-Raman Starter Corrosion Solution provides you with the instrumentation you need to get started.• Two editable hyphenated EC-Raman procedures for the NOVA software as well as the BWSpec software for extended data analysis.• An electrochemical workstation with high accuracy EIS.• Ready-to-go and simple to use.• 532 nm laser excitation for higher Raman signal• Visual surface inspection with the microsampling system
FLWCL-P
Flow Cell in Polypropylene for Screen-Printed ElectrodesPolypropylene wall-jet Flow-Cell for FIA. Suitable to be used with standard format Screen-Printed Electrodes with the electrochemical cell in the middle of the strip. Closing system with powerful magnets. Fittings included.
GPHOXSOL
Graphene Oxide SolutionGraphene Oxide Solution, based in the modification of the Hummer's Method specially designed for electrode modification providing an enhanced electrochemical active area and improved electronic transfer properties - Available in 1.0 mL and 5.0 mL.
BWT-810000682
携帯型ラマン装置用外付けバッテリー常に一定で 12 VDC を供給する外付けリチウムイオン電池。(モデル i-Raman-Plus、i-Raman Pro および i-Raman EX と互換性あり)。EBP106
CAST1X8
μStat 8000(P) cable connector for individual Screen-Printed ElectrodesConnects μStat 8000(P) equipment with individual Screen-Printed Electrodes
EC.Raman.ECAT.Starter
Metrohm Hyphenated EC-Raman Starter Electrocatalysis SolutionIncludes a compact Autolab PGSTAT204 with an Electrochemical Impedance Spectroscopy (EIS) module installed, a B&W Tek i-Raman Plus 532 H System, a B&W Tek Raman Video Microsampling System (532 nm) and an Autolab Trigger cable.Discover simultaneous structural and functional information about your catalysts quickly without complicated setups or worries about synchronizing measurements. This is all possible with the EC-Raman Starter Solution.• An electrochemical workstation with high accuracy EIS.• Two editable hyphenated EC-Raman procedures for the NOVA software as well as the BWSpec software for extended data analysis.• Measurements are automatically synchronized.• 532 nm laser excitation for higher Raman signal.
FLWCL-SC
Flow Cell with screws for Screen-Printed ElectrodesMethacrylate (top part) wall-jet Flow-Cell for FIA. Suitable to be used with standard format Screen-Printed Electrodes with the electrochemical cell in the middle of the strip. Closing system with screws. Fittings included.
GPHOXSOL-AQU
Graphene Oxide Solution-AqueousAqueous Aqueous graphene Oxide Solution, based in the modification of the Hummer's Method specially designed for electrode modification providing an enhanced electrochemical active area and improved electronic transfer properties.- Available in 1.0 mL and 5.0 mL.
BWT-840000962
ビデオマイクロスコープ付きラマンサンプル採取システム (532 nm)ラボおよび産業用のB&W Tek社製ラマンプローブを用いた使用のためのビデオマイクロスコープ付きサンプル採取システム。作動距離16 mmで20倍拡大の対物レンズ付き。X、Y、およびZ軸方向の粗調整ならびに微調整、ターゲティング用同軸LED照明、サンプル観察のためのビデオカメラが使用可能であり、標準マイクロスコープ対物レンズと互換性があります。プローブは含まれておらず、個別にご購入いただけます。532 nmコンフィグレーション。BAC151C-532
CABSTATMULTI
μStat 8000(P)/4000(P) multichannel cable connector for conventional electrodesConnects the multichannel option of the μStat 8000(P)/4000(P) to up to 8/4 conventional WE sharing one conventional AUX and one conventional REF
CAC
Cable connector for Screen-Printed ElectrodesConnects DropSens Screen-Printed Electrodes to any kind of potentiostat. Recommended when working in batch or flow analysis.
FLWCL-IDE
Flow Cell for Interdigitated ElectrodesMethacrylate wall-jet Flow-Cell for FIA. Suitable to be used with IDE electrodes ref. G-IDEAU10, G-IDEAU5,G-IDEPT10, G-IDEPT5, G-IDECONAU10 and G-IDECONPT10. Closing system with powerful magnets. Fittings included.
MCSOL
Mesoporous Carbon SolutionMesoporous Carbon Solution is a homogeneous, black solution with a high purity of mesoporous carbon nanopowder.- Available in 1.0 mL and 5.0 mL
BICAC
Cable connector for Dual Screen-Printed ElectrodesConnects DropSens Dual Screen-Printed Electrodes to any kind of potentiostat. Recommended when working in batch or flow analysis.
BWT-840000963
ビデオマイクロスコープ付きラマンサンプル採取システム (532/785 nm、デュアル)ラボおよび産業用のB&W Tek社製ラマンプローブを用いた使用のためのビデオマイクロスコープ付きサンプル採取システム。作動距離16 mmで20倍拡大の対物レンズ付き。X、Y、およびZ軸方向の粗調整ならびに微調整、ターゲティング用同軸LED照明、サンプル観察のためのビデオカメラが使用可能であり、標準マイクロスコープ対物レンズと互換性があります。プローブは含まれておらず、個別にご購入いただけます。デュアル532/785 nmコンフィグレーション.BAC151C-532/785
FLWCL-IDE-TEF
Flow Cell in Teflon for Interdigitated ElectrodesTeflon wall-jet Flow-Cell for FIA. Suitable to be used with IDE electrodes ref. G-IDEAU10, G-IDEAU5, G-IDEPT10, G-IDEPT5, G-IDECONAU10 and G-IDECONPT10. Closing system with powerful magnets. Fittings included.
GPHOX
Graphene OxideGraphene oxide prepared by a modification of the Hummer's method. This yields a material with a significant number of oxygen-containing functional groups which assures homogeneous colloidal suspensions in polar solvents without addition of any surfactant. - Available in 0.1 gr and 1.0 gr.
BWT-840000985
ビデオマイクロスコープ付きラマンサンプル採取システム (1064 nm)ラボおよび産業用のB&W Tek社製ラマンプローブを用いた使用のためのビデオマイクロスコープ付きサンプル採取システム。作動距離16 mmで20倍拡大の対物レンズ付き。X、Y、およびZ軸方向の粗調整ならびに微調整、ターゲティング用同軸LED照明、サンプル観察のためのビデオカメラが使用可能であり、標準マイクロスコープ対物レンズと互換性があります。プローブは含まれておらず、個別にご購入いただけます。1064 nmコンフィグレーション。BAC151C-1064
CAC-P
Cable connector for Screen-Printed Electrodes/Plastic SubstrateConnects DropSens Screen-Printed Electrodes over Plastic Substrate with any kind of potentiostat
FLWCL-WS
Flow Cell for Work in Solution Screen-Printed ElectrodesMethacrylate wall-jet Flow-Cell for FIA. Suitable to be used with work in solution format Screen-Printed Electrodes with the electrochemical cell at the end of the strip. Closing system with powerful magnets. Fittings included.
MWCNT
Multi-Walled Carbon NanotubesMulti-Walled Carbon Nanotubes grown by CVD process purified to more than 95%.
BWT-810000542
12 mm 測定プローブ用ラマンキュベットホルダーBCR100A ラマンキュベットホルダーにより、ラマンプローブをホルダーに固定することで液体および粉末の容易なラマンスペクトル測定ができるようになります。この付属品は、いまだかつてない再現性のために三点精密ねじ付きの内蔵ミラーを使用しており、これによりラマン信号を従来のキュベットホルダーの3倍まで増強します。これは、プローブシャフトがキュベットに直接接触しないように設計されており、またバックグラウンド蛍光を減量するためのライトトラップも含まれています。BCR100A は、直径 9.5 mm または 12 mm のプローブのための設計モデルでご購入いただくことができ、外径 12.5 mm x 12.5 mm の各標準キュベット (光路長 1 cm) とともに液体や粉末のサンプル採取に用いることができます。直径 12 mm の RIS100 シリーズのシャフトでの使用のための液体サンプル用 BCR100A―12 mm キュベットホルダー。プローブは納品内容に含まれません。
CACIDE
Cable connector for Interdigitated Electrodes/Glass SubstrateConnects DropSens Interdigitated Electrodes over Glass Substrate with any kind of potentiostat
CFLWCL-WE
Flow Cell - Only Working ElectrodeMethacrylate wall-jet Flow-Cell for FIA.Its o-ring entraps only the working electrode. Suitable to be used with standard Screen-Printed Electrodes with the electrochemical cell in the center of the strip. Closing system with powerful magnets. Fittings included.
MWCNT-COOH
-COOH functionalized Multi-Walled Carbon Nanotubes-COOH functionalized Multi-Walled Carbon Nanotubes (approx. 5% functionalisation) grown by CVD process purified to more than 95%.
CACIDE-P
Cable connector for Interdigitated Electrodes/Plastic SubstrateConnects DropSens Interdigitated Electrodes over Plastic Substrate with any kind of potentiostat
CFLWCL-WE-TEF
Flow Cell in Teflon - Only Working ElectrodeTeflon wall-jet Flow-Cell for FIA.Its o-ring entraps only the working electrode. Suitable to be used with standard Screen-Printed Electrodes with the electrochemical cell in the center of the strip. Closing system with powerful magnets. Fittings included.
CAC8X
Cable connector for format 8X Screen-Printed ElectrodesConnects DropSens 8X format Screen-Printed Electrodes with any kind of (multi) potentiostat
CFLWCL-MAGN
Flow Cell for magnetic assays with Screen-Printed ElectrodesMethacrylate wall-jet Flow-Cell associated with a powered magnet designed to do FIA with magnetic beads. Suitable to be used with standard format Screen-Printed Electrodes with the electrochemical cell in the middle of the strip. Fittings included.
AUNP-COL
Colloidal Gold Nanoparticles SolutionColloidal Gold Nanoparticles Solution produced through colloidal synthesis methods, reducing a metal salt precursor in a solution and with the present of a stabilizer agent. Colloidal nanospheres Nanoparticles can be later purified and concentrated removing any stabilizing agent. Available in 25 mL.
DSC
Connector for Screen-Printed ElectrodesConnector suitable to connect DropSens SPEs to any kind of potentiostat. Recommended when working by placing a drop over the electrode