- 8.000.6007Determination of sulfate in denatured ethyl alcohol according to ASTM D7319
In this poster a convenient direct injection suppressed ion chromatographic method for determining chloride and sulfate in denatured ethanol samples according to ASTM D7319 is presented.
- 8.000.6011Ion chromatographic determination of anions, cations and organic acids in biofuels
Quality and process control of biofuels require straightforward, fast and accurate analysis methods. Ion chromatography (IC) is at the leading edge of this effort. Traces of anions in a gasoline/ethanol blend can accurately be determined in the sub-ppb range after Metrohm Inline Matrix Elimination using anion chromatography with conductivity detection after sequential suppression. While the analyte anions are retained on the preconcentration column, the interfering organic gasoline/bioethanol matrix is washed away.Detrimental alkali metals and water-extractable alkaline earth metals in biodiesel are determined in the sub-ppm range using cation chromatography with direct conductivity detection applying automated extraction with nitric acid and subsequent Metrohm Inline Dialysis. Unlike high-molecular substances, ions in the high-ionic strength matrix diffuse through a membrane into the low-ionic water acceptor solution. In biogas reactor samples, low-molecular-weight organic acids stem from the biodegradation of organic matter. Their profile allows important conclusions concerning conversion in the anaerobic digestion reaction. Volatile fatty acids and lactate can be accurately determined by using ion-exclusion chromatography with suppressed conductivity detection after inline dialysis or filtration.
- 8.000.6012Automated logical dilution for ion chromatographic determinations
The combination of 850 Professional IC, 858 Professional Sample Processor, Dosino and MagIC NetTM software offers a variety of sophisticated ion chromatographic sample preparation techniques. One of these is the automated inline dilution of samples.After the first sample injection, MagIC NetTM verifies if the area of the sample peak lies within the calibration range. If the measured peak area is outside these limits, the software calculates the appropriate dilution factor, dilutes and automatically re-injects the sample. For all investigated ions (Li+, Na+, K+, Ca2+, Mg2+, F-, Cl- , NO2-, Br-, NO3-, SO42- ), automated logical dilution yielded coefficients of determination (R2) better than 0.9999. Direct-injection recoveries for cations and anions were within 98.6…99.5% and 93.4…100.4% respectively. In contrast, after logical dilution, recoveries for cations and anions were within 100.1…102.9% and 98.2…102.6% respectively. The relative standard deviations for all determinations involving diluted sample solutions were smaller than 0.91%.
- 8.000.6013Analysis of produced water contaminants by ion chromatography
The analytical challenge treated by the present work consists in detecting sub-ppm quantities of bromide, sulfate, aliphatic monocarboxylic acids and several alkaline earth metals in the presence of very high concentrations of sodium and chloride. Bromide, sulfate, acetate and butyrate can be reliably determined by suppressed conductivity detection. Due to matrix effects, propionate can only be detected qualitatively. This drawback can be overcome by coupling the ion chromatograph (IC) to a mass spectrometric (MS) detector. This results in reduced matrix interferences and significantly enhanced sensitivities. The cations magnesium, barium and strontium are determined by non-suppressed conductivity detection.
- 8.000.6014Determination of anions and cations in aerosols by ion chromatography
The study of adverse effects of air pollution requires semi-continuous, rapid and accurate measurements of inorganic species in aerosols and their gas phase components in ambient air. The most promising instruments, often referred to as steam collecting devices, are the Particle-Into-Liquid-Sampler (PILS) coupled to wet-chemical analyzers such as a cation and/or anion chromatograph (IC) and the Monitoring instrument for AeRosols and GAses (MARGA) with two integrated ICs. Both instruments comprise gas denuders, a condensation particle growth sampler as well as pump and control devices. While PILS uses two consecutive fixed denuders and a downstream growth chamber, the MARGA system is composed of a Wet Rotating Denuder (WRD) and a Steam-Jet Aerosol Collector (SJAC). Although the aerosol samplers of PILS and MARGA use different assemblies, both apply the technique of growing aerosol particles into droplets in a supersaturated water vapor environment. Previously mixed with carrier water, the collected droplets are continuously fed into sample loops or preconcentration columns for on-line IC analysis. While PILS has been designed to sample aerosols only, MARGA additionally determines water-soluble gases. Compared to the classical denuders, which remove gases from the air sample upstream of the growth chamber, MARGA collects the gaseous species in a WRD for on-line analysis. In contrast to the gases, aerosols have low diffusion speeds and thus neither dissolve in the PILS denuders nor in the WRD. Proper selection of the ion chromatographic conditions of PILS-IC allows a precise determination, within 4 to 5 minutes, of seven major inorganic species (Na+, K+, Ca2+, Mg2+, Cl-, NO3- and SO4 2-) in fine aerosol particles. With longer analysis times (10-15 minutes) even airborne low-molecular-weight organic acids, such as acetate, formate and oxalate can be analyzed. MARGA additionally facilitates the simultaneous determination of HCl, HNO3, HNO2, SO2 and NH3.PILS and MARGA provide semi-continuous, long-term stand-alone measurements (1 week) and can measure particulate pollutants in the ng/m3 range.
- 8.000.6016Advantages of multidimensional ion chromatography for trace analysis
The analytical challenge treated in the present work consists in detecting trace concentrations (ppb) of bromide in the presence of a strong chloride matrix. This problem was overcome by separating the bromide ions from the main fraction of the early eluting chloride matrix (several g/L) by applying two sequential chromatographic separations on the same column. After the first separation, the main fraction of the interfering chloride matrix is flushed to waste, while the later eluting anions are diverted to an anion-retaining preconcentration column. After elution in counter flow, the bromide ions are efficiently separated from the marginal chloride residues. The four-point calibration curves for bromide and sulfate are linear in the range of 10…100 µg/L and 200…800 µg/L and yield correlation coefficients of 0.99988 and 0.99953 respectively. For the method shown here, a second injection valve and a preconcentration column are the only additional devices needed to master this demanding separation problem.
- 8.000.6020Titrimetric analyses of biofuels
Several testing methods such as the determination of the acid and the iodine numbers in biodiesel as well as the quantification of sulfate and chloride in bioethanol are described.
- 8.000.6042Straightforward multipoint calibration using a single standard
The combination of 850 Professional IC, 858 Professional Sample Processor, Dosino and MagIC NetTM software offers a variety of automated ion chromatographic sample preparation and calibration techniques available as an anion, cation or dual channel system. Calibration is straightforward and requires only one multi-ion standard.Inline calibration allows the calibration of any standard concentration in the ppt range by using one single stable standard solution at the ppb level. By using a preconcentration column and switching the valves one, two or more times different calibration concentrations at the ultra-trace level can be created with unprecedented reproducibility. The inline preconcentration technique uses a pre-concentration column and is ideally suited for trace analysis in complex matrices, especially when combined with matrix elimination. Besides facilitating the preparation of g/L to ng/L calibration graphs Metrohm`s intelligent techniques are capable of logical decision making. While Metrohm`s intelligent Partial Loop technique (MiPT) allows samples with a wide concentration range to be injected without previous manual dilution, the intelligent inline dilution technique, after the first sample injection, compares peak areas, calculates, if necessary, the dilution factor, dilutes and automatically re-injects the sample. The presented inline techniques allow the rationalization of the time-consuming, error-prone and cost-intensive manual preparation of standard solutions. They guarantee that the determined sample concentrations always lie within the calibration range. Higher sample throughputs as well as lower analysis costs and improved data reliability are achieved.
- 8.000.6043Automated dialysis as a sample preparation tool in ion chromatography
The analytical challenge treated in the present work consists in the determination of chloride, phosphate and sulfate in the presence of difficult sample matrices that interact with the stationary column phase or even render it unusable. Metrohm`s patented stopped-flow dialysis coupled to the new 881 Compact IC pro ion chromatograph overcomes these drawbacks. Two standard solutions covering the concentration ranges 1.0…3.6 mg/L and 10…36 mg/L as well as two samples, an ultra-high temperature (UHT) processed milk and a baby milk powder, were characterized in terms of analyte concentration, relative standard deviation, calibration quality, carryover and recovery rates. While the five-point calibration curves yielded correlation coefficients (R) better than 0.9999, carryover (between two subsequent injections of a concentrated sample and a blank) was less than 0.49%. Recoveries for the low (10…36 mg/L) and high standard concentrations (1.0…3.6 mg/L) were within 91…99% and 94…100%, respectively. Automated compact stopped-flow dialysis is a leading-edge sample preparation technique that ensures optimum separation performance by effectively protecting the column from detrimental matrix compounds.
- 8.000.6044Fully automated sample preparation for liquid chromatographic content determinations
Inline coupling of the 815 Robotic Soliprep with an ion chromatograph (IC) allows the straightforward determination of anions and cations in tablets. After automatic solvent addition and subsequent comminution, the homogenized tablet samples (Singulair and Bezafibrat) are filtered and subsequently transferred to the injector. The completely automated sample preparation saves both time and money, guarantees traceability of each sample preparation step and yields correct and precise results. In the range of 0.2…50 mg/L, six-point calibration curves for anions and cations yield correlation coefficients better than 0.99990 and 0.99991, respectively. While relative standard deviations (RSDs) for sub-ppm levels of nitrate, sulfate, calcium and magnesium in Singulair and Bezafibrat are smaller than 3.64%, RSD of ppm levels of chloride is better than 0.83%. The application of further inline sample preparation steps such as pulverizing, extracting, filtering or diluting facilitates numerous custom-tailored setups for ion determinations in exacting matrices such as animal feed, sediments or food.
- 8.000.6052Quality assurance of biofuels
This poster provides an overview of ion chromatographic methods combined with inline sample preparation for the determination of anions and water-extractable cations in biofuels. In addition, the determination of the oxidation stability is described.
- 8.000.6058PILS-ICによる浮遊粒子状物質の分析
この研究では、オフラインの手動フィルター抽出とそれに続くイオンクロマトグラフ分析を含むフィルターベースの方法で得られた空気サンプリングデータを、イオンクロマトグラフ(PILS-IC)に接続された自動Particle-Into-Liquid-Samplerで得られたデータと比較します。 -ICは、エアロゾルサンプリング用の簡単な機器であり、長期間の無人操作をほぼリアルタイムで測定できるため、エアロゾル粒子のイオン組成の急激な変化を監視するために不可欠なツールです。
- 8.000.6064Microbore columns: a contribution to green chemistry
Available sample size, mass sensitivity, efficiency and the detector type are important criteria in the selection of separation column dimensions. Compared to conventional 4 mm i.d. columns, microbore columns excel, above all, by their low eluent consumption. Once an eluent is prepared, it can be used for a long time. Additionally, the lower flow rates of microbore columns facilitate the hyphenation to mass spectrometers due to the improved ionization efficiency in the ion source.With the same injected sample amount, a halved column diameter involves a lower eluent flow and results in an approximate four-fold sensitivity increase. In a converse conclusion, this means that with less sample amount, microbore columns achieve the same chromatographic sensitivity and resolution than normal bore columns. This makes them ideally suited for samples of limited availability.
- 8.000.6065Automated ion chromatographic determinations over six orders of magnitude
Metrohm`s intelligent Preconcentration Technique with Matrix Elimination (MiPCT-ME) excels in its capacity to perform automatic ion chromatographic determinations over 6 orders of magnitude. Crucial requirements for this are the system`s intelligence and the exact measurement of the sample volume. While the intelligence allows to compare results and take decisions, the dosing device takes over the high-precision liquid handling of even single-digit microliter volumes to the preconcentration column. By using only one analytical setup and without additional rinsing, samples containing both ultratraces and high concentrations can be analyzed.As the other Metrohm Inline Techniques, the MiPCT-ME technique presented reduces the workload, ensures complete traceability, is free of carryover effects and significantly improves accuracy and reproducibility of the results.
- 8.000.6071Trace-level determination of anions in the primary circuit of a PWR-type nuclear power plant using ion chromatography after inline sample preparation
The poster presents the ion chromatographic determination of organic degradation products such as glycolate, formate and acetate besides the standard anions fluoride, chloride, nitrate and sulfate.
- 8.000.6073Determination of anions in concentrated nitric acid by ion chromatography: the influence of temperature on column selectivity
Determination of chloride and sulfate in the presence of high nitrate concentrations. Optimization of the chromatographic separation by variation of the temperature and eluent composition.
- 8.000.6075Determination of pyrophosphate, trimetaphosphate, tripolyphosphate, and standard ions in detergents or fertilizers using IC with a high-capacity suppressor
Three different suppressor systems are compared in terms of sensitivity. Additionally, binary gradient elution was applied to analyze phosphates in the presence of mono- and divalent ions.
- 8.000.6076Sequential suppression for conductivity detection in ion chromatography
The poster describes how different suppressors (MSM and MCS) work and mentions possible applications.
- 8.000.6086Semi-continuous determination of anions, cations, and heavy metals in aerosols using PILS-IC-VA
This poster presents an approach that couples a Particle-Into-Liquid-Sampler (PILS) to a dual-channel ion chromatograph (IC) for measurement of aerosol anions and cations and a voltammetric measuring stand (VA) to determine the heavy metals. Feasibility of the PILS-IC-VA online system was demonstrated by collecting aerosol samples in Herisau Switzerland, at defined time intervals; air pollution events were simulated by burning lead- and cadmium-coated sparklers.
- 8.000.6091Ion chromatographic determination of halogens and sulfur in solids using combustion as inline sample preparation
The Combustion IC system presented allows the automated determination of organic halogen and sulfur compounds in all flammable samples. Both combustion digestion, which is automatically controlled with a flame sensor, and the professional Liquid Handling guarantee highest precision and trueness. This poster describes the determination of the halogen and sulfur content in a certified polymer standard, a coal reference material as well as in latex and vinyl gloves.
- 8.000.6107USP 近代化イニシアチブ: イオンクロマトグラフィーによる原薬中のイオン性不純物
AAPS会議にてUSPと共同で発表されたこのポスターは、原薬、炭酸水素カリウムならびに炭酸カリウム中の塩化物および硫酸塩の測定のためのICメソッドの検証に弊社が成功したことを紹介するものです。ここで提案されているICメソッドは、比濁法/目視比較メソッドの限界を克服するものです。
- AB-027Potentiometric titration of chloride and bromide in the presence of each other
If chloride and bromide are present in approximately equal molar concentrations they can be titrated directly with silver nitrate solution after addition of barium acetate. If, however, the molar ratio n(Br-) : n(Cl-) changes from 1 : 1 to 1 : 5, 1 : 10, 5 : 1 or 10 : 1 then greater relative errors must be expected with this method. The Bulletin describes an additional titration method that allows bromide to be determined in the presence of a large excess of chloride. The determination of small chloride concentrations in the presence of a large excess of bromide is not possible by titration.
- AB-069Titrimetric methods for the chemical analysis of pasta
The quality of egg-based pasta is primarily determined by its egg content. Also of importance, however, is the water content, which influences the storage life of the product, as well as the degree of acidity which, in the case of high values, indicates undesirable acidification during processing or drying. A check of the chloride content shows whether salt has been added to the pasta.
- AB-085Analysis of jams, fruit and vegetable juices, and their concentrates
This Bulletin describes analysis methods for determining the following parameters: pH value, total titratable acid, ash alkalinity, formol number, total sulfurous acid, chloride, sulfate, calcium, and magnesium. These methods are suitable for the analysis of jams, fruit and vegetable juices, and their concentrates.
- AB-087自動滴定装置による乳製品の分析
この技術資料では電位差自動滴定装置を使用した、DIN 10316、ISO/TS 11869、IDF/RM 150、ISO 6091、IDF 86準拠による牛乳とヨーグルトに含まれる酸の測定。EN ISO 5943、IDF 88、ISO 15648、IDF 179、ISO 21422、IDF 242準拠による牛乳、バター、チーズに含まれる塩化物含有量の測定について紹介しています。さらに、TETを用いた牛乳に含まれるナトリウム含有量の測定について紹介しています。AOCS Cd 12b-92、ISO 6886、GB/T 21121準拠によるバターの酸化安定性の測定、イオンクロマトグラフィによるラクトースフリーの牛乳中のラクトースの測定についても説明しています。
- AB-089Potentiometric analysis of anodizing baths
This Bulletin describes potentiometric titration methods for checking sulfuric acid and chromic acid anodizing baths. In addition to the main components aluminum, sulfuric acid, and chromic acid, chloride, oxalic acid, and sulfate are determined.
- AB-090Potentiometric analysis of tin plating baths
Potentiometric titration methods for the analysis of acid and alkaline tin plating baths are presented. The following methods are described: tin(II) / tin(IV) / total tin, free fluoroboric acid, or free sulfuric acid, chloride in acidic tin baths, free hydroxide, and carbonate in alkaline tin baths.
- AB-130Chloride titrations with potentiometric indication
Besides acid-base titrations, the titrimetric determination of chloride is one of the most frequently used titrimetric methods of analysis. It is employed more or less frequently in practically every laboratory. This Bulletin shows you how to determine chloride in a wide range of concentrations using automatic titrators. Silver nitrate is normally used as titrant (for environmental reasons one should refrain from using mercury nitrate). The titrant concentration depends on the chloride content of the sample to be analyzed. It is crucial to choose the correct electrode for samples with low chloride contents.
- AB-178完全自動の水質分析
電気伝導度、pH値、p値およびm値 (アルカリ度)、塩化物含有量、カルシウムおよびマグネシウム硬度、総硬度、ならびにフッ化物含有量などといったか物理的および化学的パラメータの測定は、水質評価において必要不可欠です。この bulletin では、上記のパラメータを、一度の分析実行でいかに測定できるかが説明されています。水質分析においてさらに重要なパラメータは、過マンガン酸塩指数 (PMI) および化学的酸素要求量 (COD) です。そのため、この Bulletin では、EN ISO 8467に準じたPMIの完全自動測定、ならびにDIN 38409-44に準じたCODの測定についても説明しています。
- AB-221水質分析の標準的な方法
この会報は、水分析の分野からの標準的な方法の調査を提供します。また、それぞれの決定に必要な分析機器と、対応するメトロームアプリケーション速報およびアプリケーションノートへの参照もあります。次のパラメータが処理されます:電気伝導率、pH値、フッ化物、アンモニウムおよびケルダール窒素、イオンクロマトグラフィーによる陰イオンおよび陽イオン、ボルタンメトリーによる重金属、化学酸素需要(COD)、水の硬度、遊離塩素も他のいくつかの水の成分として。
- AB-265Hamilton PRP-X100 IC anion column (6.1005.000)
This Bulletin describes the determination by ion chromatography of anions, particularly fluoride, chloride, nitrite, bromide, nitrate, and sulfate using the Hamilton PRPX100 IC anion column without chemical suppression.
- AN-C-146Bethanechol and HPTA (2-hydroxy-propyl-trimethyl ammonium) besides sodium and calcium (Metrosep C 6 - 250/4.0)
Bethanechol is a pharmaceutical compound which is used to treat urinary retention. This API (active pharmaceutical ingredient) can be determined by cation chromatography with direct conductivity detection. A good separation is achieved between bethanechol and its degradation product 2-hydroxy-propyl-trimethyl ammonium (HPTA) and the standard cations. Peak shape and resolution meet the USP requirements for bethanechol.
- AN-CIC-016燃焼法イオンクロマトグラフィシステムによる石炭中の微量ハロゲン
石炭が燃焼すると、ハロゲンで大気が汚染されます。フッ素と塩素は石炭の自然の構成成分ですが、同様の臭化物は水銀排出を少なくするためにしばしば臭化カルシウムとして投入されます。この 技術資料では、異なる臭化物含有量を示す3つの石炭サンプルを燃焼法イオンクロマトグラフィシステムを使用して燃焼分解の結果を紹介しています。
- AN-CIC-021燃焼法ICによる塩素化および臭素化されたハロブチルゴムに含まれるハロゲンおよび硫黄の測定
ハロブチルゴムに含まれるハロゲンおよび硫黄成分は、燃焼法イオンクロマトグラフィシステムによって分析できます。
- AN-CIC-024ASTM D8150 に則した原油蒸留のナフサフラクションにおける有機塩化物
原油に含まれる有機塩化物の含有量は、蒸留後のナフサフラクションにおいてASTM D8150に則して燃焼法イオンクロマトグラフィシステムを使用して測定されます。
- AN-CIC-027燃焼イオンクロマトグラフィによるポリマー中のハロゲン測定
建築や装飾の用途に使われるポリマー材料は耐炎性が必要です。要求される対炎性の基準に達するため、プレーンポリマーに難燃剤が添加されています。難燃剤にはしばしばハロ有機化合物が用いられます。こういった化合物、および導入されたハロゲンの各濃度は、燃焼イオンクロマトグラフによって測定することができます。全システムのリカバリは認証標準物質 (CRM) によって試験確認済みです。
- AN-CIC-028燃焼イオンクロマトグラフィによる鉄鉱石中のフッ素と塩素の測定
鉄鉱石は、鉄製品にとって重要な資源です。そのハロゲンの自然含有量は、個々のハロゲン化物の腐食による品質特性です。保護バイアルを使用した燃焼イオンクロマトグラフィは、鉄鉱石中のフッ素および塩素の分析に使われます。SO2の放出と、それによる硫黄回収を改善するためにWO3が通常助燃剤として添加されます。このアプリケーションでは、フッ化物の回収も著しく改善させています。
- AN-CIC-032セルロースエステルベースの箔に存在する残留溶媒のインジケータとしての塩化物
セルロースエステル膜は、塩化物溶媒を用いて製造されます。製造に用いられた溶媒残留物は数日で蒸発します。残留溶媒は熱分解熱による有機結合した塩素から塩化物への変換させて、燃焼イオンクロマトグラフフィシステムで測定します。最終製品は塩化物系の溶剤が残っていない状態である必要があります。危険な量のこれらの化合物が残っていないかを品質管理分析において測定することができます。このアプリケーションでは、単一の標準試料から正確な自動キャリブレーションカーブ作成もおこなっています。
- AN-D-001Metrohm IC Driver for OpenLab CDS
This application focuses on the simultaneous analysis of cations and suppressed anions with a dual channel Metrohm IC operated by OpenLab CDS.
- AN-D-002Anions and cations in beer
- AN-D-003Quality control of dialysis concentrates
Ion chromatography (IC) provides an automated, fast, and sensitive solution to accurately quantify cationic and anionic components including acetate simultaneously. This comprehensive approach makes IC an economic alternative to traditional techniques for the quality control of pharmaceutical solutions like haemodialysis concentrates. Ease-of use, accuracy, and the high-throughput of IC increase productivity and comply with the demands of modern routine and research labs.
- AN-H-017Determination of bromide and chloride in photographic developer solutions
Determination of bromide and chloride in photographic developer solutions.
- AN-H-018Determination of chloride in drilling fluids
Determination of chloride in oil well drilling fluids.
- AN-H-033Determination of low levels of chloride in water
Determination of low levels of chloride (to approximately 5 mg/L Cl-) by thermometric titration.
- AN-H-067Determination of chloride in Bayer process liquor
Determination of chloride in Bayer process liquor.
- AN-H-078Determination of total halides in brines
Determination of total halides (Cl- + Br- +I-) in seawater and similar brines. This procedure is suitable for the analysis of total halides in seawater contaminated with sodium aluminate solutions emanating from alumina refineries, and seawater which has been used for the neutralization of alumina refinery waste («red mud») slurries. Given the small concentration of bromine andiodine in seawater, the total halide content approximates the chloride concentration.
- AN-I-006Chloride content of water samples
Determination of chloride in water by direct potentiometry using the Cl-ISE.
- AN-I-015染料に含まれる塩化物含有量の測定
特定の染料の合成において、塩化ナトリウムが副産物として生成されます。そのため、塩化物の含有量は重要なパラメータです。この Application Note では、Cl-イオン選択性電極を用いた標準添加による、染料に含まれる塩化物含有量の測定について説明しています。
- AN-N-003Five anions in solder paste
Determination of anions in solder paste after alcoholic extraction using anion chromatography with direct conductivity detection.
- AN-N-004Fluoride, chloride, bromide, nitrate, and sulfate in organic substances after Schoeniger combustion
Determination of anions in a Schoeniger absorption solution of a test mixture without decomposition of the H2O2 using anion chromatography with direct conductivity detection.