Application Finder
- WP-032Creating Custom Libraries Detection of Binary Explosives with Mira DS
Detection of threatening materials requires robust and sophisticated instruments capable of safe, instantaneous field-analysis of unknowns. In an environment where there is an ever-evolving threat of explosives made from commonlyavailable chemicals, explosive libraries must be customized constantly to include newly targeted materials. Mira DS from Metrohm Raman is the perfect solution for detection of explosives in the field. This handheld Raman instrument is equipped with sophisticated analysis algorithms and a suite of safety features for first responders who need the identity of a potential hazard... NOW! Mira DS and its software can be customized to respond to emerging hazards: this note describes procedures for creating custom libraries of binary explosive precursors to be used in library comparison and mixture matching routines on Mira DS. With these tools, unknown substances can be identified with color-coded warnings for fast action in critical situations.
- 8.000.6087Determination of hexavalent chromium in drinking water according to a U.S. EPA Method
This poster looks at the possibility to modify the existing EPA Method to meet California's rigorous public health goal (PHG) of 0.02 µg/L. After optimizing instrument settings and method parameters, a method detection limit (MDL) of 0.01 µg/L is obtained.
- 410000052-ASee-Through Measurements of Illicit Substances in Commercial Containers with the TacticID®-1064 ST
The TacticID®-1064 ST is a 1064 nm handheld Raman system designed for law enforcement officials, first responders, and customs and border protection officers for rapid field identification of illicit substances such as narcotics, explosives, and other suspicious materials.The TacticID-1064 ST is specially designed with see-through Raman functionality to measure materials through both transparent and opaque containers. These through-barrier measurements remove the need for active sampling of potentially dangerous compounds such as fentanyl, leading to safer operations and reduced wait time for clear results.
- 410000021-APortable Raman Spectroscopy in Forensics: Explosive Residues and Inflammable Liquids
The suitability and potential of Raman spectroscopy in forensics is widely known by forensic specialists who use it in the laboratory to identify a wide variety of compounds including explosives, drugs, paints, textile fibers and inks. However, the use of laboratory-grade Raman outside the laboratory, such as for in‐situ analysis at a crime scene, was something thought possible only in forensic‐fiction until just a few years ago. Fortunately, modern portable Raman spectrometers are commercially available, and their instrumental features are comparable to Raman lab‐ spectrometers.To prove this, some extraordinarily demanding and challenging applications, in which an in‐situ standoff identification of samples might be advisable, were tested.
- AB-404Total acid number titration of petroleum products
The determination of the acid number plays a significant role in the analysis of petroleum products. This is manifested in the numerous standard procedures in use over the world (internal specifications of multinational companies, national and international specifications of ASTM, DIN, IP, ISO, etc.). These procedures differ mainly in the composition of the used solvents and titrants.This bulletin describes the determination of the acid number in petroleum products by applying different types of titration.The potentiometric determination is described according to ASTM D664, the photometric according to ASTM D974 and the thermometric titration according to ASTM D8045.
- AB-061Potentiometric determination of silver – Accurate determination according to EN ISO and GB/T standards
Silver is an important metal not only in jewelry and silverware but also in electrical conductors and contacts. The knowledge of the exact silver content in fine silver and silver alloys ensures that quality standards for jewelry and silverware are met. As for the plating industry, the knowledge of the amount of silver in silver plating baths helps to run the bath efficiently.While X-ray fluorescence (XRF) is a fast alternative to determine the silver content in fine silver and silver alloys, it can only determine the silver content of the outermost sections of the metal. In contrast, titration offers a more comprehensive solution considering the whole sample, thus preventing fraud by thick plating.This application bulletin describes the potentiometric determination of silver in fine silver and silver alloys accordingto EN ISO 11427, ISO 13756, GB/T 17823, and GB/T 18996 as well as in silver plating baths by a titration with potassium bromide or potassium chloride, respectively
- AB-092Potentiometric analysis of lead plating baths
This Bulletin describes the potentiometric determination of lead, tin(II), and free fluoroboric acid.
- AB-101Complexometric titrations with the Cu ISE
This Bulletin describes the complexometric potentiometric titration of metal ions. An ion-selective copper electrode is used to indicate the endpoint of the titration. Since this electrode does not respond directly to complexing agents, the corresponding Cu complex is added to the solution. With the described electrode, it is possible to determine water hardness and to analyze metal concentrations in electroplating baths, metal salts, minerals, and ores. The following metal ions have been determined: Al3+, Ba2+, Bi3+, Ca2+, Co2+, Fe3+, Mg2+, Ni2+, Pb2+, Sr2+, and Zn2+.
- AB-137Coulometric water content determination according to Karl Fischer
This Application Bulletin gives an overview of the coulometric water content determination according to Karl Fischer.Amongst others, it describes the handling of electrodes, samples, and water standards. The described procedures and parameters comply with the ASTM E1064.
- AB-178Fully automated analysis of water samples
The determination of the physical and chemical parameters as electrical conductivity, pH value, p and m value (alkalinity), chloride content, the calcium and magnesium hardness, the total hardness, as well as fluoride content are necessary for evaluating the water quality. This bulletin describes how to determine the above mentioned parameters in a single analytical run.Further important parameters in water analysis are the permanganate index (PMI) and the chemical oxygen deman (COD). Therefore, this Bulletin additionally describes the fully automated determination of the PMI according to EN ISO 8467 as well as the determination of the COD according to DIN 38409-44.
- AB-405Total base number titration of petroleum products
This Application Bulletin shows the determination of the total base number in petroleum products by applying different titration types according to various standards.
- AB-430Determination of uranium by adsorptive stripping voltammetry according to DIN 38406-17
This Application Bulletin describes the methods for the determination of uranium by adsorptive stripping voltammetry (AdSV) according to DIN 38406 part 17. The method is suitable for the analysis of ground, drinking, sea, surface and cooling waters, in which the concentration of uranium is of importance. The methods can, of course, also be used for the trace analysis in other matrices.Uranium is determined as chloranilic acid complex. The limit of detection in samples with low chloride concentration is about 50 ng/L and in seawater about 1 µg/L. Matrices with high chloride content can only be analyzed after reduction of the chloride concentration by means of a sulfate-loaded ion exchanger.
- AB-046Potentiometric determination of cyanide
The determination of cyanide is very important not only in electroplating baths and when decontaminating wastewater but, due to its high toxicity, also in water samples in general. Concentrations of 0.05 mg/L CN- can already be lethal for fish.This Bulletin describes the determination of cyanide in samples of different concentrations by potentiometric titration.Chemical reactions:2 CN- + Ag+ → [Ag(CN)2]-[Ag(CN)2]- + Ag+ → 2 AgCN
- AB-102Conductometry
This bulletin contains two parts. The first part gives a short theoretical overview while more details are offered in the Metrohm Monograph Conductometry. The second, practice-oriented part deals with the following subjects:Conductivity measurements in general; Determination of the cell constant; Determination of the temperature coefficient; Conductivity measurement in water samples; TDS – Total Dissolved Solids; Conductometric titrations;
- WP-061Moisture in petroleum products according to ASTM D6304
Knowledge of the water content in lubricating oils, additives, and similar products is important in the manufacturing, purchase, sale, or transfer of petroleum products to help estimate their quality and performance characteristics. Monitoring the water content in such products can prevent damage to infrastructure and ensure safe operation by avoiding corrosion processes and subsequent engine wear. This White Paper explains the easy determination of moisture in petroleum samples by coulometric Karl Fischer titration according to the three procedures outlined in ASTM Method D6304. A comparison is given between the procedures to determine which is most suitable for different sample types.
- WP-044Fundamentals of Electrochemical Corrosion Research
Free white paper describes the effective use of electrochemical techniques to measure corrosion and the effectiveness of inhibitors.
- WP-027Smart Acquire – Automated Raman Material ID for Defense and Security Professionals
An analytic chemist in your back pocket. A forensic laboratory in a suitcase. A HazMat team in the trunk of your car. First responders need all the help they can get when faced with potentially dangerous substances. Mira DS from Metrohm Raman is a sophisticated chemical analyzer that replaces the specialist with automation. The push of a button initiates proprietary Smart Acquire routines to optimize acquisition parameters and collect the highest quality spectra. These spectra are automatically subjected to library search and Mixture Matching routines capable of identifying up to three components of a mixture. When hazardous substances are detected, the user is alerted to immediate action with color-coded warnings.
- WP-073On-site detection of hexavalent chromium in protective paint primers
It is widely accepted that prolonged exposure to hexavalent chromium compounds can have dire health effects. This has led to increased regulation of chromium-containing products and greater demand for technologies that can positively identify hexavalent chromium in potential matrices. These include paints, dyes, and primers, which can pose a problem for interrogation with Raman, as strongly colored materials often exhibit fluorescence when stimulated at 785 nm. Fluorescence can obscure the Raman signal and prevent positive identification. MIRA XTR DS provides all the functionality of handheld material ID with a new capability that selectively eXTRacts the Raman signal from fluorescent materials. Fluorescence rejection at 785 nm provides higher sensitivity and resolution than 1064 nm systems, as well as a much wider scope of applications amenable to Raman spectroscopy. MIRA XTR DS offers a comprehensive and versatile material ID test solution for field operations.
- 8.000.6020Titrimetric analyses of biofuels
Several testing methods such as the determination of the acid and the iodine numbers in biodiesel as well as the quantification of sulfate and chloride in bioethanol are described.
- 8.000.6077Determining the water content in biodiesel by Karl Fischer titration as per EN ISO 12937
This poster describes the water determination in different biodiesel samples via direct coulometric titration, the Karl Fischer oven method and an automated KF pipetting system.
- 410000024-BRaman solution suite for forensics applications
Law enforcement personnel, laboratory technicians, crime scene investigators and many others face a significant challenge for identification of materials in a forensic investigation.Traditionally, technicians used multiple forms of identification in order to collect results from various forms of forensic samples. Although certain technologies are ideal for precise laboratory identification, many technologies, such as Raman spectroscopy, can be successfully used for identification of multiple forensic sample types either directly in the field or in the lab. Raman spectroscopy is classified as a Category A analytical method by the Scientific Working Group for the Analysis of Seized Drugs (SWGDRUG; Version 7.1, 2016).
- AB-089Potentiometric analysis of anodizing baths
This Bulletin describes potentiometric titration methods for checking sulfuric acid and chromic acid anodizing baths. In addition to the main components aluminum, sulfuric acid, and chromic acid, chloride, oxalic acid, and sulfate are determined.
- AB-130Chloride titrations with potentiometric indication
Potentiometric titration is an accurate method for determining chloride content. For detailed instructions and troubleshooting tips, download our Application Bulletin.
- AB-077Volumetric water content determination according to Karl Fischer – Tips and tricks for volumetric Karl Fischer titration
This Application Bulletin gives an overview of the volumetric water content determination according to Karl Fischer. Amongst others, it describes the handling of electrodes, samples, and water standards. The described procedures and parameters comply with the ASTM E203.
- AB-090Potentiometric analysis of tin plating baths
Potentiometric titration methods for the analysis of acid and alkaline tin plating baths are presented. The following methods are described: tin(II) / tin(IV) / total tin, free fluoroboric acid, or free sulfuric acid, chloride in acidic tin baths, free hydroxide, and carbonate in alkaline tin baths.
- AB-110Determination of free cyanide by polarography
This Application Bulletin describes a polarographic method for the determination of cyanide that allows to determine free cyanide fast and accurately. The determination also succeeds in solutions containing sulfides, where other methods fail. Cyanide concentrations in the range b(CN–) = 0.01...10 mg/L cause no problems. Interference caused by anions and complexed cyanides has been investigated.
- AB-135Potentiometric determination of hydrogen sulfide, carbonyl sulfide, and mercaptans in petroleum products
This Bulletin describes the potentiometric determination of hydrogen sulfide, carbonyl sulfide, and mercaptans in gaseous and liquid products of the oil industry (natural gas, liquefied petroleum gas, used absorption solutions, distillate fuels, aviation gasoline, gasoline, kerosene, etc.). The samples are titrated with alcoholic silver nitrate solution using the Ag Titrode.
- AB-249Determination of free and residual chlorine based on DIN EN ISO 7393-1 and APHA 4500-Cl
Chlorine is frequently added to drinking water for disinfection. Depending on the reactivity and the concentration of chlorine, toxic disinfection by-products (DBPs) can thereby be released. Therefore, it is necessary to strictly control the chlorine concentration in the drinking water. This Application Bulletin shows how to determine the chlorine concentration according to three standard methods: DIN EN ISO 7939-1, APHA 4500-Cl Method B, and APHA 4500-Cl Method I.
- AB-063Silicon, calcium, magnesium, iron and aluminum in cement after digestion and photometric titration
As much as the many types of cement may differ from one another, the characteristic that all of them have in common is the presence of the elements calcium, magnesium, iron, aluminum and silicon.Calcium, magnesium, iron and aluminum can be determined using various indicators following digestion of the cement sample using photometric titration with the Optrode at 610 nm. The determination of silicon, on the other hand, is gravimetric.
- AN-NIR-064Quality control of ammonium nitrate
Specialty chemicals have to fulfill multiple quality requirements. One of these quality parameters, which can be found in almost all certificates of analysis and specifications, is the moisture content. The standard method for the determination of moisture content is Karl Fischer titration.This method requires reproducible sample preparation, chemicals, and waste disposal. Alternatively, near-infrared spectroscopy (NIR) can be used for the determination of moisture content. With this technique, samples can be analyzed without any preparation and without using any chemicals.
- AN-RS-012Handheld Raman for Acid Attack Prevention
Acid throwing, a historical method for retribution against women, has become a modern threat of a different nature. Concentrated acids and other corrosive substances have emerged as modern tools of social violence. Aggressors use common plastic containers with openings that create a powerful directional spray, such as lemon juice squeeze bottles. Sulfuric and phosphoric acids were chosen for analysis here due to their highly corrosive nature- acid attacks in London most commonly use sulfuric, phosphoric, and nitric acids.2017 saw a remarkable number of acid attacks in the UK, with reported incidences averaging 2x a day. Detection and regulation of acids may contribute to prevention of this social scourge.
- AN-C-135Cations in drinking water using Metrosep C 4 - 150/4.0 column according to ISO 14911.
Drinking water analysis is strongly regulated by standards. In this Application Note, the cation determination according to ISO 14911 is shown. The Metrosep C 4 - 150/4.0 is the optimum separation column for this purpose.
- AN-I-030Dissolved oxygen in tap water
In municipal water supplies, higher dissolved oxygen (DO) content is desirable because it improves the taste of drinking water. However, high DO levels also speed up corrosion in water pipes. For this reason, industries utilize water with as little DO as possible, and add scavengers such as sodium sulfite to remove any oxygen from a water supply. Municipal water supply pipes are normally coated inside with polyphosphates to protect the metal from contact with oxygen, thus allowing higher DO contents. Therefore, monitoring the DO content online in a water supply is important to assess its DO content to either improve taste or minimize pipe corrosion. Using an optical sensor, such as the O2-Lumitrode, allows a fast and reliable determination according to ISO 17289.
- AN-K-009Water in explosive pellets
The water content of explosive pellets is determined according to Karl Fischer after extraction with methanol.
- AN-K-013Water in organic peroxides
The water content of organic peroxides is determined according to Karl Fischer using two-component reagents. To prevent any unwanted side reactions, the determinations are carried out at -20 °C.
- WP-012Corrosion control: Thermometric TAN analysis in oil & refinery distillation fractions
Many refiners look at discounted opportunity crudes as a means to improve their margin spread. The varieties of these cheap crude oils on the market are growing in number, but they have hidden risks for the purchaser caused by factors such as high naphthenic acid and sulfur content. Sulfur compounds and naphthenic acids are among the substances that contribute to the corrosive nature of crude oils and petroleum products. This is why the risk of corrosion is increased when processing crude oils with high naphthenic acid and sulfur content. The refiner must balance the cost benefit versus the risk and the cost of corrosion control when processing these crudes. A reliable acid number determination is a crucial part of corrosion control. Guest authors Bert Thakkar, Bryce McGarvey, and Colette McGarvey of Imperial Oil and Larry Tucker and Lori Carey of Metrohm USA were involved in the development of the new ASTM Method D8045 for acid number determination. Here, they report on the method and how it came to be.
- WP-072Fluorescence-free 785 nm material ID with MIRA XTR DS
In this White Paper, you will learn about MIRA XTR DS – the smallest, smartest, most flexible handheld Raman system with the largest libraries available on the market! MIRA XTR DS has all the benefits of 785 nm Raman interrogation: compact size, low laser power, sample preservation, long battery lifetimes... now with fluorescence rejection. Additionally, there is improved sensitivity and resolution over 1064 nm systems. This opens up new possibilities for 785 nm Raman, including strongly colored materials, common excipients, illicit materials, and more.
- BWT-4910The Use of Portable and Handheld Raman for Forensic Investigations
Today's Raman instrumentation is faster, more rugged, and less expensive than in the past and the advances in component miniaturization have led to the design of portable devices with extremely high performance designed for field-based investigations. This study focuses on the use of handheld Raman spectroscopy for the characterization and identification of samples encountered in various application areas related to forensic science.
- 410000054-ATechnical Note: Method Development with NanoRam®-1064
Although the process of building, validating and using a method is well-defined through software, the robustness of the method is dependent on proper practice of sampling, validation, and method maintenance. In this document, we will detail the recommended practices for using the multivariate method with NanoRam-1064. These practices are recommended for end users who are in the pharmaceutical environment, and can expand to other industries as well. This document aims to serve as a general reference for NanoRam-1064 users who would like to build an SOP for method development, validation and implementation.
- AB-093Potentiometric analysis of cadmium plating baths
This Bulletin describes titrimetric methods for the determination of cadmium, free sodium hydroxide, sodium carbonate, and total cyanide. The free cyanide can be calculated from the total cyanide and the Cd content.
- AB-091Potentiometric analysis of brass and bronze plating baths
Methods are described for the potentiometric analysis of the following bath components:Brass plating bath: copper, zinc, free cyanide, ammonium, carbonate, and sulfite.Bronze plating bath: copper, tin, and free cyanide.
- AN-M-002Chlorite, chlorate, and perchlorate in explosion residue using IC/MS coupling
Determination of chlorite, chlorate, and perchlorate in explosion residue using anion chromatography with conductivity and MS detection in tandem.
- AB-427Acid number in petroleum products with thermometric titration
This Application Bulletin describes the determination of the total acid number in various oil samples by catalytic thermometric titration as per ASTM D8045.
- AB-125Simultaneous determination of calcium, magnesium, and alkalinity by complexometric titration with potentiometric or photometric indication in water and beverage samples
This bulletin describes the determination of calcium, magnesium, and alkalinity in water by complexometric titration with EDTA as titrant. It is grouped into two parts, the potentiometric determination and the photometric determination.There are multiple definitions of the different types of water hardness. In this Application Bulletin, the following definitions are used: alkalinity, calcium hardness, magnesium hardness, total hardness, and permanent hardness. Explanations of these definitions and other expressions are provided in the Appendix.Determination of alkalinity during the photometric part is carried out in a separate acid-base titration before the complexometric titration of calcium and magnesium in water. Permanent hardness can be calculated from these values. The determination of calcium and magnesium in beverages (fruit and vegetable juices, wine) is also described.The photometric part includes the determinations of total and calcium hardness and thereby indirectly magnesium hardness using Eriochrome Black T and calconcarboxylic acid as indicators (in accordance with DIN 38406-3).
- AN-RS-046Through-container analysis with Raman spectroscopy
TacticID-1064 ST is a handheld Raman device that can identify materials through paper, plastic, glass, and multilayer packaging, reducing exposure risks and eliminating the need to open containers.
- AN-R-010Oxidation stability of biodegradable lubricating oil
The oxidation stability of biodegradable lubricating oil is determined using the Rancimat method.
- AN-R-034Oxidation stability of diesel, biodiesel, and blends
Sustainable biodiesel can be blended with petroleum diesel. The 893 Professional Biodiesel Rancimat measures the oxidation stability of biodiesel and its blends.
- AN-S-041Sulfate in diesel engine coolant using dialysis for sample preparation
Determination of sulfate in diesel engine coolant using anion chromatography with conductivity detection after chemical suppression and dialysis for sample preparation.
- AN-S-328Sulfate in addition to chromate in bright chrome baths
Chrome plating is an important electroplating technique that covers metal or plastic surfaces with a thin layer of chromium for both protection and decoration purposes. The sulfate and sulfuric acid concentrations in the baths are important parameters in the coating process and require continuous monitoring. The anions in the chrome baths are separated on the Metrosep A Supp 5 - 250/4.0 column and are determined using conductivity detection in accordance with sequential suppression.
- AN-S-206Online monitoring of trace anions in boiler feed water
Determination of trace levels of chloride, nitrate, phosphate, and sulfate in a boiler feed water using anion chromatography with conductivity detection after chemical suppression.