Filtro de Aplicações
- AB-420Determination of suppressor with CVS using the calibration technique «smartDT» with dynamic addition volumes
The Application Bulletin describes the determination of suppressor in acid copper baths by smartDT. The determination of suppressor with dilution titration (DT) involves numerous additions with standard solution or sample to reach the evaluation ratio. Usually fixed, equidistant addition volumes are used. With smartDT, variable addition volumes are used that are dynamically calculated by the software. At the beginning, the volumes are bigger. Towards the evaluation ratio, the addition volume becomes smaller to guarantee a good accuracy of the result. The operator defines the first and the smallest addition volume to be used. All volumes in between are calculated by the software considering the progress of the determination. The time saving with smartDT compared to a classic DT with fixed addition volumes can be up to 40%. smartDT is suitable for nonlinear regression and quadratic regression as well as linear interpolation. It can be used for determination of suppressor in acid copper baths as well as in tin and tin-lead baths and works with 1, 2, and 3 mm Pt working electrodes. A 800 Dosino is required for the automatic addition of suppressor standard or sample. The method can also be used in fully automated systems.
- AN-EC-030Electrochemistry of microelectrodes: a comparison with common-size electrodes
In this Application Note, the electrochemical properties of electrodes with a micrometer-size surface area are compared with the electrochemical properties of electrodes with millimeter-size surface area. The comparison is made through cyclic voltammetry in a Fe3+/Fe2+ (ferro/ferri) solution, and the differences in the voltammograms are explained with the different diffusion profiles at the electrode-electrolyte interface.
- AN-PAN-1067Online analysis of organic additives in copper plating process
Monitoring organic additives in copper plating baths is crucial. The 2060 CVS Process Analyzer optimizes copper electroplating by providing precise bath control.
- AN-V-133Suppressor «Copper Gleam 2001 Carrier» (Rohm and Haas) in acid copper bath
Determination of suppressor «Copper GleamTM 2001 Carrier» in acid copper baths by dilution titration (DT) using cyclic voltammetric stripping (CVS).
- AN-V-134Brightener «Copper Gleam 2001 Additive» (Rohm and Haas) in acid copper bath
Determination of brightener «Copper GleamTM 2001 Additive» in acid copper baths by modified linear approximation technique (MLAT) using cyclic voltammetric stripping (CVS).
- AN-V-135Suppressor «Cupracid BL-CT» (Atotech) in acid copper bath
Determination of suppressor «Cupracid BL-CT» in acid copper baths by dilution titration (DT) using cyclic voltammetric stripping (CVS).
- AN-V-136Brightener «Cupracid BL» (Atotech) in acid copper bath
Determination of brightener «Cupracid BL» in acid copper baths by linear approximation technique (LAT) using cyclicvoltammetric stripping (CVS).
- AN-V-137Suppressor «Cupraspeed» (Atotech) in acid copper bath
Determination of suppressor «Cupraspeed» in acid copper baths by dilution titration (DT) using cyclic voltammetric stripping (CVS).
- AN-V-138Brightener «Cupraspeed» (Atotech) in acid copper bath
Determination of brightener «Cupraspeed» in acid copper baths by modified linear approximation technique (MLAT)using cyclic voltammetric stripping (CVS).
- AN-V-141Suppressor «MACuSpec PPR 100 Wetter» Wetter (MacDermid) in acid copper bath
Determination of suppressor «MACuSpecTM PPR 100 Wetter» in acid copper baths by dilution titration (DT) using cyclic voltammetric stripping (CVS).