- WP-037Simplifying quality control using Near-Infrared Spectroscopy
Quality control is impacted by multiple challenges, which can have an influence on the functioning of the QC lab. The present White Paper provides approaches, how to simplify the daily quality control using near-infrared spectroscopy combined with a dedicated smart software like Vision Air.
- WP-045When HPLC fails: IC in food, water, and pharmaceutical analysis
High-Performance Liquid Chromatography (HPLC) and Ion Chromatography (IC) are commonly used in the pharma, food, and environmental sectors to analyze samples for specific components and to verify compliance with norms and standards. However, users of HPLC may run into the limitations of this technique, e.g., when analyzing standard anions or certain pharmaceutical impurities. This white paper outlines how such challenges can be overcome with IC.
- WP-017Near-infrared spectroscopy in pharmacopoeias
The pharmaceutical industry is very likely more comprehensively regulated that any other branch of industry. It therefore requires analytic methods that meet the requirements of regulations while at the same time being practical. This applies in particular for large sample quantities, such as are encountered with incoming goods inspections, for example. It is here that particularly rapid and simple analysis methods are called for which make routine analyses simpler and more efficient. This White Paper describes some of the most important regulations in the pharmaceutical analysis and shows how Vis-NIR spectroscopy can solve analytic problems in the pharmaceutical industry in accordance with regulations.
- WP-019Ion chromatography – a universal technique with many applications in the pharmaceutical industry
Ion chromatography is a flexible technique with a large selection of intended uses in the pharmaceutical industry. – A few development trends and the latest advances are displayed here.
- WP-042Data Integrity with NIR-Spectroscopy Software
Data Integrity is currently a hot topic issue that has created much attention and has raised concern within companies working in regulated environments. This White Paper explains some of the key terms used in the context of Data Integrity and outlines how the requirements of Data Integrity can be understood and implemented.
- WP-018FDA 21 CFR Part 11 Requirements for NIR Spectroscopy
This Metrohm White Paper shows the requirements demanded of the pharmaceutical industry by the FDA with respect to software products. Implementation examples of the regulations formulated by the FDA in 21 CFR Part 11 are presented using Vision Air Pharma Software.Key words: electronic signatures, audit trails, user management, documentation
- WP-031Lifecycle of multivariate methods according to United States Pharmacopeia Chapter <1039> Chemometrics
Chemometrics is a powerful tool widely used for method development in the pharmaceutical industry. This whitepaper describes the lifecycle of multivariate models and summarizes the workflow of the development of chemometrical models according to the new USP chapter <1039>.
- WP-043Instrument Calibration, System Verification, and Performance Validation for Metrohm Instant Raman Analyzers (Mira)
Analytical Instrument Qualification (AIQ) according to the United States Pharmacopeia (USP) ensures that instruments perform as intended and users may have confidence in data quality. As the Pharma industry adopts handheld Raman instruments for incoming materials identification and verification, producers of such systems must provide suitable calibration and validation routines. Upon completion of these tests, end users are assured that all measurements are in accordance with agreed standards at Metrohm Raman, we have sophisticated AIQ routines in place to confirm the quality of your results.
- WP-049Your IC results are only as good as your sample vials
Polymeric sample vials are frequently contaminated with leachable organic or inorganic ions, which originate from the production process or the raw material. These substances can falsify measurement results. The study at hand compares the leaching properties of several vial types from different manufacturers, showing considerable variations in quality and proving the importance of the right choice of vials for ion chromatography (IC). This white paper also provides recommendations and precautions to further reduce leachable contaminants for IC trace analysis.
- WP-063Recommendations for converting a manual titration procedure into an automated titration procedure
This white paper summarizes the steps involved in converting an existing manual titration procedure to semi-automated or automated titration procedures. It discusses topics such as selecting the right electrode and titration mode. For a better understanding, the discussion topics are illustrated with three examples.
- WP-074Determination of polyribosylribitol phosphate (PRP) in Haemophilus influenzae vaccine using ion chromatography with pulsed amperometric detection
Haemophilus influenzae type B (Hib) is a major cause of bacterial meningitis in children in many countries. The capsular polysaccharide (PS) of Hib plays an important role in the virulence of the organism. The polysaccharide capsule hides cell surface components from elements of the mammalian immune system, such as antibodies and complement proteins that otherwise would activate mechanisms to kill the pathogen. Vaccines require rigorous characterization and assays to ensure final product quality and consistency. For glycoconjugate vaccines, it is important to measure both free and total PS to ensure the quality. A large amount of unconjugated PS may suppress immunity to the antigen. Additionally, the presence of free PS is a key indicator of process consistency. Current methods to determine PS content in vaccines such as Hib are imprecise and unreliable, especially if the vaccine contains a sugar stabilizer (e.g. lactose). Ion chromatography with pulsed amperometric detection (IC-PAD, or HPAEC-PAD) offers a simpler procedure and better sensitivity than other assays to quantify PS (here, polyribosylribitol phosphate [PRP]) in Hib vaccine.
- WP-092USP monograph modernization initiative leading to modern ion chromatography-based methods
The USP and FDA started to modernize several monographs and General Chapters. In many cases, IC-focused methods have replaced older, wet chemistry procedures. Learn more about the USP modernization initiative and the advantages of ion chromatography in this white paper.
- 8.000.6024Fully automated sample preparation for the content determination of tablets
Benzbromaron is one of the main uricosuric drugs currently used. In addition to sophisticated and expensive LC-MS and GC-MS methods, benzbromaron can be effectively determined by titration with sodium hydroxide solution using a straightforward, fully automated sample preparation method. A high-frequency homogenizer comminutes one or three tablets within 90 or 120 s respectively. The overall analysis time is 8 minutes. Ten-fold determinations with one and three tablets resulted in a benzbromaron content of 99.2 and 98.7 mg per tablet respectively. Increasing the number of tablets from one to three lowers the RSD from 1.36 to 0.88%. These results show an excellent agreement with the benzbromaron content indicated by the manufacturer (approx. 100 mg/tablet).Besides the presented Titrando/homogenizer combination, the other two members of the 815 Robotic Soliprep Sample Processor family offer comprehensive sample preparation possibilities within the fields of IC, HPLC, ICP or voltammetry.
- 8.000.6106Potassium Assay in OTC Drug Products by Ion Chromatography
This poster presented jointly with USP at AAPS meeting shows, that we successfully developed and validated a single IC procedure for potassium assay and identification in potassium bicarbonate and potassium chloride for effervescent oral suspension. The optimized chromatographic conditions could be used for other cationic impurities, such as magnesium, calcium, sodium, and ammonium in potassium bicarbonate and potassium chloride for effervescent oral suspension. Single chromatographic method for assay and identification simplifies the overall QA/QC workflow.
- 8.000.6110Fluoride in OTC Products by Ion Chromatography
Fluoride is commonly used in dental products to help prevent tooth decay. When fluoride is present in high concentrations, these products are regulated by 21 CFR 355. Three fluoride compounds used in over the counter (OTC) anti‐cavity dental products are sodium fluoride, stannous fluoride and sodium monofluorophosphate (MFP). The assay of fluoride in these active ingredients and finished formulations are determined by manual titration, or by ion‐selective electrodes. As a part of USP’s global monograph modernization initiative, an alternative selective and sensitive method has been developed and validated – ion chromatography (IC). The proposed IC method can also be used for the identification test as an alternative to the wet chemistry method.
- 8.000.6102Ion chromatography – the all-rounder for pharmaceutical analysis
Pharmaceutical analysis guarantees drug safety by providing information on the identity, content, quality, purity, and stability of pharmaceutical products using analytical chemistry. Ion chromatography (IC) offers a broad range of pharmacopeia-compliant applications for quality control, monitoring, and improving drug manufacturing.As a very accurate and versatile technique, IC meets the requirements of many pharmaceutical applications. IC is a USP-accepted standard method for the determination of active pharmaceutical ingredients (APIs), excipients, impurities,pharmaceutical solutions as well as pharmaceutical starting materials, finished pharmaceutical products (FPPs) and even body fluids.This poster describes some typical examples.
- 8.000.6010Inline sample preparation – An effective tool for ion analysis in pharmaceutical products
By means of azide analysis in Irbesartan a simple, fast, precise and accurate ion chromatographic method for the determination of traces of inorganic contaminants in pharmaceuticals is described. Traces of toxic azides in pharmaceutical products can accurately be determined in the sub-ppb range after Metrohm Inline Matrix Elimination using isocratic ion chromatography (IC) with suppressed conductivity detection. While the azide anions are retained on the preconcentration column, the interfering pharmaceutical matrix is washed away by a transfer solution, ideally consisting of 70% methanol and 30% ultrapure water. The analytical setup provides a well-resolved azide peak and thus alleviates the common drawback of excipient interferences, especially from the nitrate anion. Calibration with azide standards is linear over the range of 5…80 ppb, providing a coefficient of determination of 0.9995. The limit of detection (LOD) and the limit of quantification (LOQ) of azide in Irbesartan are 5 and 30 µg/L respectively; the relative standard deviations (RSD) for the peak area, peak height and retention time being smaller than 3.9%. Robustness testing involved variation of column oven temperature and composition of the transfer solution and, in terms of peak area, provided RSDs smaller than 2.8% and 3.1% respectively.
- 8.000.6051PC-controlled dosing and liquid handling
The 800 Dosino controlled by tiamo™ or Touch Control can be used universally for dosing and liquid handling tasks in both the analytical laboratory or directly in the synthesis laboratory. This poster looks at three typical liquid handling applications, the synthesis of metal-organic compounds, the preparation of standards, and the determination of pharmaceutical ingredients.
- 8.000.6078Water determination in pharmaceuticals using an automated Karl Fischer Oven Technique
The poster describes the water determination in pharmaceuticals using the Karl Fischer oven technique.
- 8.000.6026Determination of the water content in tablets by automated Karl Fischer titration
The water content of tablets determines the release of their active ingredients as well as their chemical, physical, microbial and shelf-life properties. Accordingly, the water content is of crucial importance and has to be accurately determined. This paper describes the straightforward determination of the water content using automated volumetric Karl Fischer titration (KFT). Tedious sample preparation steps are eliminated by using a high-frequency homogenizer that additionally serves as a stirrer. Prior to titration, the homogenizer comminutes the tablets directly in the KF solution. As the comminution process takes place directly in the hermetically sealed titration vessels, interference from atmospheric humidity does not occur. Even after 24 h in the vessels, the moisture content of four different tablet type samples was within 93…108% of the initially determined values. With a coefficient of determination of 0.99993 the KF method is highly linear for water amounts between 4 and 215 mg. For all investigated tablet types, KFT provides results that lie within the range expected by the manufacturer.
- 410000030-APortable Transmission Raman Spectroscopy for At-Line Content Uniformity Testing of Pharmaceutical Tablets
Analytical methods to perform CU testing should ideally be fast, noninvasive and achieved with limited sample preparation. Recently, transmission near-infrared (NIR) spectroscopy and transmission Raman spectroscopy have both been explored as alternative methods for rapid and non-destructive on- and at-line CU testing with no sample preparation. Although quick and nondestructive, transmission NIR spectroscopy suffers from poor chemical selectivity and is sensitive to changes in the testing environment. Transmission Raman spectroscopy combined with chemometric modeling is quickly emerging as a valued technique for CU testing due to its high chemical specificity, which is particularly useful when dealing with complex pharmaceutical formulations that contain multiple components.
- 410000039-AQuantitative Analysis of Solutions Using a High Resolution Portable Raman Spectrometer
Ternary mixtures of aqueous sugar solutions are measured and multivariate models of the concentration of analytes developed using BWIQ software.
- AB-181Automatic potentiometric titration of aluminum and magnesium in the same solution
Mixtures of aluminum and magnesium ions can be analyzed automatically using potentiometric titration. The excess DCTA is back-titrated with copper(II) sulfate solution after the addition of 1,2-diaminocyclohexanetetraacetic acid (DCTA) and complex formation. The ion-selective copper electrode is used here as the indicator electrode. First, the aluminum is determined in acidic solution and then the magnesium in alkali solution.
- AB-199Determination of sulfide and sulfite by polarography
Sulfide and sulfite can be determined polarographically without any problems. For sulfide, polarography is performed in an alkaline solution, for sulfite in a slightly acidic primary solution. The method is suitable for the analysis of pharmaceuticals (infusion solutions), wastewater/flue gas water, photographic solutions, etc.
- AB-213Determination of nicotinamide by polarography
This Application Bulletins describes the determination of nicotinamide (vitamin PP), a vitamin of the B series. Instructions for the determination in solutions (e.g. fruit juice), vitamin capsules and multivitamin tablets are given. The linearity range of the determination is also specified. The limit of detection is approximately 50 μg/L nicotinamide.
- AB-250Polarographic determination of diazepam in body fluids and pharmaceutical preparations
Diazepam belongs to the 1,4-benzodiazepine group of compounds, which are used for medical purposes as tranquilizers and antidepressants. This Bulletin describes the determination of diazepam in tablets and body fluids (blood, serum, urine) by means of differential pulse polarography. If a Britton-Robinson buffer pH = 2.8 with a methanol volume fraction of 20% is used as the supporting electrolyte then a pronounced reduction peak is obtained at -0.73 V; this allows diazepam concentrations even below 0.05 µg/mL to be determined in blood. The necessary sample preparation steps are also dealt with in this Bulletin.
- AB-268Potentiometric titration of surfactants and pharmaceuticals – an overview
The present Bulletin offers an overview of the multitude of surfactants and pharmaceuticals that can be determined with potentiometric titration. Metrohm provides five different surfactant electrodes for indicating the titration endpoint: the Ionic Surfactant, the High Sense, the Surfactrode Resistant, the Surfactrode Refill and the NIO Surfactant electrode. The manufacture of the respective titrants and their titer determination are described in detail. In addition to this, the Bulletin contains a tabular overview of more than 170 proven applications from the area of surfactant and pharmaceutical analysis. This guideline leads you reliably to your destination: At a glance you can see from the table which surfactant electrode and which titrant are optimally suitable for your product.
- AB-280Automatic Karl Fischer water content determination with the 874 Oven Sample Processor
Generally speaking, the gas extraction or oven method can be used for all samples which release their water when they are heated up. The oven method is indispensable in cases in which the direct volumetric or coulometric Karl Fischer titration is not possible, either because the sample contains disruptive components or because the consistency of the sample makes it very difficult or even impossible to transfer it into the titration vessel.The present Application Bulletin describes automatic water content determination with the aid of the oven technique and coulometric KF titration, using samples from the food, plastic, pharmaceutical and petrochemical industry.
- AB-074Determination of antimony, bismuth, and copper by anodic stripping voltammetry
This Application Bulletin describes the voltammetric determination of the elements antimony, bismuth, and copper. The limit of detection for the three elements is 0.5 ... 1 µg/L.
- AB-098Determination of ascorbic acid (Vitamin C) and its compounds
In addition to its natural occurrence in fruit and vegetables, ascorbic acid (Vitamin C) is used as an antioxidant in foods and drinks. Ascorbic acid is furthermore also to be found in numerous drugs.Ascorbic acid and its salts and esters can be determined with titration or by using polarography, for which ascorbic acid is oxidized to form dehydroascorbic acid.Bi-voltammetric or photometric equivalence point indication can be used for titrimetric determination. It must be taken into account here that only bi-voltammetric indication is independent of the inherent color of the sample. Polarography is the most selective of the methods described, as other reducing or oxidizing substances are not recorded.
- AB-101Complexometric titrations with the Cu ISE
This Bulletin describes the complexometric potentiometric titration of metal ions. An ion-selective copper electrode is used to indicate the endpoint of the titration. Since this electrode does not respond directly to complexing agents, the corresponding Cu complex is added to the solution. With the described electrode, it is possible to determine water hardness and to analyze metal concentrations in electroplating baths, metal salts, minerals, and ores. The following metal ions have been determined: Al3+, Ba2+, Bi3+, Ca2+, Co2+, Fe3+, Mg2+, Ni2+, Pb2+, Sr2+, and Zn2+.
- AB-137Coulometric water content determination according to Karl Fischer
This Application Bulletin gives an overview of the coulometric water content determination according to Karl Fischer.Amongst others, it describes the handling of electrodes, samples, and water standards. The described procedures and parameters comply with the ASTM E1064.
- AB-219Determination of riboflavin (vitamin B2) by polarography
This Application Bulletin describes the polarographic determination of riboflavin (vitamin B2). The procedure allows an analysis in monovitamin preparations. The limit of determination is approx. 100 μg/L.
- AB-215Determination of folic acid by polarography
This Application Bulletin describes the polarographic determination of folic acid, a vitamin of the B series, also known as vitamin B9 or vitamin BC. Instructions for the determination in solutions (e.g. fruit juice), vitamin capsules and multivitamin tablets are given. The linear range of the determination is also specified. The limit of detection is approx. 75 µg/L folic acid.
- AB-251Polarographic determination of cinchocaine (dibucaine) in pharmaceutical preparations
Cinchocaine (dibucaine) is used in the form of ointments or injection solutions as a local anaesthetic. Its base is soluble in diethyl ether; its hydrochloride, on the other hand, is insoluble in diethyl ether but easily soluble in water. This Bulletin describes the determination of cinchocaine in ointments, creams and injection solutions by means of differential pulse polarography. An acetate buffer pH = 4.8 is used as the supporting electrolyte. The limit of quantitation and the linear working range of the method are given. The necessary sample preparation steps are also dealt with in this Bulletin.
- AB-410Pharmaceutical analysis using near-infrared spectroscopy
The present Application Bulletin contains NIR applications and feasibility studies using NIRSystems devices in the pharmaceutical industry. Qualitative and quantitative analyses of a wide variety of samples are part of this bulletin. Each application describes the instrument that was originally used for the analysis, as well as the system recommended for the analysis and the results that were achieved thereby.
- AB-417Automated volumetric Karl Fischer titration using MATi 11
MATi 11 (MATi = Metrohm Automated Titration) is a completely configured system for water content determination in solid or liquid samples using automated volumetric Karl Fischer titration. It contains a Polytron PT 1300 D for the homogenization of the samples. Up to 53 samples are analyzed directly in 120 mL titration beakers. The samples are weighed in the titration beaker and sealed with aluminum foil and a foil holder so that they neither lose nor absorb water.
- AB-428Automatic conductometry in water samples with low electrical conductivity in accordance with USP<645>
This Bulletin describes the automatic measurement of conductivity in water samples with low electrical conductivity in accordance with USP<645>. Conductivity measurement is demonstrated on the example of ultrapure water, which is used, among other things, to produce injection solutions in the pharmaceutical sector.
- WP-040Benefits of Client-Server Systems for Quality Control with Vis-NIR Spectroscopy
Analyzer systems monitoring product quality can offer substantial advantages when organized in a client-server network compared to the more traditional local installation. This white paper presents different client-server setups and their benefits. Security aspects that need to be considered are discussed based on the example of the client-server Vis-NIR (visible near-infrared) spectroscopy software Vision Air, widely used for quality control in the chemical, polymer, pharmaceutical, and petrochemical industry.
- WP-068Recommendations for titration methods validation
The objective of validation of an analytical procedure is to demonstrate that it is suitable for its intended purpose. Recommendations for the validation of analytical methods can be found in ICH Guidance Q2(R1) Validation of Analytical Procedures: Text and Methodology and in USP General Chapter <1225> Validation of Compendial Procedures. The goal of this white paper is to provide some recommendations for the validation of titration methods.
- 8.000.6089Automated sample measurement in Karl Fischer titration
This poster describes a method for automated and precise dosing of liquid samples into the Karl Fischer titration cell using Metrohm Dosino liquid handling technology. First, the titer was automatically determined with ultrapure water. The same dosing procedure proved valuable for the automated water determination in highly viscous water-glycol fluids and low-boiling organic solvents such as n-pentane. Lastly, the method copes with the labor-intensive and human error-prone suitability test stipulated in chapter 2.5.12 in the European Pharmacopoeia.
- TA-052IC-ICP-MS analysis of iodized X-ray contrast media
On the basis of the experiments that have been performed, it is possible to determine the effectiveness of the ozonization of iodized X-ray contrast media using IC-ICP-MS via the amount of iodate formed. Whereas a 120-minute ozonization guarantees a practically quantitative decomposition of amidotrizoic acid to iodate, approximately 16% of the Iomeprol is still present under the same ozonization conditions. Given that only 14% is present in iodate form in the absence of iodide anions and given that additional, not yet identified peaks occur in the ion chromatogram, the presence of additional decomposition products containing iodine must be assumed. Nonetheless, it is not possible to detect the intact iodized X-ray contrast media with the selected ion chromatographic conditions. Furthermore, the possibility exists of identifying the peak of the unknown decomposition product of the Iomeprol using IC-ESI-TOF-MS.
- TA-023Investigation of MRT contrast media containing gadolinium by means of IC-ICP/MS analysis
This article describes the investigation using ion chromatography and subsequent inductively coupled plasma mass spectronomy (ICP/MS) to determine the extent to which the iron(III) flocculation carried out in the context of wastewater treatment releases toxic gadolinium(III) ions as the result of recomplexing.
- 410000046-AQTRam® for Content Uniformity Analysis of Low-Dose Pharmaceutical Tablets
In this note, we use a model drug, acetaminophen, to demonstrate the capability of QTRam® to quantify low concentrations of API in compressed tablets.QTRam® is a compact transmission Raman analyzer designed specifically for content uniformity analysis of pharmaceuticals in solid dosage forms.
- BWT-4906Rapid Raw Material Identification for Formulation Compounds Using Handheld Raman Technology
The raw materials whey, sorbitol, stearic acid, and calcium phosphate dihydrate dibasic all show very distinctive, unique Raman signatures, which indicates that Raman spectroscopy is the ideal technology for identification of these materials. The PCA model-based method provides reliable specificity to successfully identify these nondestructively in plastc samples bags using the NanoRam.
- BWT-4915Portable, High-Efficiency Transmission Raman Spectroscopy for At-Line Content Uniformity Testing of Pharmaceutical Tablets
Content uniformity of solid dosage forms can be done nondestructively at the process line using the QTRam portable transmission Raman system.
- AB-130Chloride titrations with potentiometric indication
Potentiometric titration is an accurate method for determining chloride content. For detailed instructions and troubleshooting tips, download our Application Bulletin.
- AB-423Improvement of optical focusing properties in mobile Raman systems for pharmaceutical analysis
This Application Bulletin compares the unique focusing technology of the portable Metrohm Raman system "Mira" with conventional methods. The method described here is called Orbital Raster Scan (ORS). Experiments show the advantages of ORS technology, using determination and quantification of medicines as an example. It improves the reproducibility of the Raman signals from targeted, active, pharmaceutical ingredients (APIs) in effervescent, cold medicines. Shorter analysis times and an improved, consistent assignment of spectra of the known medicine with the help of a spectral library are further advantages of ORS technology.
- AB-077Volumetric water content determination according to Karl Fischer – Tips and tricks for volumetric Karl Fischer titration
This Application Bulletin gives an overview of the volumetric water content determination according to Karl Fischer. Amongst others, it describes the handling of electrodes, samples, and water standards. The described procedures and parameters comply with the ASTM E203.
- AB-358Analysis of residual moisture in a lyophilized pharmaceutical product by near-infrared spectroscopy (NIRS)
This Application Bulletin describes the method of near-infrared spectroscopy in diffuse reflection for the purpose of determining residual moisture in a lyophilized pharmaceutical product. Numerous sample vials containing freeze-dried pharmaceuticals were spiked with varying amounts of water for calibration purposes. The resulting differences in the absorption wavelengths of the OH-oscillation were correlated with the water content determined by Karl Fischer titration using the algorithm of multiple linear regression (MLR).