Search
Market-leading solutions
Product families (69)Product configurations for any application
Product models (712)Tried-and-tested applications
Applications (2250)Electrodes
Electrodes (509)Columns
Columns (155)Accessories
Accessories (2246)Software
Software (266)Manuals & brochures
Documents (2601)News
News (54)Inspiring industry insights
Insights (177)Unmatched support & service
Support & service (79)Other content
Items (86)On-demand webinars
Webinars (72)ProfIC Vario 9 Cation
"ProfIC Vario 9 Cation" – Professional IC Vario system with Metrohm's intelligent preconcentration technique and Inline Matrix Elimination (MiPCT-ME)The Professional IC Vario system with Metrohm's intelligent inline preconcentration technique, Inline Matrix Elimination and conductivity detection enables ultratrace analysis down to the lowest ppt range (ng/L) of cations in complex matrices.Typical areas of application:Ultratrace analysis in samples from nuclear power plants and conventional power plants; Trace and ultratrace analysis in extraction agents and organics; Trace analysis in snow and ice; Schematic representationInstallation instructions
ProfIC Vario 10 Anion
"ProfIC Vario 10 Anion" – Professional IC Vario system with Inline NeutralizationThe Professional IC Vario system with Metrohm Inline Neutralization, sequential suppression and conductivity detection enables the determination of anions in matrices with extreme alkali, acid, or metal contamination.Typical areas of application:Trace analysis in bases and acids; Starter substances from the electroplating industry; Contamination in electroplating baths; Schematic representationInstallation instructions
ProfIC Vario 11 Anion
"ProfIC Vario 11 Anion" – Professional IC Vario system with Inline Neutralization, intelligent preconcentration technique and Inline Matrix EliminationThe Professional IC Vario system with Metrohm Inline Neutralization, Metrohm's intelligent inline preconcentration technique and Inline Matrix Elimination and sequential suppression and conductivity detection enables the analysis of anions in complex matrices from the ultratrace down to the mg/L range.Typical areas of application:Trace analysis in concentrated bases and acids; Ultratrace analysis for nuclear power plants in matrices, such as lithium hydroxide/boric acid; Schematic representationInstallation instructions
ProfIC Vario 12 Anion
"ProfIC Vario 12 Anion" – Professional IC Vario System for online monitoringThe Professional IC Vario system with automatic calibration, Dosino Regeneration,automatic eluent production, sequential suppression and conductivity detection enables the online determination of anions or cations from various sample flows. The system is optimized for uninterrupted use (24/7).Typical areas of application:Continuous analysis of processes; Monitoring of drinking and surface water; Monitoring of cooling water; Trace analysis; Schematic representation
ProfIC Vario 14 AnCat
"ProfIC Vario 14 AnCat" – Professional IC Vario system with Metrohm's intelligent Pick-up Injection Technique (MiPuT)The Professional IC Vario system with Metrohm's intelligent Pick-up Injection Technique (MiPuT), sequential suppression and conductivity detection enables the determination of anions and cations from the smallest of sample volumes.Typical areas of application:For universal application for all types of samples when only small sample amounts are available; Investigation of biochemical processes; Environmental sample extracts; Schematic representation
ProfIC Vario 14 Anion
"ProfIC Vario 14 Anion" – Professional IC Vario system with Metrohm's intelligent Pick-up Injection Technique (MiPuT)The Professional IC Vario system with Metrohm's intelligent Pick-up Injection Technique (MiPuT), sequential suppression and conductivity detection enables the determination of anions or cations from the smallest of sample volumes.Typical areas of application:Universal use for all types of samples when only small sample amounts are available; Investigation of biochemical processes; Environmental sample extracts; Schematic representationInstallation instructions
ProfIC Vario 14 Cation
"ProfIC Vario 14 Cation" – Professional IC Vario system with Metrohm's intelligent Pick-up Injection Technique (MiPuT)The Professional IC Vario system with Metrohm's intelligent Pick-up Injection Technique (MiPuT) and conductivity detection enables the determination of cations or anions (non-suppressed) from the smallest of sample volumes.Typical areas of application:Universal use for all types of samples when only small sample amounts are available; Investigation of biochemical processes; Environmental sample extracts; Schematic representationInstallation instructions
ProfIC Vario 15 AnCat
"ProfIC Vario 15 AnCat" – Professional IC Vario system with Metrohm's intelligent Partial Loop Injection Technique (MiPT)The Professional IC Vario system with Metrohm's intelligent Partial Loop Injection Technique, sequential suppression, and conductivity detection enables fully automated determination of anions and cations. "Partial Loop Injection" enables the injection of various sample volumes.Typical areas of application:Universal use for all types of samples; From trace analysis to waste water analysis; Great differences in concentration in a single sample series; Schematic representationInstallation instructions
ProfIC Vario 15 Anion
"ProfIC Vario 15 Anion" – Professional IC Vario system with Metrohm's intelligent Partial Loop Injection Technique (MiPT)The Professional IC Vario system with Metrohm's intelligent Partial Loop Injection Technique, sequential suppression and conductivity detection enables fully automated determination of anions or cations. "Partial Loop Injection" enables the injection of various sample volumes.Typical areas of application:Universal use for all types of samples; From trace analysis to waste water analysis; Great differences in concentration in a single sample series; Schematic representationInstallation instructions
ProfIC Vario 15 Cation
"ProfIC Vario 15 Cation" – Professional IC Vario system with Metrohm's intelligent Partial Loop Injection Technique (MiPT)The Professional IC Vario system with Metrohm's intelligent Partial Loop Injection Technique and conductivity detection enables fully automatic determination of cations or anions (non-suppressed). "Partial Loop Injection" enables the injection of various sample volumes.Typical areas of application:Universal use for all types of samples; From trace analysis to waste water analysis; Great differences in concentration in a single sample series; Schematic representationInstallation instructions
- AN-H-075AN-H-075Standardization of tetrasodium EDTA solutions
Standardization of ~1mol/L tetrasodium EDTA solutions for thermometric complexometric analysis.
- AN-H-076AN-H-076Determination of iodine value (IV) in fats and oils
Iodine value (IV) is a measure of the total number of double bonds present in fats and oils. It is expressed as the «number of grams of iodine that will react with the double bonds in 100 grams of fats or oils». The determination is conducted by dissolving a weighed sample in a non-polar solvent such as cyclohexane, then adding glacial acetic acid. The double bonds are reacted with an excess of a solution of iodine monochloride in glacial acetic acid («Wijs solution»). Mercuric ions are added to hasten the reaction. After completion of the reaction, the excess iodine monochloride is decomposed to iodine by the addition of aqueous potassium iodide solution, which is then titrated with standard sodium thiosulfate solution.
- AN-H-077AN-H-077Determination of sodium in brines by aluminum titration
Determination of sodium in seawater and similar brines. This procedure is suitable for the analysis of sodium in seawater contaminated with sodium aluminate solutions emanating from alumina refineries, and seawater which has been used for the neutralization of alumina refinery waste («red mud») slurries.
- AN-H-078AN-H-078Determination of total halides in brines
Determination of total halides (Cl- + Br- +I-) in seawater and similar brines. This procedure is suitable for the analysis of total halides in seawater contaminated with sodium aluminate solutions emanating from alumina refineries, and seawater which has been used for the neutralization of alumina refinery waste («red mud») slurries. Given the small concentration of bromine andiodine in seawater, the total halide content approximates the chloride concentration.
- AN-H-079AN-H-079Determination of free acid in heat exchanger cleaning acid
Determination of free acid in sulfuric acid («acid shot») solutions employed in the removal of silicate scale in heat exchangers. This method is suitable for acid shot solutions where the silicic acid content is so high that the solutions have gelled.
- AN-H-080AN-H-080Determination of total sodium in sodium aluminate liquors by aluminum titration
Determination of the total sodium content of sodium aluminate liquors, such as Bayer Process liquor. This method is suitable for the analysis of all sodium aluminate solutions down to at least 1 g/L as Na2CO3. The determination may be automated by adding an 814 USB sample processor to an 859 Titrotherm.
- AN-H-081AN-H-081Determination of phosphoric and nitric acid in nitrophos liquors
Determination of phosphoric and nitric acids in liquors from the Nitrophos fertilizer manufacturing process.
- AN-H-082AN-H-082Determination of surface acidity in Zeolites and other materials with a high specific surface area
This Application Note outlines the determination of total acidic active surface sites in zeolites with thermometric titration.
- AN-H-083AN-H-083Determination of surface basicity in zeolites and other materials with a high specific surface area
This Application Note shows that the parameter of surface basicity of zeolites can be measured by thermometric titration.
- AN-H-084AN-H-084Determination of mixtures of sulfuric, phosphoric, and nitric acids
Determination of mixtures of sulfuric, phosphoric, and nitric acids. The procedure is suitable for automated analysis using an 814 Sample Processor.
6.1458.080
Transfer head for 919 IC Autosampler plus for VA and CVS applications.6.1459.300
Sample beaker, plastic (PP), 120 mL, 250 piecesSample beaker, plastic (polypropylene, PP), 120 mL, suitable for sample racks: 6.2041.470, 6.2041.840, 6.2041.850, 6.2068.010, 6.2068.020, 6.2068.030, and 6.9920.141, 250 pieces
6.1459.307
Sample beaker, plastic (PP), 120 mL, 1 pieceSample beaker, plastic (polypropylene, PP), 120 mL, suitable for sample racks: 6.2041.470, 6.2041.840, 6.2041.850, 6.2068.010, 6.2068.020, 6.2068.030, and 6.9920.141, 1 piece
6.1459.310
Sample beaker, disposable, plastic (PP), 200 mL, 1000 piecesSample beaker, disposable, plastic (polypropylene, PP), 200 mL, suitable for 6.02041.020 OMNIS Software sample rack, 6.2041.370 und 6.2041.830 sample racks, 1000 pieces.
6.1459.320
Screw cap for 61459300 / 250 piecesFor safe closure of 120 mL sample beakers
6.1459.400
Sample beaker, plastic (PE), 75 mL, 144 piecesSample beaker, plastic (polyethylene, PE) 75 mL, suitable for sample racks: 6.2041.340, 6.2041.350, and 6.2041.800, suitable for 6.02041.040 OMNIS Software sample rack, 144 pieces.
6.1462.030
Robotic arm with transfer head for 786 Swing Head, left swingingTransfer robotic arm for liquid handling purposes
6.1462.040
Robotic arm with transfer head for 786 Swing Head, right swingingTransfer robotic arm for liquid handling purposes
6.1462.050
Robotic arm with titration head for 786 Swing Head, left or right swingingTitration head for Swing Head
6.1462.060
Robotic arm with holder for titration head, left swingingTitration head holder to 786 Swing Head