Search
Market-leading solutions
Product families (69)Product configurations for any application
Product models (712)Tried-and-tested applications
Applications (2250)Electrodes
Electrodes (509)Columns
Columns (155)Accessories
Accessories (2246)Software
Software (266)Manuals & brochures
Documents (2601)News
News (54)Inspiring industry insights
Insights (177)Unmatched support & service
Support & service (79)Other content
Items (86)On-demand webinars
Webinars (72)2.930.2360
930 Compact IC Flex Oven/ChS/PP/DegThe 930 Compact IC Flex Oven/ChS/PP/Deg is the intelligent Compact IC instrument with column oven, chemical suppression and a peristaltic pump for suppressor regeneration and built-in degasser. The instrument can be used with any separation and detection methods.Typical areas of application:Anion determinations with chemical suppression and conductivity detection; Organic acids with ion-exclusion chromatography and inverse suppression;
2.930.2400
930 Compact IC Flex Oven/SeSThe 930 Compact IC Flex Oven/SeS is the intelligent Compact IC instrument with column oven and sequential suppression. An 800 Dosino can be used for the regeneration of the suppressor. The instrument can be used with any separation and detection methods.Typical areas of application:Anion or cation determinations with sequential suppression and conductivity detection;
2.930.2460
930 Compact IC Flex Oven/SeS/DegThe 930 Compact IC Flex Oven/SeS/Deg is the intelligent Compact IC instrument with column oven, sequential suppression and built-in degasser. An 800 Dosino can be used for the regeneration of the suppressor. The instrument can be used with any separation and detection methods.Typical areas of application:Anion or cation determinations with sequential suppression and conductivity detection;
2.930.2500
930 Compact IC Flex Oven/SeS/PPThe 930 Compact IC Flex Oven/SeS/PP is the intelligent Compact IC instrument with column oven, sequential suppression and peristaltic pump for suppressor regeneration. The instrument can be used with any separation and detection methods.Typical areas of application:Anion or cation determinations with sequential suppression and conductivity detection;
2.930.2560
930 Compact IC Flex Oven/SeS/PP/DegThe 930 Compact IC Flex Oven/SeS/PP/Deg is the intelligent Compact IC instrument with column oven, sequential suppression, peristaltic pump for suppressor regeneration and built-in degasser. The instrument can be used with any separation and detection methods.Typical areas of application:Anion or cation determinations with sequential suppression and conductivity detection;
2.930.2580
Compact IC Flex Oven/SeS/PP/Deg/MBThe 930 Compact IC Flex Oven/SeS/PP/Deg is the intelligent Compact IC instrument with column oven, sequential suppression, a peristaltic pump for suppressor regeneration and a built-in degasser. The instrument can be used with any separation and detection methods.Typical areas of application:Anion or cation determinations with sequential suppression and conductivity detection; Optimized for microbore (2 mm) applications, ideally suitable for coupling techniques (IC-MS or IC-ICP/MS); Supported with MagIC Net 4.1 and higher
2.930.9030
Metrohm Combustion IC Manual - QuartzThe Metrohm Combustion IC Manual - Quartz package enables the analysis of halogens and sulfur in flammable samples of all types using inline combustion digestion (pyrohydrolysis) with subsequent ion chromatography determination (Combustion IC). It comprises all required components, such as the Combustion Oven (TEI) from Trace Elemental Instruments (2.0136.0600), the quartz combustion tube (6.07311.100), the 920 Absorber Module, the 930 Compact IC Flex Oven/SeS/PP/Deg, and the MagIC Net software. If necessary, the Metrohm Combustion IC package can be supplemented with one of the following Autosamplers: Solid Autosampler CIC (TEI), Liquid Autosampler CIC (TEI) or GLS Sampler CIC (TEI).
2.930.9040
Metrohm Combustion IC Manual - CeramicThe Metrohm Combustion IC Manual - Ceramic package enables the analysis of halogens and sulfur in flammable samples of all types using inline combustion digestion (pyrohydrolysis) with subsequent ion chromatography determination (Combustion IC). It comprises all required components, such as the Combustion Oven (TEI) from Trace Elemental Instruments (2.0136.0600), the ceramic combustion tube (6.07311.110), the 920 Absorber Module, the 930 Compact IC Flex Oven/SeS/PP/Deg, and the MagIC Net software. If necessary, the Metrohm Combustion IC package can be supplemented with one of the following Autosamplers: Solid Autosampler CIC (TEI), Liquid Autosampler CIC (TEI) or GLS Sampler CIC (TEI).
2.940.1100
940 Professional IC Vario ONEThe 940 Professional IC Vario ONE is the intelligent IC instrument for applications without suppression. The instrument can be used with any separation and detection methods.Typical areas of application:Anion and cation determinations without suppression; Analyses with UV/VIS detection with or without post-column derivatization; Applications with amperometric detection (e.g., sugar analysis); Trace analysis for cations with MiPCT;
2.940.1110
940 Professional IC Vario ONE/Prep 1The 940 Professional IC Vario ONE/Prep 1 is the intelligent IC instrument without suppression in combination with MetrohmInline Sample Preparation, e.g., Inline Ultrafiltration or Inline Dialysis. The instrument can be used with any separation and detection methods.Typical areas of application:Anion and cation determinations without suppression after Inline Ultrafiltration or Inline Dialysis; UV/VIS applications after Inline Ultrafiltration or Inline Dialysis; Applications with amperometric detection after Inline Ultrafiltration or Inline Dialysis;
- AN-CIC-003AN-CIC-003Chlorine, bromine and sulfur in low-density polyethylene (ERM®-EC680k) using Combustion IC
The determination of halogens and sulfur in waste products is important. The inline combination of the Mitsubishi Combustion Module with the Metrohm IC is a suitable method for this type of samples. The recovery rates are analyzed with a certified reference material, e.g., a low-density polyethylene (LDPE).Keyword: pyrohydrolysis
- AN-CIC-004AN-CIC-004Total and leachable concentration of halogens and sulfur in latex gloves using Combustion Ion Chromatography and a leaching test
Latex gloves are used in clean room environments in order to prevent contaminations. The use of gloves that release corrosive halogenides or sulfate is forbidden in nuclear power plants. The total content of halogen and sulfur is determined by means of Combustion Ion Chromatography. An eluate test is carried out to check the elutable percentage of halogens and sulfate from gloves. Sample preparation is comprised of preconcentration and matrix elimination (MiPCT-ME), as described in AN-S-304.Keyword: pyrohydrolysis
- AN-CIC-005AN-CIC-005Iodine in a pharmaceutical product using Combustion Ion Chromatography with Inline Matrix Elimination
The iodine content in numerous iodized X-ray contrast media (ICM) is around 50% and is determined with great accuracy using Combustion Ion Chromatography. Large quantities of H2O2 (1,000 mg/L) are required for complete absorption of the iodine. Similarly, the concentration of the internal standard should be 50 mg/L. The water content of the X-ray contrast media is determined by means of Metrohm's Karl Fischer oven method and incorporated in the final calculation.Keyword: pyrohydrolysis
- AN-CIC-006AN-CIC-006Recovery rates of chloride, bromide and sulfate in certified reference materials using Metrohm Combustion Ion Chromatography
Combustion Ion Chromatography combines pro-hydrolytic sample combustion and the absorption of emerging combustion gases in an oxidizing, aqueous solution that is then channeled to an ion chromatograph for the analysis of halogenides and sulfur (as sulfate). The combustion and analysis of the certified reference materials (ZRM) makes clear the reliability of Metrohm Combustion Ion Chromatography.Keyword: pyrohydrolysis
- AN-CIC-007AN-CIC-007Analysis of a standard mixed in liquid using Metrohm Combustion IC
This application describes the determination of fluoride, chloride, bromide and sulfur (as sulfate) in an ethanol standard solution with halo organic (4-halogen benzoic acids; F, Cl and Br) and sulfur organic compounds (3-(Cyclohexylamino)-1-propanesulfonic acid) by means of Metrohm Combustion Ion Chromatography with flame sensor and Inline Matrix Elimination.Keyword: pyrohydrolysis
- AN-CIC-008AN-CIC-008Fluorine in polyisobutene using Metrohm Combustion IC
Polyisobutene (PIB) is an important raw material for a large range of products. Quality control requires the determination of the fluorine content. This task is easily done by Metrohm Combustion IC applying flame sensor technology and Inline Matrix Elimination.Keyword: pyrohydrolysis
- AN-CIC-009AN-CIC-009Chloride and sulfur in cyclohexane using Metrohm Combustion IC
Cyclohexane is an important organic solvent. Recycled cyclohexane must be tested for trace substances, e.g., chloride and sulfate. Metrohm Combustion Ion Chromatography with flame sensor and Inline Matrix Elimination is the method of choice.Keyword: pyrohydrolysis
- AN-CIC-010AN-CIC-010Halogens in a polymer sample applying Metrohm Combustion IC according to IEC 60754
The Restriction of Hazardous Substances Directive (RoHS) requires to reduce the halogen content in several organic materials used in electrical and electronic equipment. In this context, there is a huge interest for using halogen-free polymers. To check for halogens in polymers according to standard IEC 60754, Metrohm Combustion IC applying flame sensor technology and Inline Matrix Elimination is an indispensable method. The examined polymeric material contains halogens at a level of up to 1%.
- AN-CIC-011AN-CIC-011Analysis of an ion exchanger using Metrohm Combustion IC
The manufacture of ultrapure water for the pharmaceuticals industry or the semiconductor industry requires high-quality ion exchangers. Metrohm Combustion Ion Chromatography is an indispensable tool in this connection for testing the purity of anion exchange material. The output sample was wet and had to be dried at 105 °C in a special oven with waste air evacuation.Keyword: pyrohydrolysis
- AN-CIC-012AN-CIC-012Halogens and sulfur in clay using Metrohm Combustion IC
Clay is used for the manufacture of roofing tiles. Quality controls during this process require the determination of halogen and sulfur content. This is ideally accomplished using Metrohm Combustion IC. With this method, the sulfur is determined as sulfate and the halogens as halogenides. Because clay often contains high contents of alkali and earth alkali metal ions that attack the pyrolysis tube, tungsten oxide is added prior to combustion.Keyword: pyrohydrolysis
PT.25
Platinum micro electrode 25 µmPlatinum micro electrode with a disk diameter of 25 µm.
PT.300
Platinum micro electrode 300 µmPlatinum micro electrode with a disk diameter of 300 µm.
PT.50
Platinum micro electrode 50 µmPlatinum micro electrode with a disk diameter of 50 µm.
PT.500
Platinum micro electrode 500 µmPlatinum micro electrode with a disk diameter of 500 µm.
PT.SHEET
Platinum sheet electrodeThis electrode consists of a thin sheet of platinum embedded into a glass shaft. This electrode can be used as a counter electrode for most electrochemical measurements. The surface area is approximatively 1 cm².
PW-4XIDEAU20
Multi-interdigitated Gold Electrode / 20 microns lines and gaps / Plastic White SubstrateThese multi-electrodes are formed by four interdigitated gold electrodes in one piece. The interdigitated configuration improves the detection limits and sensitivity. The dimensions of the bands/gaps are 20 μm.
PW-4XIDEAU30
Multi-interdigitated Gold Electrode / 30 microns lines and gaps / Plastic White SubstrateThese multi-electrodes are formed by four interdigitated gold electrodes in one piece. The interdigitated configuration improves the detection limits and sensitivity. The dimensions of the bands/gaps are 30 μm.
PW-4XIDEAU40
Multi-interdigitated Gold Electrode / 40 microns lines and gaps / Plastic White SubstrateThese multi-electrodes are formed by four interdigitated gold electrodes in one piece. The interdigitated configuration improves the detection limits and sensitivity. The dimensions of the bands/gaps are 40 μm.
PW-4XIDEAU50
Interdigitated Gold Electrode / 50 microns lines and gaps / Plastic White SubstrateThese multi-electrodes are formed by four interdigitated gold electrodes in one piece. The interdigitated configuration improves the detection limits and sensitivity. The dimensions of the bands/gaps are 50 μm.
PW-4XIDEAU60
Multi-interdigitated Gold Electrode / 60 microns lines and gaps / plastic white substrateThese multi-electrodes are formed by four interdigitated gold electrodes in one piece. The interdigitated configuration improves the detection limits and sensitivity. The dimensions of the bands/gaps are 60 μm.
6.07401.060
Holder OMNIS NIR, vial, 4 mmVial Holder for the OMNIS NIR Analyzer for 4 mm disposable vials (6.7402.250).
6.07401.070
Holder OMNIS NIR, vial, 8 mmVial Holder for the OMNIS NIR Analyzer for 8 mm disposable vials (6.7402.240).
6.07401.080
Holder OMNIS NIR, vial, 10 mmVial Holder for the OMNIS NIR Analyzer for 10 mm disposable vials (6.7402.100).
6.07401.100
Holder OMNIS NIR, flow-through cellsCuvette holder for the OMNIS NIR Analyzer for flow-through cells(6.7401.300; 6.7401.310; 6.7401.320; 6.7401.330; 6.7401.340).
6.07401.110
Flow-through connector set, 1/8"Connection set for flow-through cells with an OMNIS Sample Robot.Contains flangeless sleeve 1/8", 10 pcs., Flangeless fitting with nut, 1/8", 10 pcs. and FEP tubings 1/8" x 1.59 mm, 4 pcs.
6.07401.320
Flow-through cell, 2 mmFlow quartz cuvettes with an optical path length of 2.0 mm suitable for near-infrared spectroscopy (NIRS) analyses.Compatible with:Holder OMNIS NIR, flow-through cell (6.070401.100);
6.07401.330
Flow-through cell, 2.5 and 5 mmFlow quartz cuvettes with quartz glass window and two optical path lengths (2.5 mm or 5.0 mm) suitable for near-infrared spectroscopy (NIRS) analyses.Compatible with:Holder OMNIS NIR, flow-through cell (6.070401.100)
6.07401.340
Flow-through cell, 5 and 10 mmFlow quartz cuvettes with quartz glass window and two optical path lengths (5.0 mm or 10.0 mm) suitable for near-infrared spectroscopy (NIRS) analyses.Compatible with:Holder OMNIS NIR, flow-through cell (6.070401.100);
6.07402.100
Large holder OMNIS NIR, 100 mmLarge holder for large sample vessel OMNIS NIR, 100 mm (6.07402.110).Permits unambiguous positioning of the sample vessel and the rotation of the sample vessel.
6.07402.110
Large cup OMNIS NIR, 100 mmLarge sample vessel for the spectra acquisition of powders and granulates in reflection at various sample positions.Compatible with:Large holder OMNIS NIR, 100 mm (6.07402.100);