Search
Market-leading solutions
Product families (69)Product configurations for any application
Product models (712)Tried-and-tested applications
Applications (2250)Electrodes
Electrodes (509)Columns
Columns (155)Accessories
Accessories (2246)Software
Software (266)Manuals & brochures
Documents (2601)News
News (54)Inspiring industry insights
Insights (177)Unmatched support & service
Support & service (79)Other content
Items (86)On-demand webinars
Webinars (72)2.928.0310
NIRS XDS Process Analyzer – DirectLight/NonContact-Single pointBased on NIR XDS technology, the NIRS XDS Process Analyzer – DirectLight/NonContact is numbered among the next generation of non-contact process analyzers for real-time analysis above a conveyor belt, web or sheet. Non-destructive, accurate measurements are performed of practically any moving solid product.
2.928.1110
NIRS Analyzer PRO – ContactReflectionThe NIRS Analyzer Pro is a single point process analysis system based on high resolution diode array technology. It provides non-destructive analysis of granules, powders through a glass window directly in the process line without bypass – a true in-line system.
2.928.1120
NIRS Analyzer PRO – FiberSystemThe NIRS Analyzer Pro is a single point process analysis system based on high resolution diode array technology. It provides non-destructive analysis of liquids, granules, powders, slurries or opalescent substances by using fiber optics microbundles and contact probes for reflectance, transflectance and transmission measurements.
2.928.1130
NIRS Analyzer PRO – DirectLight/NonContactThe NIRS Analyzer Pro is a single point process analysis system based on high resolution diode array technology. It provides non-destructive analysis of solids like granules and powders. This system is typically mounted above a conveyor belt in order to analyze products passing by.
2.930.1100
930 Compact IC FlexThe 930 Compact IC Flex is the intelligent Compact IC instrument without suppression. The instrument can be used with any separation and detection methods.Typical areas of application:Anion or cation determinations without suppression with conductivity detection; Simple applications with UV/VIS or amperometric detection;
2.930.1160
930 Compact IC Flex DegThe 930 Compact IC Flex Deg is the intelligent Compact IC instrument without suppression with built-in degasser. The instrument can be used with any separation and detection methods.Typical areas of application:Anion or cation determinations without suppression with conductivity detection; Simple applications with UV/VIS or amperometric detection;
2.930.1200
930 Compact IC Flex ChSThe 930 Compact IC Flex ChS is the intelligent Compact IC instrument with chemical suppression. An 800 Dosino can be used for the regeneration of the suppressor. The instrument can be used with any separation and detection methods.Typical areas of application:Anion determinations with chemical suppression and conductivity detection; Organic acids with ion-exclusion chromatography and inverse suppression;
2.930.1260
930 Compact IC Flex ChS/DegThe 930 Compact IC Flex ChS/Deg is the intelligent Compact IC instrument with chemical suppression and built-in degasser. An 800 Dosino is used for the regeneration of the suppressor. The instrument can be used with any separation and detection methods.Typical areas of application:Anion determinations with chemical suppression and conductivity detection; Organic acids with ion-exclusion chromatography and inverse suppression;
2.930.1300
930 Compact IC Flex ChS/PPThe 930 Compact IC Flex ChS/PP is the intelligent Compact IC instrument with chemical suppression and a peristaltic pump for regeneration. The instrument can be used with any separation and detection methods.Typical areas of application:Anion determinations with chemical suppression and conductivity detection; Organic acids with ion-exclusion chromatography and inverse suppression;
2.930.1360
930 Compact IC Flex ChS/PP/DegThe 930 Compact IC Flex ChS/PP/Deg is the intelligent Compact IC instrument with chemical suppression and a peristaltic pump for regeneration and a built-in degasser. The instrument can be used with any separation and detection methods.Typical areas of application:Anion determinations with chemical suppression and conductivity detection; Organic acids with ion-exclusion chromatography and inverse suppression;
- AN-C-181AN-C-181Potassium in potassium bitartrate as per USP
Within the scope of the USP monograph modernization, potassium is determined in potassium bitartrate applying cation chromatography with direct conductivity detection. The USP41 monograph for “Potassium bitartrate” does not yet mention an assay for potassium. The separation is performed on a Metrosep C 6 - 150/4.0 column (L76). The assay of potassium is performed with two commercially available products according to USP definitions. All acceptance criteria are fulfilled.
- AN-C-182AN-C-182Potassium in potassium sodium tartrate as per USP
Within the scope of the USP monograph modernization, potassium is determined in potassium sodium tartrate applying cation chromatography with direct conductivity detection. The USP41 monograph for “Potassium sodium tartrate” does not yet mention an assay for potassium. The separation is performed on a Metrosep C 6 - 150/4.0 column (L76). The assay of potassium is performed with two commercially available products according to USP definitions. All acceptance criteria are fulfilled.
- AN-C-183Potassium in potassium bicarbonate effervescent tablets for oral solution
Within the scope of the USP monograph modernization, potassium is determined in potassium bicarbonate effervescent tablets for oral suspension applying cation chromatography with direct conductivity detection. The separation is performed on a Metrosep C 6 - 150/4.0 column (L76). All acceptance criteria are fulfilled.
- AN-C-184Potassium and sodium bicarbonates and citric acid effervescent tablets for oral solution
As an alternative to flame photometry, ion chromatography with non-suppressed conductivity detection has been approved by the USP as a validated method to quantify potassium and sodium content in potassium and sodium bicarbonates and citric acid effervescent tablets for oral solution. The present IC method has been validated according to USP General Chapter <621>.
- AN-C-185Potassium in potassium bicarbonate and potassium chloride effervescent tablets for oral solution
As an alternative to flame photometry, ion chromatography with non-suppressed conductivity detection has been approved by the USP as a validated method to quantify potassium content in potassium bicarbonate and potassium chloride effervescent tablets for oral solution. The Metrosep C 6 - 150/4.0 column (L76) provides the required separation of potassium and magnesium. The present IC method has been validated according to USP General Chapter <621>.
- AN-C-186AN-C-186Sodium in potassium sodium tartrate as per USP
Within the scope of the USP monograph modernization, sodium is determined in potassium sodium tartrate applying cation chromatography with direct conductivity detection. The USP41 monograph for «Potassium sodium tartrate» does not yet mention an assay for sodium. The separation is performed on a Metrosep C 6 - 150/4.0 column (L76). The assay of potassium is performed with two commercially available products according to USP definitions. All acceptance criteria are fulfilled. See AN-C-182 for the respective determination of potassium. Apllying this method allows to determine sodium and potassium simultaneously according to USP.
- AN-C-187AN-C-187UOP 939-96: Basic Nitrogen in LPG by Ion Chromatography
Natural liquefied petroleum gas (LPG) is a mixture of hydrocarbon gases (e.g. propane and butane), but it also contains acidic contaminants (e.g. carbon dioxide or hydrogen sulfide). These gases need to be scrubbed from the petroleum gas as they are highly corrosive. This purification step, referred to as «sweetening», is often performed by using alkaline amine solutions. Thereby the amine solution absorbs the acidic gases, while the raw LPG is neutralized. To guarantee that amine residues in the sweetened gas do not influence the gas quality, the amines in the final LPG are determined by scrubbing the gas with acetic acid as described in UOP 936-96. The recent method enables the quantification of the amines dimethylamine (DMA), diethylamine (DEA), dipropylamine (DPA), and dibutylamine (DBA) by separation from standard cations.
- AN-C-188AN-C-188Ammonium impurities in potassium bitartrate
Potassium bitartrate for pharmaceutical use must comply with USP requirements. The actual monograph (USP 42) uses a colorimetric method for the determination of ammonium impurities. Ion chromatography allows the measurement in a single determination under the same conditions used for the potassium assay (see AN-C-181). In the course of the USP monograph modernization, this ion chromatographic approach makes this type of analysis even easier.
- AN-C-189AN-C-189Cations in lithium ore
The exploration and processing of lithium ores is gaining importance with the growing demand for lithium hydroxide. Lithium hydroxide is a key component in the manufacturing of rechargeable batteries for use in various applications including electric vehicles, home storage systems, power tools and consumer electronics. To ensure the efficiency for advanced processing of high purity lithium hydroxide, a fast and reliable quantitative detection technique is required. This application has been developed to monitor the lithium, sodium, and calcium content in the lithium processing samples and mineral concentrates.
- AN-C-190AN-C-190Analysis of amine emulsifiers besides standard cations
Isopropylamine and dicyclohexylamine are used as emulsifiers and need to be determined in emulsions along with standard cations. However, emulsions must not be injected directly into the ion chromatograph as the organic components may damage the ion exchanger stationary phase in the separation column. Inline Dialysis as sample preparation is the perfect tool for such samples. The ions of interest are separated from the organic phase by diffusion through the hydrophilic membrane, thus protecting the column. Full automation makes the analyses even easier and more efficient for the user.
G-MEAB555
Platinum Band MicroElectrode arraysPlatinum Band MicroElectrodes Arrays are composed of an auxiliary, reference and working electrode all made in platinum. The working electrode is a metallic surface made of platinum covered by a SU-8 resin microperforated, defining an array of bands of 10 µm width. These microarray electrodes exhibit enhanced diffusion, sensitivity and detection limits
IDEAU200-HPT-WB
Interdigitated gold electrode with heaterInterdigitated elecrode recommended for the development of gas sensors by depositing a sensing layer (semiconductor metal oxide) in the interdigitated area. Bondable contacts allow wire bonding process. On the other side, a Platinum heater can be used to control the operating temperature in the sensing layer, due to the high thermal conductivity of the ceramic substrate used in this device.
IR.75
Iridium micro electrode 75 µmIridium micro electrode with a disk diameter of 75 µm.
LACT10
Lactate sensorSuitable for the determination of L(+)-Lactate determination in liquid samples.
MH-110
Screen-printed carbon electrodes with microholesThese disposable screen-printed carbon electrodes consist of a working electrode with 19 spherical microholes distributed hexagonally
PD.100
Palladium micro electrode 100 µmPalladium micro electrode with a disk diameter of 100 µm.
PD.200
Palladium micro electrode 200 μmPalladium disk micro-electrode tip of 200 μm diameter.
PD.25
Palladium micro electrode 25 µmPalladium micro electrode with a disk diameter of 25 µm.
PD.300
Palladium micro electrode 300 µmPalladium micro electrode with a disk diameter of 300 µm.
PD.500
Palladium micro electrode 500 µmPalladium micro electrode with a disk diameter of 500 µm.
6.07311.300
Septum cap Liquid Introduction ModuleLid for fastening the 6.07311.290 septum in place in the Liquid Introduction Module.
6.07311.310
Oxygen and UPW supply tubing (TEI)Tubing for oxygen and ultrapure water supply at the inlet to the combustion tube (TEI).
6.07311.350
Replacement filter Combustion Oven (TEI)Spare filter for the fan in the Combustion Oven (TEI).
6.07312.010
Solid sample tray no. 1Solid sample tray no. 1 for the Solid Autosampler CIC (2.0136.0620) for 20 positions.
6.07312.020
Solid sample tray no. 2Solid sample tray no. 2 for the Solid Autosampler CIC (2.0136.0620) for 20 positions.
6.07312.030
Solid sample tray no. 3Solid sample tray no. 3 for the Solid Autosampler CIC (2.0136.0620) for 20 positions.
6.07313.020
Screw incl. ferrule for Liquid Autosampler CIC (TEI)Screw including collapsible ferrule for 1/16" tubing to connect the transfer line to the needle on the Liquid Autosampler CIC (TEI).
6.07313.040
Wash/waste container set for Liquid Autosampler CIC (TEI)Wash/waste container set for the Liquid Autosampler CIC (TEI).
6.07313.050
Prime Vial Set for Liquid Autosampler CIC (TEI)Set of Prime Vials for the preparation of the Liquid Autosampler CIC (TEI).
6.07313.100
Syringe 100 µl manual injection (TEI)Dosing syringe for manual injection of liquid samples using one of the three Introduction Modules (6.07311.010, 6.07311.020, or 6.07311.030).
- 8.108.80148.108.8014Manual for 21360200 KF Evaporator
English
- 8.109.14988.109.1498Instructions for Use Spectrosense, German/English/French/Spanish
English
Other languages
- 8.110.13868.110.1386Instructions for Use for 6.5613.000 ECO Titration Equipment, german/french/english
English
Other languages
- 8.110.19988.110.1998Leaflet for 6.2129.010 Differential amplifier, german/french/english/spanish
English
Other languages
- 8.110.80038.110.8003Manual for 6.5331.0X0 Equipment Sets with Flow Cell for Bioscan
English
Other languages
- 8.110.80098.110.800981108371: Manual for 6.5331.1X0 Accessory Set with Variocell for Bioscan
English
Other languages
- 8.110.80158.110.8015Manual to IC Equipment Wall-Jet-Cell
English
Other languages
- 8.110.80208.110.8020Manual for IC equipment Thin-Layer cell
English
Other languages
- 8.110.80228.110.8022Manual to Power Box (for 899 Coulometer)
English
Other languages
- 8.110.80288.110.8028Manual for IC equipment: Inline Dialysis
English
Other languages