823 Membrane Pump UnitMembrane pump for direct connection to Sample Processors.
2.823.0020
823 Membrane Pump Unit «aspirate»Membrane pump for direct connection to Sample Processors. The «Aspiration» version contains numerous accessories for aspirating off solutions.
2.823.0030
823 Membrane Pump Unit «rinse»Membrane pump for direct connection to Sample Processors. The «Rinsing» version contains numerous rinsing accessories.
2.824.0020
824 Easy Sample ChangerThe economic sample changer for routine use.Easy Sample Changer Micro: sample changer for titrations with smaller sample volumes. Up to 24 samples with a maximum volume of 75 mL can be processed in a single run. With the KFT equipment the Easy Sample Changer can be converted to a Karl Fischer sample changer.
2.826.0010
826 pH mobilePortable pH meter with IrDa interface, including carrying strap and batteries.
2.826.0020
826 pH mobile with PrimatrodePortable pH meter with IrDa interface, including carrying strap, batteries and 6.0228.020 Primatrode with NTC (IP67).
2.826.0110
826 pH mobile with carrying casePortable pH meter with IrDa interface. With carrying case, ample accessories for calibration, including 6.0228.020 Primatrode.
2.827.0014
pH Lab Irda 230 V EU2.827.0015
pH Lab Irda 120 V US2.827.0017
pH Lab Irda 240 V AUS
- AB-315AB-315Determination of free fatty acids (FFA) in edible oils with 859 Titrotherm
In titration, the titrant reacts with the analyte either exothermically (gives off heat) or endothermically (absorbs heat). The Thermoprobe measures the temperature change during titration. When all of the analyte has reacted with the titrant, the temperature of the solution will change, and the endpoint of the titration is indicated by an inflection in the temperature curve. Catalytically enhanced titrations using paraformaldehyde as catalyst are based on the endothermic hydrolysis of the paraformaldehyde in the presence of excess hydroxide ions. Edible oils are dissolved in a mixture of toluene and 2-propanol (1:1) and titrated with standardized TBAH (0.01 mol/L) in 2-propanol to a catalytically enhanced endpoint.
- AB-316AB-316Determination of phosphoric acid in liquid fertilizer with 859 Titrotherm
The phosphoric acid content can be easily titrated with a standardized solution of 2 mol/L NaOH. The interfering calcium content in phosphoric fertilizer can be eliminated by adding a saturated oxalate solution.
- AB-317AB-317Determination of iron in the µg/L-range by polarography
This Application Bulletin describes two methods for the determination of iron at the Multi Mode Electrode.Method 1, the polarographic determination at the DME, is recommended for concentrations of β(Fe) > 200 μg/L. For this method the linear range is up to β(Fe) = 800 μg/L.For concentrations < 200 μg/LMethod 2, the voltammetric determination at the HMDE, is to be preferred. The detection limit for this method is β(Fe) = 2 μg/L, the limit of quantification is β(Fe) = 6 μg/L. The sensitivity of the method cannot be increased by deposition.Iron(II) and iron(III) have the same sensitivity for both methods.These methods have been elaborated for the determination of iron in water samples. For water samples with high calcium and magnesium concentrations such as, for example, seawater, a slightly modified electrolyte is used in order to prevent precipitation of the corresponding metal hydroxides. The methods can also be used for samples with organic loading (wastewater, beverages, biological fluids, pharmaceutical or crude oil products) after appropriate digestion.
- AB-322AB-322Fully automated potentiometric determination of the hydroxyl number (HN) according to ASTM E1899 and DIN EN ISO 4629-2
The presented titration system can be used for the fully automated determination of the hydroxyl number (HN) according to ASTM E1899 and EN ISO 4629-2. The method allows, the determination of polyols and oxooils without boiling under reflux or other sample preparation and is therefore a big benefit for laboratories that have to cope with a high sample throughput.The standards EN 15168 and DIN 53240-3 relay on the same analysis method as in ASTM E1899.
- AB-340AB-340Bromine index (BI) by coulometric titration
This bulletin describes a procedure to determine the bromine index (BI) using coulometric titration. The bromine index is the fraction of reactive unsaturated compounds (mostly C=C double bonds) in hydrocarbons encountered in the petrochemical industry. The double bonds are split with the attachment addition of bromine.
- AB-342AB-342Automated calcium and magnesium determination in milk using 859 Titrotherm and 814 USB Sample Processor
This bulletin deals with the automated determination of calcium and magnesium in commercially available finished milk products using a 859 Titrotherm and a 814 USB Sample Processor. Calcium and magnesium in milk can be rapidly and easily titrated thermometrically using a standard solution of Na4EDTA as titrant.Thermometric titrations are conducted under conditions of constant titrant addition rate. The molarity of the titrant is computed automatically in tiamo (software) using the SLO command. Results are reported as mg Ca and Mg/100 mL.
- AB-343AB-343Automated sodium determination in milk using 859 Titrotherm and 814 USB Sample Processor
This bulletin discusses automated determination of sodium in milk products available to the public using a 859 Titrotherm and a 814 USB Sample Processor. The sodium content of milk can be rapidly and easily titrated thermometrically with a standard solution of Al3+ as titrant. Thermometric titrations are conducted under conditions of constant titrant addition rate. The molarity of the titrant is computed automatically in tiamoTM (software) with the SLO command. Results are reported as mg Na/100 mL. In addition to this application bulletin, you can find more information on thermometric sodium determination in foods in our application video available on YouTube:https://youtu.be/lnCp9jBxoEs
- AB-344AB-344Automated analysis of etch acid mixtures using the 859 Titrotherm and the 814 USB Sample Processor
This bulletin deals with the automated determination of mixtures of HNO3, HF and H2SiF6 in the range of approximately 200-600 g/L HNO3, 50-160 g/L HF, and 0-185 g/L H2SiF6 using thermometric titration.Etch acid mixtures containing HNO3, HF and H2SiF6 from the etching of silicon substrates can be analyzed in a sequence of two determinations using the 859 Titrotherm. The first determination involves a direct titration with standard c(NaOH) = 2 mol/L, followed by a back titration with c(HCl) = 2 mol/L. This determination yields the H2SiF6 content plus a value for the combined (HNO3+HF) contents. The second determination consists of a titration with c(Al3+) = 0.5 mol/L to determine the HF content. For freshly made up mixtures of HNO3 and HF containing no H2SiF6, a linked two-titration sequence is employed. Results from the two determinations are used by tiamoTM to yield individual results for HNO3, HF and H2SiF6.
- AB-348AB-348Installation Instruction for a Low-Pressure Gradient System
This document describes the recommended equipment and the installation of a Low-Pressure Gradient system as well as the method import and handling in MagIC Net.
- AB-349AB-349Installation Instruction for a Dose-in Gradient System
This document describes the recommended equipment and the installation of a Dose-in gradient system as well as the method import and handling in MagIC Net.
BWT-840001251
TacticID Illicit and General Chemicals LibraryTacticID N Plus library of illicit materials includes drugs, TICs, TIMs, precursors, and general chemicals.
BWT-840001252
TacticID Mobile Illicit and General Chemicals LibraryTacticID Mobile library of illicit materials includes drugs, TICs, TIMs, precursors, and general chemicals.
BWT-840001253
TacticID-1064/ST Illicit and General Chemicals LibraryTacticID-1064/ST library of illicit materials includes drugs, TICs, TIMs, precursors, and general chemicals.
BWT-840001254
BWID Illicit and General Chemicals LibraryBWID library of illicit materials includes drugs, TICs, TIMs, precursors, and general chemicals.
NOVA
Advanced software for electrochemical researchNOVA is the package designed to control all the Autolab instruments with USB interface.Designed by electrochemists for electrochemists and integrating over two decades of user experience and the latest .NET software technology, NOVA brings more power and more flexibility to your Autolab potentiostat/galvanostat.NOVA offers the following unique features:Powerful and flexible procedure editor; Clear overview of relevant real-time data; Powerful data analysis and plotting tools; Integrated control for external devices like Metrohm Liquid Handling devices; Download the latest version of NOVA
SDK
Software development kitThe Autolab Software Development Kit (Autolab SDK) is designed to control the Autolab instrument from different external applications such as LabVIEW, Visual Basic for Applications (VBA), scripting etc. With the Autolab SDK the external application can be used to measure complete procedures or control individual Autolab modules.In order to use the Autolab SDK from other applications, these applications must have the possibility to use .NET assemblies or in the case of 'older' applications to use COM assemblies. How to integrate these assemblies is explained in the manual of the application.The Autolab SDK is compatible with Autolab NOVA however it does not require NOVA to be installed.
6.0430.100S
Ag Titrode with sulfide coatingCombined silver ring electrode with a pH glass membrane as reference electrode.The silver ring is coated with sulfide (Ag2S) for a higher sensitivity and a better limit of detection. This maintenance-free electrode is well suited for precipitation titrations when the pH value remains constant (titrant silver nitrate) of, e.g.: chloride, bromide, iodide; sulfides; hydrogen sulfide; mercaptans; cyanides ; This electrode is stored in deion. water.
6.0431.100
Pt TitrodeCombined platinum ring electrode with a pH glass membrane as reference electrode.This maintenance free electrode is well suited for redox titrations when the pH value remains constant, e.g.: iodometry; chromatometry; cerimetry; permanganometry; This electrode is stored in deion. water.
6.0433.110
Micro Ag TitrodeCombined silver ring electrode with a pH glass membrane as reference electrode, narrowed to a diameter of 6.4 mm.This maintenance-free electrode is well suited for precipitation titrations when the pH value remains constant (titrant silver nitrate) of, e.g.: chloride, bromide, iodide; sulfides; hydrogen sulfide; mercaptans; cyanides ; This electrode is stored in deion. water.Depending on the application, we recommend using an Ag Titrode with an Ag2S coating, which can be ordered accordingly.
6.0434.110
Micro Pt Titrode (installation length 17.8 cm)Combined platinum ring electrode with a pH glass membrane as reference electrode, installation length = 17.8 cm, narrowed to a diameter of 6.4 mm.This maintenance-free electrode is well suited for redox titrations when the pH value remains constant of, e.g.: iodometry; chromatometry; cerimetry; permanganometry; This electrode is stored in deion. water.
6.0435.110
Micro Au Titrode (installation length 17.8 cm)Combined gold ring electrode with a pH glass membrane as reference electrode, installation length = 17.8 cm, narrowed to a diameter of 6.4 mm.This maintenance-free electrode is well suited for redox titrations when the pH value remains constant, e.g.: determination of the chemical oxygen demand (COD, ferrometry); determination of penicillin and ampicillin; for titrations using Hg(NO3)2; for titrations in presence of chromium or iron; This electrode is stored in deion. water.
6.0450.100
Comb. Ag ring electrodeCombined silver ring electrode with a ceramic pin diaphragm.This electrode is well suited for precipitation titrations when the pH value varies (titrant silver nitrate) of, e.g.: chloride, bromide, iodide; sulfides; hydrogen sulfide; mercaptans; cyanides ; c(KNO3) = 1 mol/L is used as reference electrolyte and storage solution.Depending on the application, we recommend using an Ag Titrode with a coating (AgBr or Ag2S coating), which can be ordered accordingly.
6.0450.100S
Comb. Ag ring electrode with Ag2S coatingCombined silver ring electrode with a ceramic pin diaphragm.The silver ring is coated with sulfide (Ag2S) for a higher sensitivity and a better limit of detection.This electrode is well suited for precipitation titrations when the pH value varies (titrant silver nitrate) of, e.g.: chloride, bromide, iodidesulfideshydrogen sulfidemercaptanscyanides c(KNO3) = 1 mol/L is used as reference electrolyte and storage solution.
6.0450.300
Comb. iAg ring electrodeIntelligent, combined silver ring electrode with integrated memory chip for storing of sensor data.This electrode is suitable for precipitation titrations when the pH value varies (titrant silver nitrate) of, e.g.: Chloride, Bromide, Iodide; Sulfides; Hydrogen sulfide; Mercaptans; Cyanides; c(KNO3) = 1 mol/L is used as reference electrolyte and for storage.iTrodes can be used on Titrando, Ti-Touch or 913/914 meters.
6.0451.100
Combined Pt ring electrodeCombined platinum ring electrode with a ceramic pin diaphragm.This electrode is well suited for redox titrations when the pH value varies, e.g.: oxygen content according to Winkler; determination of hydrogen peroxide with KMnO4; diazotization titrations; c(KCl) = 3 mol/L is used as reference electrolyte and storage solution.
6.0451.300
Combined iPt ring electrodeIntelligent, combined platinum ring electrode with integrated memory chip for storing sensor data.This electrode is suitable for redox titrations where the pH value varies, e.g.: Oxygen content according to Winkler; Determination of hydrogen peroxide with KMnO4; Diazotization titrations; c(KCl) = 3 mol/L is used as reference electrolyte and for storage.iTrodes can be used on Titrando, Ti-Touch or 913/914 meters.
6.02007.020
Lid trays for OMNIS Sample Robot M/LLid trays for assembly on OMNIS pump modules or 6.02007.000 blind plate attachments in the OMNIS Sample Robot M or L system.
6.02008.010
Polytron holderFor fastening the Polytron in place, suitable for 601405040.
6.02008.030
Holder for homogenizer for Eco Titrations instrumentsHolder for homogenizer for fastening the Polytron in place, suitable for 601405060 titration vessel lid
6.02041.010
OMNIS sample rack, 9 x 250 mL, (PP)OMNIS sample rack for OMNIS Sample Robot Pick&Place, suitable for 9 sample beakers. The following sample beakers can be used: 6.01400.000, 6.01400.003, 6.01400.100.Plastic: Polypropylene (PP)
6.02041.020
OMNIS sample rack, 9 x 200 mL, (PP)OMNIS sample rack for OMNIS Sample Robot Pick&Place, suitable for 9 sample beakers. The following sample beakers can be used: 6.1459.310.Plastic: Polypropylene (PP)
6.02041.030
OMNIS sample rack, 16 x 120 mL, (PP)OMNIS sample rack for OMNIS Sample Robot Pick&Place, suitable for 16 sample beakers. The following sample beakers can be used: 6.01400.200, 6.01400.300, 6.01400.303.Plastic: Polypropylene (PP)
6.02041.040
OMNIS sample rack, 25 x 75 mL, (PP)OMNIS sample rack for OMNIS Sample Robot Pick&Place, suitable for 25 sample beakers. The following sample beakers can be used: 6.01402.000, 6.01402.003, 6.1459.400.Plastic: Polypropylene (PP)
6.02041.050
OMNIS sample rack, 9 x 150 mL, (PP)OMNIS sample rack for OMNIS Sample Robot Pick&Place, suitable for 9 sample beakers. The following sample beakers can be used: 150 mL beaker (tall shape and without spout).Plastic: Polypropylene (PP)
6.02041.060
OMNIS sample rack 50 x 6 mLOMNIS sample rack for OMNIS Sample Robot Oven, suitable for 50 sample vials (6.2419.000)
6.02041.080
OMNIS sample rack 77 x 8 mmOMNIS sample rack for OMNIS Sample Robot – NIR suitable for 77 disposable vials with an optical path length of 8 mm for measurements in transmission (6.7402.240).
- 8.909.50008.909.5000Brochure: 909 UV Digester
Sample preparation for the determination of traces of heavy metals
English
Other languages
- 8.912.50018.912.5001Brochure: 912/913/914 Meters – Measure pH, conductivity and dissolved oxygen as you need
This brochure gives you an overview about Metrohm's benchtop and portable meters for pH, redox potential, conductivity and dissolved oxygen measurement.
English
- 8.916.50048.916.5004Brochure: 916 Ti-Touch / 915 KF Ti-Touch / 917 Coulometer
"Reduce to the max" – this is the concept behind Ti-Touch. The compact titrator from Metrohm offers maximum performance in routine analysis in the smallest possible space:- Maximum system integration- Maximum data security and network integration – without a PC- Maximum work safety- Maximum operating convenience
English
Other languages
- 8.921.50098.921.5009Brochure: NIRS XDS MasterLab Analyzer – Rapid, nondestructive analyses of tablets, capsules and other solid-state dosage forms
The NIRS XDS MasterLab Analyzer enables rapid, nondestructiveanalysis of solid-state dosage forms such as tablets, capsules, film-coated tablets, gel tablets and gel capsules for manufacturers in the pharmaceutical industry. We are presenting the most important advantages and features for you in this brochure.
English
Other languages
- 8.921.50108.921.5010Brochure: NIRS XDS RapidContent Analyzer – Rapid, nondestructive analyses of solid and liquid substances
The NIRS XDS RapidContent Analyzer enables rapid, nondestructive analyses of solid and liquid formulations and substances. This brochure presents the advantages and features of the NIRS XDS RapidContent Analyzer for you in detail.
English
Other languages
- 8.921.50118.921.5011Brochure: NIRS XDS Interactance OptiProbe Analyzer – Robust measurement system for reaction monitoring in technical centers and pilot plant stations
The NIRS XDS Interactance OptiProbe Analyzer enables the simple and reliable monitoring of chemical reactions in technical centers and pilot plant stations. This brochure contains the most important advantages and features of the NIRS XDS Interactance OptiProbe Analyzer.
English
Other languages
- 8.921.50128.921.5012Brochure: NIRS XDS RapidLiquid Analyzer – Rapid, precise analyses of liquids and suspensions of all types
The NIRS XDS RapidLiquid Analyzer enables rapid, precise analyses of liquid formulations and substances. Precise measurement results at the push of a button make the NIRS XDS RapidLiquid Analyzer an equally reliable and simple solution for quality monitoring in laboratories and processes. This brochure shows you the most important advantages and features of the NIRS XDS RapidLiquid Analyzer.
English
Other languages
- 8.921.50138.921.5013Brochure: NIRS XDS MultiVial Analyzer – Rapid, nondestructive analyses of solids in vials
The NIRS XDS MultiVial Analyzer enables rapid, nondestructive analyses of the identity and quality of solid material samples that are transferred into vials. This brochure explains the advantages and features of the NIRS XDS MultiVial Analyzer for you.
English
Other languages
- 8.921.50148.921.5014Brochure: NIRS XDS Transmission OptiProbe Analyzer – Robust measurement system for reaction monitoring of liquids in technical centers and pilot plant stations
The NIRS XDS Transmission OptiProbe Analyzer enables efficient determination of the composition of aqueous products, clear liquids, solvents and viscous samples. This brochure details the advantages and features of the NIRS XDS Transmission OptiProbe Analyzer.
English
Other languages
- 8.921.50158.921.5015Brochure: NIRS XDS SmartProbe Analyzer – Robust and flexible measuring system for quality control of solid and liquid substances
The NIRS XDS SmartProbe Analyzer enables rapid, nondestructive analyses of solid and liquid substances and formulations. This brochure contains information regarding the advantages and features of the NIRS XDS SmartProbe Analyzer.
English
Other languages