Search
Market-leading solutions
Product families (69)Product configurations for any application
Product models (712)Tried-and-tested applications
Applications (2250)Electrodes
Electrodes (509)Columns
Columns (155)Accessories
Accessories (2246)Software
Software (266)Manuals & brochures
Documents (2601)News
News (54)Inspiring industry insights
Insights (177)Unmatched support & service
Support & service (79)Other content
Items (86)On-demand webinars
Webinars (72)2.814.0010
814 USB Sample Processor (1T/1P)USB Sample Processor with one workstation and one built-in membrane pump for the automatic processing of routine samples in series with small to medium quantities. In addition to the built-in pump, an additional one (membrane or peristaltic) and up to three dosing devices for Liquid Handling tasks can be connected.Because of the multitude of application variants, rack, stirrer, titration head, Swing Head and sample vessels must be tailored to the application and ordered separately.The control is "stand alone" using Touch Control. The following software products can be selected for the PC control: tiamo™ titration software, MagIC Net chromatography software, viva voltammetry software, or OMNIS.
2.814.0020
814 USB Sample Processor (1T/2P)USB Sample Processor with one workstation and two built-in membrane pumps for the automatic processing of routine samples in series with small to medium quantities. In addition to the built-in pumps, up to three dosing devices for Liquid Handling tasks can be connected.Because of the multitude of application variants, rack, stirrer, titration head, Swing Head and sample vessels must be tailored to the application and ordered separately. The control is "stand alone" using Touch Control. The following software products can be selected for the PC control: tiamo™ titration software, MagIC Net chromatography software, viva voltammetry software, or OMNIS.
2.814.0030
814 USB Sample Processor (1T/0P)USB Sample Processor with one workstation for the automatic processing of routine samples in series with small to medium quantities. Up to two pumps (membrane or peristaltic) and three dosing devices for Liquid Handling tasks can be connected.Because of the multitude of application variants, rack, stirrer, titration head, Swing Head and sample vessels must be tailored to the application and ordered separately.The control is "stand alone" using Touch Control. The following software products can be selected for the PC control: tiamo™ titration software, MagIC Net chromatography software, viva voltammetry software, or OMNIS.
2.814.0110
814 USB Sample Processor (2T/2P)USB Sample Processor with two workstations and two built-in membrane pumps for the automatic processing of routine samples in series with small to medium quantities. In addition to the built-in pumps, two additional pumps (membrane or peristaltic) and up to three dosing devices for Liquid Handling tasks can be connected.Because of the multitude of application variants, rack, stirrer, titration head, Swing Head and sample vessels must be tailored to the application and ordered separately.The control is "stand alone" using Touch Control. The following software products can be selected for the PC control: tiamo™ titration software, MagIC Net chromatography software, viva voltammetry software, or OMNIS.
2.814.0120
814 USB Sample Processor (2T/4P)USB Sample Processor with two workstations and four built-in membrane pumps for the automatic processing of routine samples in series with small to medium quantities. In addition to the built-in pumps, up to three dosing devices for Liquid Handling tasks can be connected.Because of the multitude of application variants, rack, stirrer, titration head, Swing Head and sample vessels must be tailored to the application and ordered separately.The control is "stand alone" using Touch Control. The following software products can be selected for the PC control: tiamo™ titration software, MagIC Net chromatography software, viva voltammetry software, or OMNIS.
2.814.0130
814 USB Sample Processor (2T/0P)USB Sample Processor with two workstations for the automatic processing of routine samples in series with small to medium quantities. Up to four pumps (membrane or peristaltic) and three dosing devices for Liquid Handling tasks can be connected.Because of the multitude of application variants, rack, stirrer, titration head, Swing Head and sample vessels must be tailored to the application and ordered separately.The control is "stand alone" using Touch Control. The following software products can be selected for the PC control: tiamo™ titration software, MagIC Net chromatography software, viva voltammetry software, or OMNIS.
2.815.0010
815 Robotic USB Sample Processor XL (1T/1P)Robotic USB Sample Processor XL with one workstation and one built-in membrane pump for the automatic processing of routine samples in series with large quantities and for complex sample preparation or parallel runs. In addition to the built-in pump, an additional one (membrane or peristaltic) and up to three dosing devices for Liquid Handling tasks can be connected.Because of the multitude of application variants, rack, stirrer, titration head, robotic arm, Swing Head and sample vessels must be tailored to the application and ordered separately.The control is "stand alone" using Touch Control. The following software products can be selected for the PC control: tiamo™ titration software, MagIC Net chromatography software, viva voltammetry software, or OMNIS.
2.815.0020
815 Robotic USB Sample Processor XL (1T/2P)Robotic USB Sample Processor XL with one workstation and two built-in membrane pumps for the automatic processing of routine samples in series with large quantities and for complex sample preparation or parallel runs. Up to three dosing devices for Liquid Handling tasks can be connected.Because of the multitude of application variants, rack, stirrer, titration head, robotic arm, Swing Head and sample vessels must be tailored to the application and ordered separately.The control is "stand alone" using Touch Control. The following software products can be selected for the PC control: tiamo™ titration software, MagIC Net chromatography software, viva voltammetry software, or OMNIS.
2.815.0030
815 Robotic USB Sample Processor XL (1T/0P)Robotic USB Sample Processor XL with one workstation for the automatic processing of routine samples in series with large quantities and for complex sample preparation or parallel runs. Up to two pumps (membrane or peristaltic) and three dosing devices for Liquid Handling tasks can be connected.Because of the multitude of application variants, rack, stirrer, titration head, robotic arm, Swing Head and sample vessels must be tailored to the application and ordered separately.The control is "stand alone" using Touch Control. The following software products can be selected for the PC control: tiamo™ titration software, MagIC Net chromatography software, viva voltammetry software, or OMNIS.
2.815.0110
815 Robotic USB Sample Processor XL (2T/2P)Robotic USB Sample Processor XL with two workstations and two built-in membrane pumps for the automatic processing of routine samples in series with large quantities and for complex sample preparation or parallel runs. In addition to the built-in pumps, up to two additional pumps (membrane or peristaltic) and three dosing devices for Liquid Handling tasks can be connected.Because of the multitude of application variants, rack, stirrer, titration head, robotic arm, Swing Head and sample vessels must be tailored to the application and ordered separately.The control is "stand alone" using Touch Control. The following software products can be selected for the PC control: tiamo™ titration software, MagIC Net chromatography software, viva voltammetry software, or OMNIS.
- AB-242AB-242Determination of tungsten by anodic stripping voltammetry at the Ultra Trace graphite RDE
The method described allows the determination of W(VI) traces in the range 0.2 to 50 µg/L (ppb). Traces of organic compounds present in the samples (e.g. natural waters) interfere. They have to be removed by UV digestion (e.g. 705 UV Digester). Interference by Fe(III) up to a concentration of 100 mg/L is eliminated by reduction to Fe(lI) with ascorbic acid. If the amount of Cu(II) in the sample exceeds the amount of W(VI) by a factor of 200 or more, the Cu ions have to be bound with thiourea. Moreover, the concentration of Cu(II) should not exceed 5 mg/L. The determination is made by adsorptive stripping analysis in the DP mode.
- AB-243AB-243Determination of chromium by adsorptive stripping voltammetry at the Ultra Trace graphite RDE
The method describes the determination of Cr traces in a range between 1 ... 250 μg/L. The method is based on the adsorption of a Cr(lll)-diphenylcarbazonate complex on the Ultra Trace graphite rotating disk electrode (RDE). Organic compounds present in samples (e.g. natural waters) have a strong interfering effect. So they have to be removed by e.g. UV digestion. The determination is made by adsorptive stripping voltammetry in the DC (direct current) measuring mode. Purging with nitrogen is not necessary. The determinations work well also in high salt concentration solutions.
- AB-249AB-249Determination of free and residual chlorine based on DIN EN ISO 7393-1 and APHA 4500-Cl
Chlorine is frequently added to drinking water for disinfection. Depending on the reactivity and the concentration of chlorine, toxic disinfection by-products (DBPs) can thereby be released. Therefore, it is necessary to strictly control the chlorine concentration in the drinking water. This Application Bulletin shows how to determine the chlorine concentration according to three standard methods: DIN EN ISO 7939-1, APHA 4500-Cl Method B, and APHA 4500-Cl Method I.
- AB-250AB-250Polarographic determination of diazepam in body fluids and pharmaceutical preparations
Diazepam belongs to the 1,4-benzodiazepine group of compounds, which are used for medical purposes as tranquilizers and antidepressants. This Bulletin describes the determination of diazepam in tablets and body fluids (blood, serum, urine) by means of differential pulse polarography. If a Britton-Robinson buffer pH = 2.8 with a methanol volume fraction of 20% is used as the supporting electrolyte then a pronounced reduction peak is obtained at -0.73 V; this allows diazepam concentrations even below 0.05 µg/mL to be determined in blood. The necessary sample preparation steps are also dealt with in this Bulletin.
- AB-251AB-251Polarographic determination of cinchocaine (dibucaine) in pharmaceutical preparations
Cinchocaine (dibucaine) is used in the form of ointments or injection solutions as a local anaesthetic. Its base is soluble in diethyl ether; its hydrochloride, on the other hand, is insoluble in diethyl ether but easily soluble in water. This Bulletin describes the determination of cinchocaine in ointments, creams and injection solutions by means of differential pulse polarography. An acetate buffer pH = 4.8 is used as the supporting electrolyte. The limit of quantitation and the linear working range of the method are given. The necessary sample preparation steps are also dealt with in this Bulletin.
- AB-254AB-254Determination of zinc, cadmium and lead by anodic stripping voltammetry at a mercury film electrode
This Application Bulletin describes the determination of zinc at a mercury film electrode (MFE). Zinc can also be determined simultaneously with cadmium and lead. The determination of copper at the MFE is not possible. The mercury film is plated ex-situ on a glassy carbon electrode and can be used for half a day up to one day.Zinc can be determined at the mercury film electrode by anodic stripping voltammetry (ASV). The presence of copper, which is naturally present in many samples, affects the determination of zinc due to the formation of an intermetallic compound. As a result the determined concentrations of zinc are too low. The addition of gallium can eliminate the interference to a certain extent since the intermetallic complex of gallium and copper is more stable than the complex of zinc and copper.With a deposition time of 10 s, the limit of detection is β(Zn2+) = 0.15 μg/L. The linear working range goes up to approx. 300 μg/L.With the deposition time of 10 s the method is suitable for samples between 10 μg/L and 150 μg/L Zn content. For samples with lower concentrations the results are more reliable if the deposition time is increased to e.g. 30 s. Samples with higher concentrations have to be diluted.
- AB-264AB-264Titrimetric methods for the determination of betains
The two potentiometric titration methods described here allow the determination of the content of commercial betaine solutions. Neither method is suitable for determining the betaine content of formulations. The possibilities and limits of both methods are described and distinctive features and possible sources of interference are mentioned. The Bulletin explains the most important theoretical principles and is intended to help users to develop their own product-specific titration methods.
- AB-265AB-265Hamilton PRP-X100 IC anion column (6.1005.000)
This Bulletin describes the determination by ion chromatography of anions, particularly fluoride, chloride, nitrite, bromide, nitrate, and sulfate using the Hamilton PRPX100 IC anion column without chemical suppression.
- AB-266AB-266Determination of titanium by adsorptive stripping voltammetry
This Application Bulletin describes the determination of titanium by adsorptive stripping voltammetry (AdSV) using mandelic acid as complexing agent. The method is suitable for the analysis of ground, drinking, sea, surface and cooling waters, in which the concentration of titanium is of importance. The methods can, of course, also be used for the trace analysis in other matrices.The limit of detection is approx. 0.5 µg/L.
- AB-268AB-268Potentiometric titration of surfactants and pharmaceuticals – an overview
The present Bulletin offers an overview of the multitude of surfactants and pharmaceuticals that can be determined with potentiometric titration. Metrohm provides five different surfactant electrodes for indicating the titration endpoint: the Ionic Surfactant, the High Sense, the Surfactrode Resistant, the Surfactrode Refill and the NIO Surfactant electrode. The manufacture of the respective titrants and their titer determination are described in detail. In addition to this, the Bulletin contains a tabular overview of more than 170 proven applications from the area of surfactant and pharmaceutical analysis. This guideline leads you reliably to your destination: At a glance you can see from the table which surfactant electrode and which titrant are optimally suitable for your product.
BWT-840000591
Raman Chemicals Spectral LibraryRaman Chemicals Spectral Library for portable Raman instruments, with around 1,150 spectra of common chemicals, narcotics, explosives, solvents and plastics. Supported in BWID Version 2.02 and higher.
BWT-840000843
Raman Gemstone Spectral LibraryRaman Gemstone Spectral Library for BWID and portable Raman instruments with > 450 spectra from Gem Expert and from Japan Germany Gemmological Laboratory. Library supported in BWID Version 2.02 or higher.
BWT-840000847
Raman Explosives Spectral LibraryRaman Explosives Spectral Library for portable Raman instruments including more than 180 spectra. Supported in BWID Version 2.02 and higher. Note: This item may be subject to Export control to some territories.
BWT-840000848
Raman Chemicals and Narcotics Spectral LibraryRaman Chemicals Spectral Library for portable Raman instruments, with more than 1,100 spectra of common and toxic chemicals, narcotics, solvents and plastics. Supported in BWID Version 2.02 and higher.
BWT-840000939
TID-EX Software Drive and Product ManualUSB flash drive containing TacticID-1064 PC software TID-EX installation package and TacticID-1064 product manuals.
BWT-840000971
NanoRam-1064 Software and Product ManualNanoRam-1064 accessories: USB flash drive containing NID EX software installation package; NanoRam-1064 Product Manual (PDF); NID EX Installation Instructions (PDF).
BWT-840000974
Complete Raman Spectral Library (TacticID Plus)Complete Raman Spectral Library for TacticID Plus with > 10,000 spectra of common chemicals, narcotics, solvents and plastics. Includes NFPA704 and GHS safety instructions.
BWT-840000975
Common Chemicals, Narcotics, Explosives, Solvents and Plastics Spectral Library (TacticID Plus)Raman Spectral Library for TacticID Plus with more than 1,200 spectra of common chemicals, narcotics, explosives, solvents and plastics. Includes NFPA704 and GHS safety instructions. May be subject to export control.
BWT-840000976
Common Chemicals, Narcotics, Solvents and Plastics Spectral Library (TacticID Plus)Raman Spectral Library for TacticID Plus with more than 1,180 spectra of common chemicals, narcotics, solvents and plastics. Includes NFPA704 and GHS safety instructions.
BWT-840000977
Raman Explosives Spectral Library (TacticID Plus)Raman Explosives Spectral Library TacticID Plus including > 180 spectra. Includes NFPA704 and GHS safety instructions.Note: This item may be subject to Export control to some territories.
6.0279.300
iSolvotrodeIntelligent, combined pH electrode with integrated memory chip for storing sensor data for all non-aqueous acid/base titrations. The glass membrane is optimized for poorly conducting solutions, and thanks to the flexible ground-joint diaphragm, the electrode is well suited for contaminated samples. This electrode can be used with non-aqueous reference electrolytes (lithium chloride or tetraethylammonium bromide). Storage in the respective reference electrolyte.iTrodes can be connected to Titrando, Ti-Touch, or 913/914 meters.
6.0280.300
iEcotrode PlusIntelligent, combined pH electrode with integrated memory chip for storing of sensor data. This electrode is suitable for aqueous acid/base titrations. The fixed ground-joint diaphragm is insensitive to contamination.Reference electrolyte: c(KCl) = 3 mol/L, storage in storage solution.iTrodes can be connected to Titrando, Ti-Touch or 913/914 meters.
6.0301.100
Separate Pt-wire electrodeElectrode tip made of Pt wire. This electrode is used as an auxiliary electrode for differential potentiometry.
6.0309.100
Double Pt sheet electrodeGlass shaft electrode with two platinum sheets (0.15 x 8 x 8 mm) which are polarized for redox titrations (bivoltammetric titration). This electrode is well suited for Vitamin C determination; Coulometric nitrogen determination; Bromine index; Sulfurous acid (SO2) in wine; Oxygen content according to Winkler;
6.0331.000
Separate Pt Rod ElectrodeThis metal electrode has to be used in combination with a reference electrode (c(KCl) = 3 mol/L as reference electrolyte) and is well suited: for redox titrations; as an auxiliary electrode for differential potentiometry; The robust shaft made of polypropylene and the metal rod can be replaced separately.
6.0331.010
Separate Ag-rod electrodeThis metal electrode has to be used in combination with a reference electrode (c(KNO3) = 1 mol/L as reference electrolyte) and is well suited for precipitation titrations (titrant silver nitrate). The robust shaft made of polypropylene and the metal rod can be replaced separately.
6.0331.010BR
Separate Ag-rod electrode with AgBr coatingThis metal electrode has to be used in combination with a reference electrode (c(KNO3) = 1 mol/L as reference electrolyte) and is well suited for precipitation titrations (titrant silver nitrate). The robust shaft made of polypropylene and the metal rod can be replaced separately. The silver rod is coated with bromide (AgBr) for higher sensitivity.
6.0331.010S
Separate Ag-rod electrode with Ag2S coatingThis metal electrode has to be used in combination with a reference electrode (c(KNO3) = 1 mol/L as reference electrolyte) and is well suited for precipitation titrations (titrant silver nitrate). The robust shaft made of polypropylene and the metal rod can be replaced separately. The silver rod is coated with sulfide (Ag2S) for higher sensitivity.
6.0338.100
Double Pt-wire electrode for volumetryIndicator electrode used for volumetric Karl Fischer titration.
6.0340.000
Double Pt-wire electrode for sample changer (fixed cable)Indicator electrode (diameter = 5.3 mm, fixed cable 2 m) used for automated Karl Fischer titration.
6.01805.110
PTFE tubing with Luer 80 cmTubing for the connection between peristaltic pump 2 or 4 in the pump module with the distributor (aspiration) on the Pick&Place module.
6.01805.120
PTFE tubing with Luer 2.5 mTubing for the connection between the canister and the peristaltic pump in the pump module.
6.01805.130
3/250 mm PTFE tubing with screw nippleAspiration tubing with screw nipple to connect the reagent bottle to the Siphon Beaker.
6.01806.000
PEEK capillary, 0.18 mm ID / 2 mFor use in the high-pressure flow path, e.g. as preheating capillary for Metrosep Carb 2 columns in the 2 mm version (6.01090.2x0).
6.01807.000
Adsorption cartridgeAdsorption cartridge for OMNIS Solvent Module or Solvent Pump, for filling with 6.2811.000 molecular sieve.
6.01807.010
Adsorber cartridge for OMNIS Oven ModuleAdsorber cartridge suitable for the OMNIS Oven Module
6.01808.010
Y tubing connector, PP, 3 x 7-8 mmConnector for waste tubing
6.01816.010
Silicone tubing, 8/12 mm, 2 mDrainage tubing
6.01829.010
Replacement tubing setReplacement tubing for the 6.1446.200 heating tubing stopper or for the 6.1446.220 Reagent Replacement Solvent Module stopper
6.01900.010
Stirring propeller 30 mm ETFEStirring propeller 30 mm ETFE with adjustable height for use with Rod Stirrer "Titrator" or Rod Stirrer "Sample Robot"