Search
Market-leading solutions
Product families (69)Product configurations for any application
Product models (712)Tried-and-tested applications
Applications (2250)Electrodes
Electrodes (509)Columns
Columns (155)Accessories
Accessories (2246)Software
Software (266)Manuals & brochures
Documents (2601)News
News (54)Inspiring industry insights
Insights (177)Unmatched support & service
Support & service (79)Other content
Items (86)On-demand webinars
Webinars (72)2.803.0010
803 TI Stand with stirrer and pumpCompact titration stand with magnetic stirrer and built-in pump for solvent addition and aspiration of the titration vessel contents. Suitable for Karl Fischer titrations with Titrandos. MSB connection.Including comprehensive accessories, solvent bottle and waste bottle.
2.804.0010
804 Ti Stand without stand rodTitration stand and controller for 802 Stirrer. The 804 Ti Stand together with the optional 802 Stirrer provides an alternative to the magnetic stirrer. Without stand.
2.804.0040
804 Ti Stand with standTitration stand and controller for 802 Rod Stirrer. The 804 Ti Stand together with the optional 802 Rod Stirrer provides an alternative to the magnetic stirrer. Ti Stand with base plate, support rod and electrode holder.
2.805.0010
805 DosimatDosing device for the Titrando and Sample Processors with read/write hardware for intelligent Exchange Units. With permanently attached cable. Without Exchange Unit.
2.810.0010
810 Sample ProcessorSample Processor for the automated analysis of routine samples using 916 Ti-Touch or 915 KF Ti-Touch.Sample Processor with one workstation and one built-in membrane pump for the automatic processing of potentiometric as well as Karl Fischer titrations, in series with small to medium quantities. In addition to the built-in pump, an additional one (membrane or peristaltic) and up to three dosing devices for Liquid Handling tasks can be connected.Because of the multitude of application variants, rack, stirrer, titration head, Swing Head and sample vessels must be tailored to the application and ordered separately.
2.811.0014
811 Online IC Process Analyzer (1 channel, 230 V)Single-channel online ion chromatograph with Inline Calibration and sample preconcentration for the determination of cations or anions with and without suppression down to the ultratrace range. Ten independent sample flows. 230 V.
2.811.0015
811 Online IC Process Analyzer (1 channel, 115 V)Single-channel online ion chromatograph with Inline Calibration and sample preconcentration for the determination of cations or anions with and without suppression down to the ultratrace range. Ten independent sample flows. 115 V.
2.811.0024
811 Online IC Process Analyzer (2 channels, 230 V)2-Channel online ion chromatograph with inline calibration and sample preconcentration for simultaneous analysis of cations and anions with and without suppression down to the ultra-trace range. 10 independent sample flows. 230 V.
2.811.0025
811 Online IC Process Analyzer (2 channels, 115 V)2-Channel online ion chromatograph with inline calibration and sample preconcentration for simultaneous determination of cations and anions with and without suppression down to the ultra-trace range. 10 independent sample flows. 115 V.
2.813.0020
813 VA Compact AutosamplerAutosampler for the basic automation of the VA systems, with integrated peristaltic pump for sample transfer. The sample changer can be used in combination with the 746 VA Trace Analyzer or the 797 VA Computrace. Capacity: 18 samples.
- AB-224AB-224Determination of pyridoxine (vitamin B6) by polarography
This Application Bulletins describes the polarographic determination of pyridoxine (vitamin B6). The method given allows determination in monovitamin and in some multivitamin preparations. The linear range of the analysis is also specified. The limit of detection is approx. 100 µg/L pyridoxine · HCI.
- AB-225AB-225Simple wine analysis
The Bulletin describes the determination of the following parameters in wine: pH value, total titratable acid, free sulfurous acid, total sulfurous acid as well as ascorbic acid (vitamin C) and other reductones.
- AB-226AB-226Determination of arsenic by stripping voltammetry at the rotating gold electrode
This Bulletin describes the determination of arsenic by anodic stripping voltammetry (ASV) at the rotating gold electrode. A determination limit of 0.5 μg/L can be achieved with 10 mL sample solution. A differentiation between the As(III) concentration and the total arsenic concentration can be made by appropriate selection of the deposition potential. The analyses are performed with a special gold electrode whose active surface is located laterally; c(HCl) = 5 mol/L is used as supporting electrolyte. For the determination of the total arsenic content, As(III) and As(V) are reduced at -1200 mV by nascent hydrogen to As0, which is preconcentrated on the electrode surface. If the deposition is carried out at -200 mV then only As(III) is reduced; this allows the differentiation between total arsenic and As(III). During the subsequent voltammetric determination the preconcentrated As0 is again oxidized to As(III).
- AB-230AB-230Potentiometric determination of nonionic surfactants based on polyoxyethylene adducts with the NIO electrode
The titrimetric determination of nonionic surfactants on the basis of polyoxyethylene adducts (POE adducts) is described in the Bulletin. The basis for the determination is the transfer of the nonionic surfactant into a pseudo-cation compound and its precipitation titration with sodium tetraphenylborate (Na-TPB). The NIO electrode is used for the indication of the potentiometric titration. This Bulletin describes determinations in raw products, formulations and wastewater and draws attention to special features, possibilities, limits and disruptions.
- AB-231AB-231Determination of zinc, cadmium, lead, copper, thallium, nickel and cobalt in water samples by anodic and adsorptive stripping voltammetry according to DIN 38406-16
The standard method postulated by DIN 38406 Part 16 describes the determination of Zn, Cd, Pb, Cu, Tl, Ni, and Co in drinking, ground, surface and precipitation (e.g. rain) water. Because the presence of organic substances in the water samples can strongly interfere with the voltammetric determination, a pretreatment with UV digestion using hydrogen peroxide is necessary. This digestion ensures the elimination of all organic substances without introduction of blank values. These methods can, of course, also be applied for trace analysis in other materials, e.g. trace analysis in the production of semiconductor chips based on silicon. Zn, Cd, Pb, Cu, and Tl are determined on the HMDE by means of anodic stripping voltammetry (ASV), Ni and Co by means of adsorptive stripping voltammetry (AdSV).
- AB-232AB-232Determination of antioxidant activity in accordance with the Rancimat method
The effectiveness of antioxidants can be expressed as antioxidant activity. It can be readily determined using the Rancimat method. This is accomplished by first determining the induction time of a mixture made up of hog fat and the antioxidant to be investigated and then by determining the corresponding time for hog fat alone. The quotient expresses the efficiency of the respective antioxidant and is referred to as the antioxidant activity index (AAI).This Application describes the determination of the antioxidant activity index of five common antioxidants.
- AB-233AB-233Potentiometric determination of anionic and cationic surfactants with surfactant electrodes
Anionic surfactants can be titrated with cationic surfactants and vice-versa. The Bulletin describes a multitude of substances that can be determined in this fashion and specifies the respective working conditions and parameters. In contrast to the classic two-phase titration in accordance with Epton, the titration with the anionic and cationic surfactants electrodes can be performed without chloroform. Furthermore, the equivalence point of the titration is difficult to determine in some cases with the Epton method and the titration cannot be automated.In many cases, a surfactant ISE is a remedy that is both environmentally friendly and suitable here. It was developed specially for application with potentiometrically indicated surfactant determinations.
- AB-235AB-235Potentiometric titration of calcium (magnesium) in dairy products
This Bulletin describes a simple method for the determination of the calcium content in dairy products. The use of CuEGTA and the ion-selective copper electrode (Cu ISE) as indicator electrode allows the determination to be performed without time-consuming sample preparation. If the complexing agent EDTA is used as titrant instead of EGTA, the sum of calcium and magnesium is obtained. The magnesium content can then be calculated from the difference between the results of the two titrations.
- AB-237AB-237Determination of the stability index of solid foods with the Rancimat method
Determination of the oxidation stability of foods with a low fat content is a challenge. As an alternative, the oxidation stability can be specified indirectly. To accomplish this, a determination is made as to the extent that a sample that has been mixed with a fat as a standard solution, e.g., hog fat, will change the oxidation stability of that standard solution. This is accomplished by first determining the induction time of the mixture made up of hog fat and the sample and then by determining the corresponding time for the lard alone. The quotient is referred to as the stability index (SI).
- AB-241AB-241Determination of cadmium and lead by anodic stripping voltammetry at a mercury film electrode
This Application Bulletin describes the determination of cadmium and lead at a mercury film electrode (MFE) by anodic stripping voltammetry (ASV). The mercury film is plated ex situ on a glassy carbon electrode and can be used for up to one day. With a deposition time of 30 s, the limit of detection is ß(Cd2+) = 0.02 µg/L and ß(Pb2+) = 0.05 µg/L. The linear working range for both elements goes up to approx. 50 μg/L using the same deposition time.
6.6081.020
USB flash drive for Eco KF TitratorStorage medium for Eco KF Titrator
6.6081.030
USB flash drive for Eco CoulometerStorage medium for Eco Coulometer
6.6082.000
Portable VA Analyzer Software 1.1PC program for the 946 Portable VA Analyzer. The range of functions of the software include instrument and measuring stand control, data acquisition and evaluation, calculation of results and generation of reports.Easy-to-operate method editor; Method templates for all important applications; Display of measurement and calibration curves and analysis result; Dialog languages: English, Chinese; Supplied on USB memory stick;
6.6090.100
Metrohm IC Driver 1.0, ICP-MS MassHunterSoftware drivers for integrating Metrohm IC instruments in Agilent's ICP-MS MassHunter Software 5.3 and higher.Learn more about the coupling of IC and mass spectrometers
BWT-810000044
BWSpec SoftwareBWSpec® is B&W Tek’s general spectroscopy software for instrument control and data acquisition, including real-time peak analysis and trending. BWSpec is the operating software included with the purchase of all B&W Tek portable Raman systems and spectrometer products. It is designed with features for broad range applications, performing complex measurements and calculations at the click of a button. It supports multiple data formats and provides the option to optimize measurement parameters, such as integration time and laser output power control. In addition to data acquisition and data processing, it also offers automatic dark removal, spectral smoothing, baseline correction, as well as peak monitoring and trending.
BWT-840000126
BWID Standard Raman ID SoftwareData acquisition, material identification and reporting software for B&W Tek portable Raman spectrometers to rapidly identify or verify materials based on user-built libraries, proprietary B&W Tek and third-party libraries. Includes system performance tests. One user license provided. Free upgrades included within one year of purchase date.
BWT-840000127
BWID Pharma Raman ID SoftwareData acquisition and material identification software for B&W Tek portable Raman spectrometers to rapidly identify or verify materials based on user-built libraries, proprietary B&W Tek and third-party libraries. Meets all the requirements of FDA 21 CFR Part 11, including system access security, audit trail of data activities, and system performance tests. One user license provided. Free upgrades included within one year of purchase date.
BWT-840000172
Raman Hydrocarbons Spectral LibraryRaman Hydrocarbons Spectral Library (portable instruments) for use in the BWID software; 576 Spectra.
BWT-840000280
GemID SoftwareData acquisition and identification software for the analysis of gemstones and minerals with B&W Tek portable Raman spectrometers. Includes Raman Spectral Library and images of more than 450 gemstones from Gem Expert and Japan Germany Gemmological Laboratory. One user license provided. Free upgrades included within one year of purchase date.
BWT-840000305
NanoRam ID SoftwareNID software for use on the PC for NanoRam account management, test result review, access to test reports and the Audit Trail.
6.0257.600
Aquatrode Plus with Pt1000Combined pH electrode with integrated Pt1000 temperature sensor for pH measurements/titrations in ion-deficient aqueous media (e.g., drinking water, process water). This electrode shows a very short response time in these samples. The fixed ground-joint diaphragm is insensitive to contamination. When c(KCl) = 3 mol/L is used as bridge electrolyte, storage in storage solution is recommended.The bridge electrolyte can be easily replaced with a chloride-free electrolyte (e.g., potassium nitrate c(KNO3) = 1 mol/L (6.2310.010)), storage in the used bridge electrolyte.
6.0258.010
Unitrode with Pt1000 (fixed cable 1.2 m, 2 mm)Combined pH electrode with integrated Pt1000 temperature sensor and fixed cable (1.2 m, diameter banana plug 2 mm). This electrode is particularly suitablefor pH measurements and titrations in difficult, viscous, or alkaline samples; at elevated temperatures; for long-term measurements; The fixed ground-joint diaphragm is insensitive to contamination.Reference electrolyte: c(KCl) = 3 mol/L, storage in storage solution.Alternatively: reference electrolyte for measurements at T>80°C: Idrolyte, storage in Idrolyte.
6.0258.600
Unitrode with Pt1000Combined pH electrode with integrated Pt1000 temperature sensor for pH measurements/titrations. This electrode is particularly suitable:for pH measurements and titrations in difficult, viscous, or alkaline samples; at elevated temperatures; for long-term measurements; The fixed ground-joint diaphragm is insensitive to contamination.Reference electrolyte: c(KCl) = 3 mol/L, storage in storage solution.Alternatively: reference electrolyte for measurements at T>80°C: Idrolyte, storage in Idrolyte.
6.0259.100
UnitrodeCombined pH electrode for pH titrations. This electrode is particularly suitable:for pH titrations in difficult, viscous, or alkaline samples; at elevated temperatures; The fixed ground-joint diaphragm is insensitive to contamination.Reference electrolyte: c(KCl) = 3 mol/L, storage in storage solution.Alternatively: reference electrolyte for measurements at T>80°C: Idrolyte, storage in Idrolyte.
6.0260.010
Unitrode easyClean mit Pt1000 (fixed cable 1.2 m)Combined pH electrode with easyClean diaphragm, integrated Pt1000 temperature sensor, and fixed cable (1.2 m). It is particularly suitable:for pH measurements and titrations in difficult, viscous, or alkaline samples; at elevated temperatures; for long-term measurements; The easyClean diaphragm can be easily cleaned even in the case of heavily contaminating samples.Reference electrolyte: c(KCl) = 3 mol/L, storage in storage solution.Alternatively: reference electrolyte for measurements at T>80 °C: Idrolyte, storage in Idrolyte.The Unitrode easyClean with Pt1000 is also available under the article number 6.0260.020 with a fixed cable length of 2.0 m.
6.0260.020
Unitrode easyClean with Pt1000 (fixed cable 2 m)Combined pH electrode with easyClean diaphragm, integrated Pt1000 temperature sensor, and fixed cable (2.0 m). This electrode is particularly suitable: for automated pH measurements and titrations in difficult, viscous, or alkaline samples; at elevated temperatures; for long-term measurements; The easyClean diaphragm can be easily cleaned even in the case of heavily contaminating samples.Reference electrolyte: c(KCl) = 3 mol/L, storage in storage solution.Alternatively: reference electrolyte for measurements at T>80°C: Idrolyte, storage in Idrolyte.
6.0262.100
Ecotrode PlusCombined pH electrode for aqueous acid/base titration. The fixed ground-joint diaphragm is insensitive to contamination. Reference electrolyte: c(KCl) = 3 mol/L, storage in storage solution.
6.0269.100
EtOH-TrodeCombined pH electrode with double-junction system for pH measurements in nonaqueous media (e.g., for pHe in ethanol).The electrode is equipped with a fixed ground-joint diaphragm which is insensitive to contamination, and the bridge electrolyte can be freely chosen (aqueous or nonaqueous).When c(KCl) = 3 mol/L is used as bridge electrolyte, storage in storage solution is recommended. When a different bridge electrolyte is used, storage in the respectively used bridge electrolyte solution is recommended.The two chambers for reference electrolyte ("INNER FILLING") and bridge electrolyte ("OUTER FILLING") are each filled with c(KCl) = 3 mol/l at the time of delivery.
6.0277.300
iAquatrode Plus with Pt1000Intelligent, combined pH electrode with integrated memory chip for storing sensor data and with Pt1000 temperature sensor for pH measurements/titrations in ion-deficient aqueous media (e.g., drinking water, process water). This electrode shows a very short response time in these samples. The fixed ground-joint diaphragm is insensitive to contamination. When c(KCl) = 3 mol/L is used as bridge electrolyte, storage in storage solution is recommended.The bridge electrolyte can be easily replaced with a chloride-free electrolyte (e.g., potassium nitrate c(KNO3) = 1 mol/L (6.2310.010)). Storage in the used bridge electrolyte.iTrodes can be connected to Titrando, Ti-Touch, or 913/914 meters.
6.0278.300
iUnitrode with Pt1000Intelligent, combined pH electrode with integrated memory chip for storing sensor data and Pt1000 temperature sensor. This electrode is particularly suitable:for pH measurements and titrations in difficult, viscous, or alkaline samples; at elevated temperatures; for long-term measurements; The fixed ground-joint diaphragm is insensitive to contamination.Reference electrolyte: c(KCl) = 3 mol/L, storage in storage solution.Alternatively: reference electrolyte for measurements at T>80°C: Idrolyte, storage in Idrolyte.iTrodes can be connected to Titrando, Ti-Touch or 913/914 meters.
6.01801.020
Pharm-A-line pump tubing to the peristaltic pump moduleThe pump tubing comes pre-equipped with adapters that permit direct installation in the peristaltic pump of the pump module. The Pharm-A-line pump tubing is used for the transport of both aqueous and nonaqueous solutions and must be operated in connection with the white press clamp in the pump module.
6.01803.000
Silicone tubing 8/12 2.5 mSilicone tubing for connecting to the drainage of the Pick&Place module or pump module in order to channel any solution overflows that may occur safely into the waste canister.
6.01804.210
PVC tubing 4/6 0.35 mFor tubing connections to the OMNIS Solvent Module or the Solvent Pump.
6.01804.410
Drain channel for OMNIS Sample Robot SThe drain channel is mounted behind the workstations of the OMNIS Sample Robot S and, in case of an error, collects any overflowing solution in order to channel it safely and contact-free through tubing into a waste canister.
6.01804.430
Drain channel for OMNIS Sample Robot M/LThe drain channel is mounted behind the workstations of the OMNIS Sample Robot M/L and, in case of an error, collects any overflowing solution in order to channel it safely and contact-free through tubing into a waste canister.
6.01804.460
Drain channel for OMNIS Sample Robot M/L WSMThe drain channel is mounted behind the workstations of the OMNIS Sample Robot WSM M/L and, in case of an error, collects any overflowing solution in order to channel it safely and contact-free through tubing into a waste canister.
6.01804.500
Tubing adapter for drainage tubingTubing adapter for drainage tubing on Pick&Place modules and pump modules in the OMNIS Sample Robot Pick&Place.
6.01805.000
FEP tubing connection / M6 / 66.5 cmWith light protection and protection against kinks.
6.01805.010
PTFE tubing connection / M8 / 66.5 cmWith light protection and protection against kinks.
6.01805.100
PTFE tubing with Luer 60 cmTubing for the connection between peristaltic pump 1 or 3 in the pump module with the distributor (rinsing) on the Pick&Place module.