Search
Market-leading solutions
Product families (69)Product configurations for any application
Product models (712)Tried-and-tested applications
Applications (2250)Electrodes
Electrodes (509)Columns
Columns (155)Accessories
Accessories (2246)Software
Software (266)Manuals & brochures
Documents (2601)News
News (54)Inspiring industry insights
Insights (177)Unmatched support & service
Support & service (79)Other content
Items (86)On-demand webinars
Webinars (72)Ti-Touch
Minimum bench space, maximum performance: A compact all-in-one potentiometric titrator for routine applications.
2060 The NIR Analyzer
A turnkey solution for Process Analytical Technology (PAT)
2060 XRF Process Analyzer
Reliable online x-ray fluorescence analysis for liquid process control
Modular Line
Build an instrument for electrochemical research that meets your exact requirements with only specifications and features you need.
780/781 pH/ion meters
The instruments of choice for pH, ORP, and ion concentration measurements.
Portable VA Analyzer
Portable voltammetric analyzers for the determination of trace levels of heavy metals in water in the field.
MISA
The premier portable trace detection system for rapid onsite detection of contaminants in food matrices: easy, fast, flexible, and sensitive.
Eco KF Titrator
High in quality, low in price: Swiss-made, affordable solution for routine volumetric Karl Fischer titration.
Hyphenated techniques
Extending the scope of ion chromatography: sophisticated sampling, sensitive detection, or multi-parameter analysis.
Eco Titrator
Swiss-made quality at an affordable price? This potentiometric titrator offers even more.
2.913.0210
913 pH Meter, laboratory versionPortable two-channel pH measuring instrument for measuring pH/mV and temperature. You will be optimally equipped for measurements in the field and in the laboratory with this battery-operated measuring instrument with a stand plate. Portable pH meter with built-in battery pack and two galvanically isolated pH measuring inputs.; Analog pH measuring input for Metrohm standard pH electrodes; Digital pH measuring input for the intelligent pH electrodes from Metrohm; Robust, water-tight, and dust-tight housing (IP67) for tough outdoor and laboratory use; LCD color display with background illumination making results easy to read; USB interface for simple data export to PC or printer; Large internal memory (10,000 data sets); Pin-protected User mode and Expert mode, prevents unwanted parameter changes; GLP-compliant printout and data export with User ID and timestamp;
2.913.0220
913 pH/DO Meter, laboratory versionPortable two-channel measuring instrument for measuring pH/mV and for measuring the amount of dissolved oxygen in water. You will be optimally equipped for measurements in the field and in the laboratory with this battery-operated measuring instrument with a stand plate.Measuring instrument with built-in battery pack and two galvanically isolated measuring inputs.; Analog pH measuring input for standard pH electrodes; Digital pH measuring input for the intelligent pH electrodes or O2 Lumitrode; Robust, water-tight, and dust-tight housing (IP67) for tough outdoor and laboratory use; LCD color display with background illumination making results easy to read; USB interface for simple data export to PC or printer; Large internal memory (10,000 data sets); Pin-protected User mode and Expert mode, prevents unwanted parameter changes; GLP-compliant printout and data export with User ID and timestamp; With stand plate and electrode holder;
2.914.0020
914 pH/ConductometerTwo-channel pH/conductivity measuring instrument for measuring pH/mV/conductivity/TDS/salinity and temperature. You will be optimally equipped for measurements in the field with this battery-operated measuring instrument. Portable pH/conductivity measuring instrument with built-in battery pack; Parallel measurement of pH value and conductivity; Analog pH measuring input for Metrohm standard pH electrodes; Analog conductivity measuring input for the 4-conductor conductivity measuring cells from Metrohm; Robust, water-tight, and dust-tight housing (IP67) for tough outdoor and laboratory use; LCD color display with background illumination making results easy to read; USB interface for simple data export to PC or printer; Large internal memory (10,000 data sets); Pin-protected User mode and Expert mode, prevents unwanted parameter changes; GLP-compliant printout and data export with User ID and timestamp;
2.914.0030
914 pH/DO/ConductometerPortable two-channel pH/DO/conductivity measuring instrument with intelligent measuring input for the parallel measurement of pH/mV and conductivity or dissolved oxygen and conductivity in water.Parallel measurement of pH value and conductivity or of dissolved oxygen and conductivity; Analog conductivity measuring input for the 4-conductor conductivity measuring cells; Digital measuring input for the intelligent pH electrodes or the intelligent O2 Lumitrode; Robust, water-tight, and dust-tight housing (IP67) for tough outdoor and laboratory use; LCD color display with background illumination for simple legibility of the results; USB interface for simple data export to the PC or the printer; Large internal memory (10,000 data sets); Pin-protected User mode and Expert mode, prevents unwanted parameter changes; GLP-compatible printout and data export with User ID and timestamp;
2.914.0120
914 pH/Conductometer with accessories casePortable two-channel pH/conductivity measuring instrument for parallel measurement of pH/mV/conductivity/TDS/salinity and temperature. You will be optimally equipped for measurements outdoors with this battery-operated measuring instrument. Parallel measurement of pH value and conductivity; Analog pH measuring input for Metrohm standard pH electrodes; Analog conductivity measuring input for the 4-conductor conductivity measuring cells from Metrohm; Robust, water-tight, and dust-tight housing (IP67) for tough outdoor and laboratory use; LCD color display with background illumination making results easy to read; USB interface for simple data export to PC or printer; Large internal memory (10,000 data sets); Pin-protected User mode and Expert mode, prevents unwanted parameter changes; GLP-compliant printout and data export with User ID and timestamp; Robust transport case for routine measurements in the field;
2.914.0130
914 pH/DO/Conductometer with accessories casePortable 2-channel pH/DO/conductivity measuring instrument with analog and digital measuring input for parallel measurements of pH/mV/conductivity or dissolved oxygen and conductivity. You will be optimally equipped for measurements outdoors with this battery-operated measuring instrument in a transport case.Parallel measurement of pH value and conductivity; Parallel measurement of dissolved oxygen and conductivity; Analog conductivity measuring input for the 4-conductor conductivity measuring cells from Metrohm; Digital measuring input for the intelligent pH electrodes and O2 Lumitrode; Robust, water-tight, and dust-tight housing (IP67) for hard outdoor and laboratory use; LCD color display with background illumination making results easy to read; USB interface for simple data export to PC or printer; Large internal memory (10,000 data sets); Pin-protected User mode and Expert mode, prevents unwanted parameter changes; GLP-compliant printout and data export with User ID and timestamp; Robust transport case for routine measurements in the field;
2.914.0220
914 pH/Conductometer, laboratory versionPortable two-channel pH/conductivity measuring instrument for measuring pH/mV/conductivity/TDS/salinity and temperature. You will be optimally equipped for measurements in the field and in the laboratory with this battery-operated measuring instrument with a stand plate. Analog pH measuring input for Metrohm standard pH electrodes; Analog conductivity measuring input for the 4-conductor conductivity measuring cells from Metrohm; Laboratory pH and conductivity measuring instrument with built-in battery pack; Parallel measurement of pH value and conductivity; Robust, water-tight, and dust-tight housing (IP67) for tough outdoor and laboratory use; LCD color display with background illumination making results easy to read; USB interface for simple data export to PC or printer; Large internal memory (10,000 data sets); Pin-protected User mode and Expert mode, prevents unwanted parameter changes; GLP-compliant printout and data export with User ID and timestamp;
2.914.0230
914 pH/DO/Conductometer, laboratory versionPortable two-channel pH/DO/conductivity measuring instrument with intelligent measuring input for measuring dissolved oxygen/pH/mV and analog measuring input for conductivity/TDS/salinity and temperature. You will be optimally equipped for measurements in the field and in the laboratory with this battery-operated measuring instrument with a stand plate.Digital measuring input for the O2 Lumitrode or the intelligent pH electrodes; Analog conductivity measuring input for the 4-conductor conductivity measuring cells; Laboratory pH/DO and conductivity measuring instrument with built-in battery pack; Parallel measurement of pH value and conductivity; Parallel measurement of oxygen and conductivity; Robust, water-tight, and dust-tight housing (IP67) for tough outdoor and laboratory use; LCD color display with background illumination making results easy to read; USB interface for simple data export to PC or printer; Large internal memory (10,000 data sets); Pin-protected User mode and Expert mode, prevents unwanted parameter changes; GLP-compliant printout and data export with User ID and timestamp;
2.919.0020
919 IC Autosampler plusThe 919 IC Autosampler plus fulfills the requirements of laboratories with medium sample numbers. It enables automation of the full range of Metrohm IC instruments.
2.922.0010
DS2500 Solid AnalyzerRobust near-infrared spectroscopy for quality control, not only in laboratories but also in production environments.The DS2500 Analyzer is the tried and tested, flexible solution for routine analysis of solids, creams, and optionally also liquids along the entire production chain. Its robust design makes the DS2500 Analyzer resistant to dust, moisture, vibrations, and temperature fluctuations, which means that it is eminently suited for use in harsh production environments.The DS2500 covers the full spectral range from 400 to 2500 nm and delivers accurate, reproducible results in less than one minute. The DS2500 Analyzer meets the demands of the pharmaceutical industry and supports users in their day-to-day routine tasks thanks to its simple operation.Thanks to accessories tailored perfectly to the instrument, optimum results are achieved with every sample type, no matter how challenging it is, e.g. coarse-grained solids such as granulates or semi-solid samples such as creams. The MultiSample Cup can help improve productivity when measuring solids, as it enables automated measurements of series containing up to 9 samples.
- 410000030-A410000030-APortable Transmission Raman Spectroscopy for At-Line Content Uniformity Testing of Pharmaceutical Tablets
Analytical methods to perform CU testing should ideally be fast, noninvasive and achieved with limited sample preparation. Recently, transmission near-infrared (NIR) spectroscopy and transmission Raman spectroscopy have both been explored as alternative methods for rapid and non-destructive on- and at-line CU testing with no sample preparation. Although quick and nondestructive, transmission NIR spectroscopy suffers from poor chemical selectivity and is sensitive to changes in the testing environment. Transmission Raman spectroscopy combined with chemometric modeling is quickly emerging as a valued technique for CU testing due to its high chemical specificity, which is particularly useful when dealing with complex pharmaceutical formulations that contain multiple components.
- 410000031-A410000031-ARapid Field Testing of Ecstasy Pills Using a 1064-nm Handheld Raman Device
B&W Tek’s TacticID®-1064 is a field-ready handheld Raman system utilizing 1064-nm wavelength laser excitation. Designed for forensic analysis by safety personnel, first responders, and law enforcement personnel, the TacticID-1064 significantly reduces fluorescence, allowing users to identify tough street samples such as ecstasy tablets in a variety of colors and mixture forms.
- 410000032-A410000032-APros and Cons of Using Correlation Versus Multivariate Algorithms for Material Identification via Handheld Spectroscopy
The two most common mathematical representations used with handheld Raman spectroscopy as decision-making tools for spectroscopic data: Hit Quality Index (HQI) and significance level (p-value) are presented.
- 410000033-A410000033-AMicro-Raman Spectroscopy in Thin Section Analysis of Rock Mineralogy
Correct identification of mineral phases in rock thin sections is essential to petrographic and petrologic analysis of rocks. Portable Raman coupled to an optical microscope gives chemical information along with the optical images to give a higher certainty of identification than traditionally used optical micropcopy alone.
- 410000034-A410000034-AThe Advantages of a Compact, Thermoelectrically-Cooled Fiber Optic Spectrometer for Raman and Fluorescence Spectroscopy
The benefits of a TE-cooled spectrometer in Raman systems are discussed to deliver lower system noise over longer integration times, resulting in lower limits of detection.
- 410000035-A410000035-AB&W Tek TacticID for Narcotics Identification
Forensics testing of samples encountered by law enforcement and customs agents is based on analytical techniques that are now being miniaturized and simplified and are making their way into field instrumentation. Field testing with Raman spectroscopy allows users to conduct reliable measurements at the point of arrest, reducing the burden on crime labs and accelerating the prosecution process.
- 410000036-A410000036-ACost & Benefits of Handheld Raman for Quality Control Testing of Incoming Raw Materials in the Pharmaceutical Supply Chain
Handheld Raman solutions have improved the ability to do complete incoming raw material testing quickly without the need for sample preparation. The NanoRam handheld Raman contributes to increased quality testing with a cost-effective technology used at point of receipt, thus minimizing steps to material acceptance, giving a high return on investment (ROI).
- 410000037-A410000037-AIn-situ Monitoring of a Moisture-Induced Polymorphic Transition using Raman Spectroscopy and Gravimetric Vapor Sorption
The combination of Raman spectroscopy and vapor sorption techniques provides a comprehensive understanding of vapor-solid interactions of pharmaceutical materials as it relates to the structural properties.This paper investigates the in-situ monitoring of a moisture-induced polymorphic transformation (D-mannitol from delta to beta form) using a combined Raman-vapor sorption technique.
- 410000038-A410000038-AMaterial ID through Dark Brown PVBag
This technical note is to demonstrate the NanoRam material identification through dark brown plastic bags. NanoRam is shown to work for material identification inside dark brown polyvinyl bag.
- 410000039-A410000039-AQuantitative Analysis of Solutions Using a High Resolution Portable Raman Spectrometer
Ternary mixtures of aqueous sugar solutions are measured and multivariate models of the concentration of analytes developed using BWIQ software.
Microbore ion chromatography
Microbore IC from Metrohm features 2-mm columns, microbore capillaries, and a new conductivity detector. This setup reduces eluent consumption and increases signal sensitivity, which leads to reduced costs, time savings, and better efficiency for your IC measurements.
Eluent generators
Automated production of hydroxide eluents and carbonate and nitric acid-based eluents for faster, safer, and more reliable measurements.
About Us
Based in Switzerland, Metrohm provides titration, ion chromatography, Raman and NIR spectroscopy, electrochemistry, and process analysis solutions to customers worldwide.
Automated analysis of water
The Laboratory of the Swiss Canton of Zurich uses OMNIS and TitrIC from Metrohm for fast, reliable, and reproducible drinking water analyses.
Polymer ID verification in under two minutes
Hauff-Technik relies on the handheld Raman spectrometer MIRA XTR from Metrohm for fast and reliable ID verification of incoming polymer pellets.
Quality control of beer
Feldschloesschen AG uses a combined system of titration and ion chromatography instruments from Metrohm to perform their quality control analyses of beers.
Underwater archaeology and metal detection
The Hublot team uses Metrohm voltammetry instruments for underwater metal detection.
Stool analysis in under one minute
A university laboratory in France uses the near-infrared spectrometer DS2500 Solid Analyzer for fast, easy, and hygienic stool analysis.
Quality control and RMID with a handheld device
Iris Biotech has consolidated their regular quality control testing on a single, handheld Raman spectrometer – MIRA P. This device allows the company to identify and verify the quality of materials in just a few seconds.
Flexible and reliable electrochemical recycling
ESy-Labs uses a Metrohm Autolab potentiostat to accurately compare potential electrode materials and gather more information about the reactions.
6.6068.113
StabNet 1.1 Multi CD: 3 licensesClient/server-compatible computer program for data handling and instrument control of stability measuring instruments. The software permits checks, data acquisition, evaluation and monitoring, as well as report generation of stability measurements.Graphical user interface for routine operations, extensive database programs, method development, system configuration, very flexible user administration, extensive data export functions, individually configurable report generator.StabNet Multi complies with the directives according to FDA 21 CFR Part 11.Dialog languages: German, English, Chinese, Polish.The following instruments are supported:892 Professional Rancimat; 893 Professional Biodiesel Rancimat; 895 Professional PVC Thermomat; Client/server version with 3 licenses for 3 computers with a max. of 4 stability measuring instruments per computer.
6.06000.000
OMNIS Software storage deviceLicense-based PC program for controlling complex OMNIS analysis systems. Sample-oriented operating procedures with numerous templates; Graphical method editor with numerous templates; Clearly organized and professional sample lists; Management of instruments, work systems, sensors, solutions; Dialog languages: German, English, Chinese;
6.06001.002
Function license MEAS U/T/pHFunction license for pH, potential and temperature measurement with one OMNIS Titrator
6.06001.085
Function license liquid handlingFor special liquid handling activities, e.g., pipetting with an OMNIS burette
6.06001.100
Function license DET"Dynamic equivalence point titration" function license for one OMNIS titration system.
6.06001.110
Function license MET"Monotonic equivalence point titration" function license for one OMNIS titration system.
6.06001.130
Function license TETFunction license TET for expanding an OMNIS titration system to include the TET titration mode for thermometric titration.
6.06001.150
Function license SET with conditioningFunction license "SET with conditioning" for expanding an OMNIS titration system to include the "SET with conditioning" titration mode
6.06001.160
Function license KFT with conditioningFunction license for volumetric Karl Fischer titration with conditioning for an OMNIS titration system.
6.06001.170
Function license KFCFunction license for coulometric Karl Fischer titration for one OMNIS Titrator
810
Screen-Printed Ruthenium Oxide ElectrodeScreen-Printed Ruthenium Oxide Electrode. Suitable for working with microvolumes, for decentralized assays or to develop specific sensors.
C013
Screen-Printed Silver Electrode (Aux.:C; Ref.:Ag)Screen-Printed Silver Electrode (Aux.:C; Ref.:Ag). Working Electrode of 1.6 mm diameter.
110AGNP
Silver Nanoparticles modified Screen-Printed Carbon ElectrodeSilver Nanoparticles modified Screen-Printed Carbon Electrode. Designed for the development of (bio) sensors with an enhanced electrochemical active area.
110BI
Bismuth Oxide modified Screen-Printed Carbon ElectrodeBismuth Oxide modified Screen-Printed Carbon Electrode. Ideal for the environmental friendly determination of heavy metals at ppb levels.
110CNF
Carbon Nanofibres modified Screen-Printed Carbon ElectrodeCarbon Nanofibres modified Screen-Printed Carbon Electrode designed for the development of (bio) sensors with an enhanced electrochemical active area.
110CNF-GNP
Carbon Nanofibres-Gold Nanoparticles modified Screen-Printed Carbon ElectrodeCarbon Nanofibres-Gold Nanoparticles modified Screen-Printed Carbon Electrode designed for the development of (bio) sensors with an enhanced electrochemical active area.
110CNT
Multi-Walled Carbon Nanotubes modified Screen-Printed Carbon ElectrodeMulti-Walled Carbon Nanotubes modified Screen-Printed Carbon Electrode designed for the development of (bio) sensors with an enhanced electrochemical active area.
110CNT-GNP
Multi-Walled Carbon Nanotubes-Gold Nanoparticles modified Screen-Printed Carbon ElectrodeMulti-Walled Carbon Nanotubes-Gold Nanoparticles modified Screen-Printed Carbon Electrode designed for the development of (bio) sensors with an enhanced electrochemical active area.
110CSQD
Core-shell Quantum Dots ZnS/CdSe modified Screen-Printed Carbon ElectrodeCore-shell Quantum Dots ZnS/CdSe modified Screen-Printed Carbon Electrode designed for the development of sensors with a different electrochemical active area. Also suitable to perform electrochemiluminescence experiments.
110GNP
Gold Nanoparticles modified Screen-Printed Carbon ElectrodeGold Nanoparticles modified Screen-Printed Carbon Electrode designed for the development of (bio) sensors with an enhanced electrochemical active area.
- Dec 13, 2019When do I have to exchange the filtration membrane with Inline Ultrafiltration?
Blog about Inline Ultrafiltration for your Metrohm ion chromatography system.
- Oct 18, 2021Best practice for separation columns in ion chromatography (IC) – Part 2
Blog on IC separation columns: chosing the right column length and diameter and optimizing the analyte separation.
- Nov 1, 2021The evolution of handheld 785 nm Raman spectroscopy: Raman extraction from fluorescence interference
Handheld 785 nm Raman spectroscopy offers excitation with shorter wavelengths, strong Raman scattering with short acquisition times, and high signal-to-noise ratio and with excellent spectral resolution.
- Nov 15, 2021NIR spectroscopy in the petrochemical and refinery industry: The ASTM compliant tool for QC and product screening – Part 3
Quality control of pyrolysis gasoline, pygas, and other petrochemical products according to ASTM standards using near-infrared spectroscopy.
- Jan 10, 2022USP <645> – simple automated analysis of ultrapure water
Blog post on automated analysis and quality control of ultrapure water used for injections and other medical and pharmaceutical applications.
- Feb 21, 2022Ion-selective electrodes: General tips - Part 1
Theory of ion measurement, types of ion-selective electrodes, why using TISAB or ISA solution for measuring ions, and more on our blog.
- May 2, 2022Ion-selective electrodes: Standard addition and direct measurement – Part 2
How to do standard addition and direct measurements with ion-selective electrodes.
- Jun 27, 2022NIR spectroscopy in the personal care and cosmetics industry: The ideal tool for QC and product screening – Part 1
Near-infrared spectroscopy in the personal care and cosmetic industry: basics, benefits, and applications.
- Nov 18, 2024Ion chromatography for the pharmaceutical industry
The principles of ion chromatography are introduced, then some applications and benefits of using IC for pharma analysis according to USP General Chapter <1065>.
- Mar 31, 2025How does X-ray fluorescence work?
X-ray fluorescence (XRF) is a nondestructive technique for identifying and quantifying elements in solids, liquids, and powders. Learn about XRF and how it works in this blog article.
6.1020.250
Metrosep A Supp 10 - 50/2.0The Metrosep A Supp 10 - 50/2.0 separation column is based on a high-capacity polystyrene-divinylbenzene copolymer with a particle size of only 4.6 µm. Temperature, flow and eluent composition can be used to modify the properties of the column to accommodate the current application directly. The 2 mm Metrosep A Supp 10 separation columns are packed with the same material as the corresponding 4 mm separation columns. The short length and associated relatively low overall capacity of this 50 mm column enable very rapid separations of standard anions.The Metrosep A Supp 10 - 50/2.0 is well-suited to simple separation problems and uncomplicated matrices. Thanks to its low flow, this microbore separation column is ideally suitable for IC-MS applications.
6.1020.270
Metrosep A Supp 10 - 75/2.0The Metrosep A Supp 10 - 75/2.0 separation column is based on a high-capacity polystyrene-divinylbenzene copolymer with a particle size of only 4.6 µm. This proven column concept optimized by Metrohm is characterized by its robust construction, great selectivity and outstanding separating efficiencies. The 2 mm Metrosep A Supp 10 separation columns are packed with the same material as the corresponding 4 mm separation columns. Temperature, flow and eluent composition can be used to modify the properties of the column to accommodate the current application directly.The capacity of the Metrosep A Supp 10 - 75/2.0 has been optimized with respect to two aspects: matrix and speed. A rapid baseline separation of the standard anions can also be achieved in samples of high ionic strength. Particularly suitable for IC-MS applications.
6.1020.210
Metrosep A Supp 10 - 100/2.0The Metrosep A Supp 10 - 100/2.0 separation column is based on a high-capacity polystyrene-divinylbenzene copolymer with a particle size of only 4.6 µm. The 2 mm Metrosep A Supp 10 separation columns are packed with the same material as the corresponding 4 mm separation columns. Temperature, flow and eluent composition can be used to modify the properties of the column to accommodate the current application directly.The A Supp 10 - 100/2.0 is the microbore column of choice for routine applications. Thanks to the high flow and pressure stability of this separation column, very rapid chromatograms with good separation of the ions can be achieved. The standard anions can thus be separated within less than three minutes. Particularly suitable for IC-MS applications.
6.1020.220
Metrosep A Supp 10 - 150/2.0The Metrosep A Supp 10 - 150/2.0 separation column is based on a high-capacity polystyrene-divinylbenzene copolymer with a particle size of only 4.6 µm. This proven column concept optimized by Metrohm is characterized by its robust construction, great selectivity and outstanding separating efficiencies. The 2 mm Metrosep A Supp 10 separation columns are packed with the same material as the corresponding 4 mm separation columns. Temperature, flow and eluent composition can be used to modify the properties of the column to accommodate the current application directly.The Metrosep A Supp 10 - 150/2.0 separation column is suitable for complex separation tasks with wide differences in concentrations. The Microbore version exhibits low eluent consumption and is therefore particularly suitable for IC-MS applications.
6.1020.230
Metrosep A Supp 10 - 250/2.0The Metrosep A Supp 10 - 250/2.0 separation column is based on a high-capacity polystyrene-divinylbenzene copolymer with a particle size of only 4.6 µm. This proven column concept optimized by Metrohm is characterized by its robust construction, great selectivity and outstanding separating efficiencies. The 2 mm Metrosep A Supp 10 separation columns are packed with the same material as the corresponding 4 mm separation columns. Temperature, flow and eluent composition can be used to modify the properties of the column to accommodate the current application directly.The Metrosep A Supp 10 - 250/2.0, as a microbore column, has a very high capacity. It is suitable for samples with high ionic strength, for complex separation tasks and for analyses in which great differences in concentration between the individual components are present. Thanks to its low flow, this microbore separation column is ideally suitable for IC-MS applications.
6.01032.410
Metrosep A Supp 17 - 100/4.0The Metrosep A Supp 17 columns are anion separation columns for use at room temperature with a very good price-performance ratio. The Metrosep A Supp 17 - 100/4.0 enables rapid separation of the standard anions. Thanks to its great flexibility with respect to flow rates (up to 1.8 mL/min), very short analysis times can be achieved, depending on the separation problem.
6.01032.420
Metrosep A Supp 17 - 150/4.0The Metrosep A Supp 17 - 150/4.0 separation column is the column of choice for anion determinations that require good separating efficiency and short separation times at room temperature. The maximum flow rate of 1.4 mL/min then also makes it possible to optimize the determination. The Metrosep A-Supp-17 columns convince with their good price-performance ratio.
6.01032.430
Metrosep A Supp 17 - 250/4.0The Metrosep A Supp 17 - 250/4.0 combines high separating efficiency with a good price-performance ratio without requiring the use of a column oven. The polystyrene-divinylbenzene basic material used guarantees a long service life for the column. Complex separation tasks can be solved on this column.
6.1031.410
Metrosep A Supp 16 - 100/4.0The Metrosep A Supp 16 is a high capacity separation column based on a surface-functionalized polystyrene-divinylbenzene copolymer. The functional groups are bonded covalently. The morphology of the anion exchanger results in unique selectivity. In addition, this column type is noteworthy for its high mechanical and chemical resilience.The column is well-suited to applications with a high ionic load but which require only relatively low resolution. Using the Metrosep A Supp 16 - 100/4.0 to determine bromate in water by means of the triiodide method (EPA 326, DIN EN ISO 11206) is another of its numerous applications.
6.1031.420
Metrosep A Supp 16 - 150/4.0The Metrosep A Supp 16 is ideal for high-capacity separation problems and distinguishes itself with its outstanding resolution. The Metrosep A Supp 16 - 150/4.0 is based on a surface-functionalized polystyrene-divinylbenzene copolymer. The functional groups are bonded covalently.The Metrosep A Supp 16 - 150/4.0 is characterized by outstanding resolution and solves the most difficult separation problems. The column is very well-suited to applications that have a high ionic load but that do not require the highest resolution. It is one of the standard columns in anion chromatography.
CAST1X8
μStat 8000(P) cable connector for individual Screen-Printed ElectrodesConnects μStat 8000(P) equipment with individual Screen-Printed Electrodes
EC.Raman.ECAT.Starter
Metrohm Hyphenated EC-Raman Starter Electrocatalysis SolutionIncludes a compact Autolab PGSTAT204 with an Electrochemical Impedance Spectroscopy (EIS) module installed, a B&W Tek i-Raman Plus 532 H System, a B&W Tek Raman Video Microsampling System (532 nm) and an Autolab Trigger cable.Discover simultaneous structural and functional information about your catalysts quickly without complicated setups or worries about synchronizing measurements. This is all possible with the EC-Raman Starter Solution.• An electrochemical workstation with high accuracy EIS.• Two editable hyphenated EC-Raman procedures for the NOVA software as well as the BWSpec software for extended data analysis.• Measurements are automatically synchronized.• 532 nm laser excitation for higher Raman signal.
FLWCL-SC
Flow Cell with screws for Screen-Printed ElectrodesMethacrylate (top part) wall-jet Flow-Cell for FIA. Suitable to be used with standard format Screen-Printed Electrodes with the electrochemical cell in the middle of the strip. Closing system with screws. Fittings included.
GPHOXSOL-AQU
Graphene Oxide Solution-AqueousAqueous Aqueous graphene Oxide Solution, based in the modification of the Hummer's Method specially designed for electrode modification providing an enhanced electrochemical active area and improved electronic transfer properties.- Available in 1.0 mL and 5.0 mL.
BWT-840000962
Raman Video Micro-Sampling System (532 nm)Video microscope sampling system for use with B&W Tek's lab and industrial Raman probes. Includes a 20x objective with a working distance of 16 mm. Offers manual rough and fine adjustment on the X, Y, and Z-axes, coaxial LED illuminator for target alignment, video camera for sample observation, and is compatible with standard microscope objectives. Probe not included, available separately. 532 nm configuration.BAC151C-532
CABSTATMULTI
μStat 8000(P)/4000(P) multichannel cable connector for conventional electrodesConnects the multichannel option of the μStat 8000(P)/4000(P) to up to 8/4 conventional WE sharing one conventional AUX and one conventional REF
CAC
Cable connector for Screen-Printed ElectrodesConnects DropSens Screen-Printed Electrodes to any kind of potentiostat. Recommended when working in batch or flow analysis.
FLWCL-IDE
Flow Cell for Interdigitated ElectrodesMethacrylate wall-jet Flow-Cell for FIA. Suitable to be used with IDE electrodes ref. G-IDEAU10, G-IDEAU5,G-IDEPT10, G-IDEPT5, G-IDECONAU10 and G-IDECONPT10. Closing system with powerful magnets. Fittings included.
MCSOL
Mesoporous Carbon SolutionMesoporous Carbon Solution is a homogeneous, black solution with a high purity of mesoporous carbon nanopowder.- Available in 1.0 mL and 5.0 mL
BICAC
Cable connector for Dual Screen-Printed ElectrodesConnects DropSens Dual Screen-Printed Electrodes to any kind of potentiostat. Recommended when working in batch or flow analysis.
- Voltammetry – Mercur...Voltammetry – Mercury handling
Rules on how to handle mercury to protect yourself and the environment.
- 884 Professional VA:...884 Professional VA: Stirrer maintenance
Video instructions on how to remove, clean, and install the stirrer of your 884 Professional VA.
- Voltammetry – FAQs...Voltammetry – FAQs
Find helpful FAQs regarding Multi-Mode Electrodes, Rotating Disk Electrodes, and reference electrodes.
- Maintenance of the B...Maintenance of the Bi drop electrode
Step-by-step video instructions on how to maintain your Bi drop electrode (cleaning of the electrode, regeneration of the electrode, and more).
- How to operate viva...How to operate viva
Video tutorials explain how to operate viva, the control and database software for voltammetry and cyclic voltammetric stripping instruments.
- How to operate the B...How to operate the Bi drop electrode
Step-by-step video instructions explain how to operate the Bi drop electrode (blank determination, sample preparation, long-term storage, and more).
- Preparation of the m...Preparation of the measuring vessel
Information on how to prepare the measuring vessel for your stability measurements. FAQs address further questions with regards to your conductivity measuring cell.
- Product Help: Stability measurement
Operation and maintenance information for your stability measurement instrument. More information can be found in the FAQ section.
- Cleaning after the d...Cleaning after the determination
Step-by-step instructions on how to clean the individual parts of your stability measurement instrument after a determination.
- Starting an oxidatio...Starting an oxidation stability measurement
Video tutorial on how to start an oxidation stability measurement using the Professional Rancimat.
- Mar 15, 2021Battery research and production
Metrohm has compiled an overview of analytical methods and dedicated applications used to analyze crucial parameters in battery research and production.
- Oct 17, 2022OMNIS 3.0 Software released
Metrohm is pleased to release OMNIS 3.0, the latest version of the company’s software for laboratory data management. Features such as compliance with 21 FDA CFR part 11 (compliance package), client/server installation, 3rd party data integration, and long-term support (LTS) versions meet the requirements especially, in the regulated environment.
- Jan 30, 2023Highly sensitive analysis of amines, organic acids, and other ionic substances
A series of free white papers investigates the unique benefits of hyphenating ion chromatography (IC) from Metrohm with sensitive mass spectrometers (MS) for the determination of carbohydrates, organic acids, as well as many other ionic substances.
- Jun 16, 2023Efficient sample preparation and high-capacity columns for successful food and beverage analysis
Ion chromatography (IC) is a versatile and indispensable tool for the analysis of various regulated components in food and beverage samples simultaneously in a single run. When analyzing such highly loaded matrices with IC, sample preparation and column capacity are two of the most essential factors for success.
- Aug 9, 2023Metrohm comprehensive USP Raman Library
Metrohm Spectro is delighted to announce the Comprehensive Metrohm USP Raman Library in support of our consolidated, compliant Raman product line. For MIRA P, NanoRam-1064, and i-Raman® systems with BWID software, it is the largest in-house USP library available.
- Jan 5, 2023Metrohm wins award from The National Institute on Drug Abuse (NIDA)
Metrohm’s SERS expert and inventor of P-SERS strips, Dr. Wei Yu, has been awarded a grant from the National Institute on Drug Abuse (NIDA) for a portable Raman-based postmortem toxicology screening method.
- May 1, 2023Semiconductor production
Metrohm is pleased to present a free overview of analytical methods that are used for monitoring critical QC parameters in semiconductor production.
- Jun 15, 2023Metrohm Spectro included in National Science Foundation Regional Innovation Engines Development Award
Metrohm Spectro is proud to announce it is one of eleven companies and twelve universities receiving a regional Innovation Engines Development Award from National Science Foundation (NSF) as a part of its involvement with the Advancing Photonics Technologies (APT) collaboration of NJ, PA, NY and DE
- Sep 6, 2023Jun Zhao wins 2024 Williams-Wright Award from the Coblentz Society
Dr. Jun Zhao from Metrohm Spectro has been named the 2024 Williams-Wright Award recipient from the Coblentz Society. The Society presents the Williams-Wright Award annually to a spectroscopist who has made significant contributions to vibrational spectroscopy while working in industry.
- Nov 28, 2022Chemical analyses for the production of lithium-ion batteries
Learn how to determine the water content, residual alkali content, ionic impurities, metal composition of cathode materials, and battery electrolyte composition.
- 8.000.51008.000.5100Brochure: Metrohm Software Care – Security and productivity through regular maintenance
The present brochure describes the advantages of Metrohm Software Care. Metrohm Software Care is the perfect supplement to your Metrohm Care Contract. The fact that the hardware of your Metrohm analysis system requires regular maintenance is obvious: Signs of wear appear in the mechanics following continuous operation for years at a time, an electronic contact may become corroded or a motor may age. With Metrohm Software Care, you are on the safe side from the start – and remain there. You profit from the maximum performance of your analysis system, minimum downtimes and are optimally secured against the risk of data loss.
English
Other languages
- 8.000.51018.000.5101Brochure: ADI 2045TI Ex proof process analyzer – Safe online process analysis in explosion hazard environments
In explosion-hazard environments in which concentrations of flammable gases, vapors or dusts occur, it is imperative that measuring instruments be safe to operate and that they trigger no explosions. Metrohm Applikon has developed the third generation of wet-chemistry process analyzers specially for these environments. This brochure introduces the ADI 2045TI Ex proof process analyzer.
English
Other languages
- 8.000.51078.000.5107Brochure: Environmental analysis – quality monitoring of water, soil and air
The effects of human activity on the environment are complex and require sensitive analysis procedures and powerful analytic instruments. As a leading manufacturer of instruments for chemical analysis, we are quite aware of these challenges. We offer you the most up-to-date of instruments and systems with which you can monitor the composition of your water, soil and air samples.
English
Other languages
- 8.000.51118.000.5111Brochure: Metrohm NIRSystems
Near-infrared spectroscopy is a versatile analysis procedure that has been applied successfully in the pharmaceutical and chemical industries for more than 25 years. This simple, rapid and non-destructive physical measurement method offers, for practically every sample matrix, an accurate and precise analysis of chemical and physical parameters comparable to reference methods.
English
Other languages
- 8.000.51148.000.5114Brochure: Dosing Package, pH Meter Package, Conductivity Package
The present brochure describes complete packages for professional Liquid Handling and pH and conductivity measurement for the pharmaceuticals industry.
English
Other languages
- 8.000.51198.000.5119Brochure: Metrohm Image Brochure
Metrohm AG is a worldwide leading manufacturer of precision instruments for chemical analysis. We have held the unchallenged Number 1 position for years in the area of electrochemical ion analysis, but we offer considerably more than just instruments. In our laboratories we develop tailored applications to help our customers ensure the quality of their products, comply with regulations and optimize processes.
English
Other languages
- 8.000.51228.000.5122Brochure: Metrohm Quality Service – Experts by your side
Under the name Metrohm Quality Service we provide you with services that make your everyday laboratory work simpler. Safer. And above all more predictable. Get in touch and let us know what we can do for you.
English
Other languages
- 8.000.51318.000.5131Brochure: Gradients in ion chromatography – Optimum separation with shorter duration of the analyses
The present brochure describes the advantages of gradients. The goal of ion chromatography reads: optimum separation of the analytes within an acceptable total duration of the analysis. It is not always possible to have both of these at once. Gradients provide an elegant solution to this problem: depending on the elution behavior of the individual ions, gradients alter the strength of the eluent, thus shortening retention times.
English
Other languages
- 8.000.51328.000.5132Brochure: Metrohm Portfolio
This brochure provides an overview of the Metrohm product portfolio.
English
Other languages
- 8.000.51348.000.5134Brochure: Suppression in anion chromatography – More sensitive analysis of anions and organic acids
Suppression plays a key role in the analysis of anions and organic acids using ion-exchange chromatography and conductivity detection. The patented Metrohm Suppressor Module (MSM) is a suppression solution that is just as reliable as it is sophisticated. Suppression with the MSM is optimized and simplified even further thanks to STREAM (Suppressor Treatment Reusing Eluent After Measurement).
English
Other languages