Search
Market-leading solutions
Product families (69)Product configurations for any application
Product models (712)Tried-and-tested applications
Applications (2250)Electrodes
Electrodes (509)Columns
Columns (155)Accessories
Accessories (2246)Software
Software (266)Manuals & brochures
Documents (2601)News
News (54)Inspiring industry insights
Insights (177)Unmatched support & service
Support & service (79)Other content
Items (86)On-demand webinars
Webinars (72)2.136.0400
PILS, Particle Into Liquid Sampler"Particle Into Liquid Sampler" for sampling aerosols. When coupled with ion chromatographs, the ionic composition of the aerosols can be determined automatically. No additional sample preparation is required to achieve this end.
2.136.0700
Combustion Module (Oven + ABD, AJ)The Combustion Module (Oven + ABD, AJ) enables sample digestion during pyrolysis and oxidation of all types of flammable samples. The Combustion Module consists of the combustion oven and the Auto Boat Driver (automatic sample introduction). Both are products made by Analytik Jena which have been optimized specially for coupling with ion chromatographs.
2.136.0710
Auto Boat Drive (AJ)The Auto Boat Drive (ABD) automatically guides the sample boats into the combustion oven. The sample can be put into the boat manually or using an appropriate sampler. This product made by Analytik Jena has been specially optimized for coupling with ion chromatographs.
2.136.0720
LPG/GSS Module (AJ)The LPG/GSS Module (AJ) is a sample injection system for either liquefied gases or gases under enhanced pressure. The module is controlled automatically and moves the respective amounts of gas to the combustion oven for combustion. The Analytik Jena product has been optimized specially for coupling with ion chromatographs.
2.136.0730
Combustion Module (Oven + LPG/GSS, AJ)The Combustion Module (Oven + LPG/GSS, AJ) enables sample digestion during the pyrolysis of liquefied gases and gases under pressure. The Combustion Module (Oven + LPG/GSS, AJ) is comprised of the combustion oven and the LPG/GSS module. Both are products of Analytik Jena which have been optimized specially for coupling with ion chromatographs.
2.136.0740
LPG Module (AJ)The LPG Module (AJ) is a sample injection system for liquefied gases. The module is controlled automatically and moves the respective quantities of gas to the combustion oven for combustion. This product from Analytik Jena has been specially optimized for coupling with ion chromatographs.
2.136.0750
Combustion Oven (AJ)The Combustion Oven (AJ) is part of the Metrohm Combustion IC system. It is part of the two Combustion Modules 2.136.0700 and 2.136.0730.
2.136.0800
MMS 5000 Autosampler (AJ)Autosampler MMS 5000 (AJ) made by Analytik Jena for use with the Metrohm Combustion IC for fully automatic analysis of liquid and solid samples. To adapt the modular Multi-Matrix sampler to the correct sample type, either the liquids kit (6.7303.000) of the solids kit (6.7302.000) must be used.
2.140.0200
Impact printer CUSTOM DP40-S4NNormal paper printer, paper width 58 mm (40 columns), serial interface RS 232C (DB9). U = 100...240 V, 50/60 Hz.
2.141.0100
USB thermal printer Neo'sCompact printer with USB interface for the Ti-Touch, the Titrino plus and Dosimat plus and the 91X Meter instruments.Paper width 60 mm (40 characters). Including 6.2151.120 USB cable.
- AB-085AB-085Analysis of jams, fruit and vegetable juices, and their concentrates
This Bulletin describes analysis methods for determining the following parameters: pH value, total titratable acid, ash alkalinity, formol number, total sulfurous acid, chloride, sulfate, calcium, and magnesium. These methods are suitable for the analysis of jams, fruit and vegetable juices, and their concentrates.
- AB-086AB-086Measuring the pH value of dairy products
This Bulletin describes methods for measuring the pH value of dairy products. Particular attention has been paid to the handling, maintenance, and storage of the pH electrodes.
- AB-087AB-087Analysis of dairy products
This Bulletin describes potentiometric titration methods for the determination of the acidity in milk and yoghurt according to DIN 10316, ISO/TS 11869, IDF/RM 150, ISO 6091 and IDF 86, the chloride content in milk, butter and cheese according to EN ISO 5943, IDF 88, ISO 15648, IDF 179, ISO 21422, and IDF 242. Additionally the determination of the sodium content in milk using the thermometric titration is described. The determination of the oxidation stability of butter in accordance to AOCS Cd 12b-92, ISO 6886 and GB/T 21121 as well as the determination of lactose in lactose free milk by ion chromatography is also described.For the determination of the pH value in dairy products see Application Bulletin AB-086 and for the determination of calcium and magnesium see Application Bulletin AB-235.
- AB-089AB-089Potentiometric analysis of anodizing baths
This Bulletin describes potentiometric titration methods for checking sulfuric acid and chromic acid anodizing baths. In addition to the main components aluminum, sulfuric acid, and chromic acid, chloride, oxalic acid, and sulfate are determined.
- AB-090AB-090Potentiometric analysis of tin plating baths
Potentiometric titration methods for the analysis of acid and alkaline tin plating baths are presented. The following methods are described: tin(II) / tin(IV) / total tin, free fluoroboric acid, or free sulfuric acid, chloride in acidic tin baths, free hydroxide, and carbonate in alkaline tin baths.
- AB-091AB-091Potentiometric analysis of brass and bronze plating baths
Methods are described for the potentiometric analysis of the following bath components:Brass plating bath: copper, zinc, free cyanide, ammonium, carbonate, and sulfite.Bronze plating bath: copper, tin, and free cyanide.
- AB-092AB-092Potentiometric analysis of lead plating baths
This Bulletin describes the potentiometric determination of lead, tin(II), and free fluoroboric acid.
- AB-093AB-093Potentiometric analysis of cadmium plating baths
This Bulletin describes titrimetric methods for the determination of cadmium, free sodium hydroxide, sodium carbonate, and total cyanide. The free cyanide can be calculated from the total cyanide and the Cd content.
- AB-096AB-096Determination of mercury at the rotating gold electrode by anodic stripping voltammetry
This Application Bulletin describes the determination of mercury by anodic stripping voltammetry (ASV) at the rotating gold electrode. With a deposition time of 90 s, the calibration curve is linear from 0.4 to 15 μg/L; the limit of quantification is 0.4 μg/L.The method has primarily been drawn up for investigating water samples. After appropriate digestion, the determination of mercury is possible even in samples with a high load of organic substances (wastewater, food and semi-luxuries, biological fluids, pharmaceuticals).
- AB-097AB-097Determination of tocopherols (vitamin E) in edible oils and fats by anodic stripping voltammetry at a glassy carbon RDE
Edible oils and fats contain natural tocopherols and, in some cases, also synthetic tocopherols added as antioxidants. The method described below allows the simple and rapid determination of the tocopherol content by voltammetry. The tocopherols are oxidized electrochemically at the glassy carbon electrode (GCE). The limit of quantitation is approximately 5 ppm (mg/kg) tocopherol.
6.6065.008
Additional licenses update viva 1.x/2.x–3.x/4.x: 10 licensesUpdate of 10 additional licenses for viva 1.x/2.x to viva 3.x or viva 4.x.
6.6065.031
viva 3.x/4.x Multi: 1 additional licenseOptional license for viva Multi 3.x/4.x. The serial number of viva Multi 3.x/4.x is required for ordering!
6.6065.032
viva 3.x/4.x Multi: 5 additional licensesOptional licenses for viva Multi 3.x/4.x. The serial number of viva Multi 3.x/4.x is required for ordering!
6.6065.033
viva 3.x/4.x Multi: 10 additional licensesOptional licenses for viva Multi 3.x/4.x. The serial number of viva Multi 3.x/4.x is required for ordering!
6.6065.108
viva 1.x/2.x Full upgrade Multi: 3 licensesExtends viva Full with the functions of viva Multi version.
6.6065.216
viva 1.x/2.x Update 3.x/4.x Full: 1 licenseUpdate of viva 1.x Full or viva 2.x Full to viva 3.x Full or viva 4.x Full. Contains USB flash drive and update documentation.
6.6065.219
viva 1.x/2.x Update 3.x/4.x Multi: 3 licenses.Update of viva 1.x Multi or viva 2.x Multi to viva 3.x Multi or viva 4.x Multi. Contains USB flash drive and update documentation.
6.6065.302
viva 3.0 Full: 1 licenseComputer program for control and data management of Professional VA/CVS instruments. The software permits checks, data acquisition, evaluation, and monitoring, as well as report generation.Graphic user interface for routine operations, extensive database programs with reevaluation, graphic method editor with numerous templates, system configuration, very flexible user administration, extensive data export functions, individually configurable report generator.Includes the measuring modes "Differential Pulse" (DP), "Square Wave" (SQW), "Linear Sweep Voltammetry" (LSV), "Cyclic Voltammetry" (CV), "Cyclic Voltametric Stripping" (CVS), "Cyclic Pulse Voltammetric Stripping" (CPVS), and Chronopotentiometry (CP). The following calibration techniques are supported: standard addition, external calibration, DT (Dilution Titration), LAT (Linear Approximation Technique), MLAT (Modified Linear Approximation Technique), RC (Response Curve).Dialog languages: German, English, Chinese, Japanese.The following instruments are supported: 884 Professional VA, 894 Professional CVS1 license for a maximum of 4 Professional VA/CVS instruments on a single computer. Contains USB flash drive and installation documentation.
6.6065.303
viva 3.0 Multi: 3 licensesClient/server-compatible computer program for control and data management of Professional VA/CVS instruments. The software permits checks, data acquisition, evaluation, and monitoring, as well as report generation.Graphic user interface for routine operations, extensive database programs with reevaluation, graphic method editor with numerous templates, system configuration, very flexible user administration, extensive data export functions, individually configurable report generator.Includes the measuring modes "Differential Pulse" (DP), "Square Wave" (SQW), "Linear Sweep Voltammetry" (LSV), "Cyclic Voltammetry" (CV), "Cyclic Voltametric Stripping" (CVS), "Cyclic Pulse Voltammetric Stripping" (CPVS), and Chronopotentiometry (CP). The following calibration techniques are supported: standard addition, external calibration, DT (Dilution Titration), LAT (Linear Approximation Technique), MLAT (Modified Linear Approximation Technique), RC (Response Curve).Dialog languages: German, English, Chinese, Japanese.The following instruments are supported: 884 Professional VA, 894 Professional CVSClient/server version with 3 licenses for 3 computers with a max. of 4 Professional VA/CVS instruments per computer. Contains USB flash drive and installation documentation.
6.6065.308
viva 3.x/4.x Full Upgrade Multi: 3 licensesExtends viva Full 3.x or viva Full 4.x with the functions of the viva Multi version. Includes 3 licenses for 3 computers with a max. of 4 Professional VA/CVS instruments per computer.
6.00221.600
Ecotrode Gel with Pt1000Maintenance-free pH electrode (gel electrolyte) with integrated temperature sensor (Pt1000) for routine pH measurements in identical samples. This electrode is stored in c(KCl) = sat. (6.2308.000) and is not suitable for ion-deficient solutions.Thanks to the lifetime indicator, you always know early on when the electrode needs to be replaced.
6.00226.600
Spearhead electrode with Pt1000Maintenance-free combined pH electrode (gel electrolyte) for piercing measurements of all types (e.g., with cheese, meat, dough) with integrated Pt1000 temperature sensor. The electrode is stored in saturated potassium chloride solution c(KCl) = sat. (6.2308.000) and is not suitable for low-ion solutions. The ageing indicator gives early indication of when the electrode needs to be replaced.
6.00235.600
Porotrode with Pt1000 (connector U)Combined pH electrode with integrated Pt1000 temperature sensor for pH measurements/titrations in:samples containing protein (food, biological samples)extremely contaminated samplesviscous samplesThe specially developed capillary diaphragm and the reference electrolyte porolyte (6.2318.010) enable an optimum performance in samples containing protein. Storage in storage solution.
6.00249.540
Syntrode with plug-in head S (length 58.0 cm)Combined pH electrode, installation length 50.0 cm with plug-in head S. This electrode is well suited: for use in synthesis and bioreactors, e.g. for STAT titrations; at elevated temperatures; for long-term measurements; Thanks to the fixed ground-joint diaphragm, the electrode is insensitive to contamination, and is equipped with a storage vessel for the reference electrolyte.Reference electrolyte: c(KCl) = 3 mol/L, storage in storage solution.Alternatively: reference electrolyte for measurements at T > 80 °C: Idrolyte, storage in Idrolyte.
6.00249.600
Syntrode with Pt1000 (length 51.8 cm)Combined pH electrode with integrated Pt1000 temperature sensor, installation length 43.8 cm.This electrode is well suited:for use in synthesis and bioreactors, e.g., STAT titrations; at elevated temperatures; for long-term measurements; Thanks to the fixed ground-joint diaphragm, the electrode is insensitive to contamination, and it is equipped a storage vessel for the reference electrolyte.Reference electrolyte: c(KCl) = 3 mol/L, storage in storage solution.Alternatively: reference electrolyte for measurements at T>80°C: Idrolyte, storage in Idrolyte.
6.00257.000
Aquatrode Plus with Pt1000 (fixed cable)Combined pH electrode with integrated Pt1000 temperature sensor and fixed cable (2.0 m, banana plug 2 mm) for pH measurement/titration in low-ion aqueous media (e.g., drinking water, process water), and also exhibits an exceptionally rapid response time in these samples. The fixed ground-joint diaphragm is insensitive to contamination. Storage in storage solution is recommended when c(KCl) = 3 mol/L is used as bridge electrolyte.The bridge electrolyte can be replaced with a chloride-free electrolyte (e.g., potassium nitrate c(KNO3) = 1 mol/L (6.2310.010)), storage in used electrolyte.
6.00346.100
Double Pt ring electrode for volumetryIndicator electrode for Karl Fischer titration which, thanks to its two fused platinum rings, is more robust and easier to clean than the conventional platinum pin electrode (6.0338.100).
6.00348.100
Generator electrode with diaphragmGenerator electrode with diaphragm for coulometric Karl Fischer titrations, SGJ 29/22. This electrode has a cable connection angled upwards, which simplifies cable guiding and operation when used with the OMNIS Sample Robot Oven. This generator electrode is well-suited for:Samples with very low absolute water content < 50 ppm; Coulometric water content determination in oil samples; Applications where ketone reagents are used; Applications where low-conducting reagents are used (addition of chloroform, xylene >10%);
6.00349.100
Generator electrode without diaphragmGenerator electrode without diaphragm for coulometric Karl Fischer titrations, SGJ 29/22. This generator electrode is well-suited for most applications where the sample is highly soluble in alcohol.This electrode has a cable connection angled upwards.
6.00350.100S
Separate Ag ring electrode with Ag2S coatingThis silver ring electrode must be used in combination with a reference electrode (c(KNO3) = 1 mol/L as reference electrolyte) and is suitable for precipitation titrations (titrant silver nitrate), e.g. of: chloride, bromide, iodide; sulfides; hydrogen sulfide; mercaptans; cyanides; The permanently fused-in silver ring is resistant to highly concentrated acids and saline solutions and is coated with sulfide (Ag2S) for increased sensitivity and a better limit of detection.
- Nov 22, 2021Green hydrogen generation: A cross-disciplinary challenge rooted in electrochemistry
Basics about green hydrogen technology: performance indicators, reference electrodes, reversible hydrogen electrodes, and more.
- Nov 29, 2021Ph. Eur. 2.2.48 Raman Spectroscopy: How Raman instruments from Metrohm comply with the 2022 update
Compliance of handheld and portable Raman spectrometers with Ph. Eur. 2.2.48 for pharmaceutical quality control.
- Dec 6, 2021Side reactions in Karl Fischer titration
How to recognize and avoid side reactions in Karl Fischer titration that falsify results.
- Dec 13, 2021NIR spectroscopy in the petrochemical and refinery industry: The ASTM compliant tool for QC and product screening – Part 4
Quality control of lubricants based on mineral oils and synthetic oils according to ASTM standards using near-infrared spectroscopy.
- Jan 24, 2022NIR spectroscopy in the petrochemical and refinery industry: The ASTM compliant tool for QC and product screening – Part 5
Near-infrared spectroscopy and ASTM. Learn more about method development, method validation, and results validation.
- Feb 7, 2022Five myths about online dispersive NIR spectroscopy, FT-NIR, and FT-IR – Part 1
Learn more about near-infrared and infrared spectroscopy and the differences.
- Mar 7, 2022NIR spectroscopy: a 21 CFR Part 11 compliant tool for QC and product screening
Learn more about near-infrared spectroscopy as a 21 CFR Part 11 compliant tool to assess the quality of pharmaceuticals.
- Apr 4, 2022Five myths about online dispersive NIR spectroscopy, FT-NIR, and FT-IR – Part 2
The benefits of near-infrared spectrometers over IR photometers in process analytical technology.
- May 23, 2022Providing the Next Level of Safety with Hydranal™ NEXTGEN Reagents and OMNIS
Safe and accurate Karl Fischer titration with Metrohm OMNIS KF titrator and Hydranal™ NEXTGEN reagents.
- May 16, 2022History of Metrohm IC – Part 6
Blog post on the history of combustion ion chromatography from Metrohm for sulfur and halogen determination.
3500002010
Analog Ground CableThe Analog ground cable (AGND), is a single cable, 0.5 m in length, with one 2 mm and one 4 mm banana connectors, one on each end of the cable.This cable must be used only for ZRA (or ECN) measurements with VIONIC when operating with Floating ON.The Analog Ground Cable is an optional accessory and can be purchased separately.
3500002470
Autolab Test CellThe Autolab Test Cell provides a range of electrical circuits which can simulate typical electrochemical interfaces. It is equipped with color coded, 4 mm banana sockets (female connectors) which assure a direct connection to the 4 mm Banana Adaptive cables.The Autolab Test Cell can be used for testing the performance of the VIONIC instrument, testing and trobleshooting measurement procedures.
3500002500
4mm Banana Adaptive Cable SetEach 4mm Banana Adaptive Cable Set comes with 5 cables (Working/WE, Reference/RE, Counter/CE, Sense/S and Second Sense/S2) of 0.5 m in length.Each 0.5 m cable ends with a 4 mm banana cell connector.The 4 mm Banana Adaptive Cable Set is delivered with VIONIC and is also available to purchase separately.
3500002510
2mm Banana Adaptive Cable Set: 5 cables of 0.5 m ending with 2 mm banana connectorsEach 2 mm Banana Adaptive Cable Set comes with 5 cables (Working/WE, Reference/RE, Counter/CE, Sense/S and Second Sense/S2) of 0.5 m in length. Each 0.5 m cable ends with a 2 mm banana cell connector. The 2 mm Banana Adaptive Cable Set is an optional accessory for VIONIC.
3500002530
Alligator clip Adaptive Cable Set: 5 cables of 0.5 m ending with Alligator Clip connectorsEach Isolated BNC Adaptive Cable Set comes with 5 cables (Working/WE, Reference/RE, Counter/ CE, Sense/S and Second Sense/S2) of 0.5 m in length. Each 0.5 m cable ends with an Isolated BNC connector. The Isolated BNC Adaptive Cable Set is an optional accessory for VIONIC. The Isolated BNC Adaptive Cable Set is an optional accessory and can be purchased separately.
3500002540
Isolated BNC Adaptive Cable Set: 5 cables of 0.5 m ending with Isolated BNC connectorsEach Isolated BNC Adaptive Cable Set comes with 5 cables (Working/WE, Reference/RE, Counter/ CE, Sense/S and Second Sense/S2) of 0.5 m in length.Each 0.5 m cable ends with an Isolated BNC connector.The Isolated BNC Adaptive Cable Set is an optional accessory and can be purchased separately.
3500002750
4mm Banana Adaptive Cable Set for High Frequency EISEach 4mm Banana Adaptive Cable Set for High Frequency EIS comes with 3 cables (Working/WE, Reference/RE, and a Ground bridge cable) each 0.25 m in length. Each 0.25 m cable ends with a 4 mm banana cell connector. The 4 mm Banana Adaptive Cable Set for High Frequency EIS is delivered with VIONIC and is also available to purchase separately. These cables must be used ONLY for EIS measurements at frequencies higher than 1 MHz.
3500002880
GSTAT Floating Stabilization boxThe GSTAT Floating Stabilization box is for measurements conducted with VIONIC operated simultaneously in Galvanostatic and FLOATING mode.The GSTAT Floating Stabilization box is an optional accessory and can be purchased separately.
3500003120
Trigger cable for PGSTAT302N Hyphenated EC-Raman SolutionsThis trigger cable connects the Autolab PGSTAT302N to the i-raman plus 532H and synchronizes and controls spectra acquistion through the NOVA software.
3500003130
Trigger cable for PGSTAT204 Hyphenated EC-Raman SolutionsThis trigger cable connects the Autolab PGSTAT204 to the i-raman plus 532H and synchronizes and controls spectra acquistion through the NOVA software.