Aplikace
Aplikace
- AN-H-068Determination of ferric ion by iodometric titration
Determination of Fe3+ by iodometric titration. Useful if Fe3+ is accompanied by Al3+, Mg2+, Ca2+ and Fe2+.
- AN-CIC-004Total and leachable concentration of halogens and sulfur in latex gloves using Combustion Ion Chromatography and a leaching test
Latex gloves are used in clean room environments in order to prevent contaminations. The use of gloves that release corrosive halogenides or sulfate is forbidden in nuclear power plants. The total content of halogen and sulfur is determined by means of Combustion Ion Chromatography. An eluate test is carried out to check the elutable percentage of halogens and sulfate from gloves. Sample preparation is comprised of preconcentration and matrix elimination (MiPCT-ME), as described in AN-S-304.Keyword: pyrohydrolysis
- AN-CIC-028Fluorine and chlorine in iron ore by Combustion Ion Chromatography
Iron ore is an important resource for steel production. Its natural content of halogens is a quality characteristic due to the corrosiveness of the respective halogenides. Combustion IC applying the sacrificial vial technology is used for the analysis of fluorine and chlorine in ore. WO3 usually is added to improve the release of SO2 and therefore sulfur recovery. In this application, it also significantly improves the recovery of fluoride.
- AN-CIC-003Chlorine, bromine and sulfur in low-density polyethylene (ERM®-EC680k) using Combustion IC
The determination of halogens and sulfur in waste products is important. The inline combination of the Mitsubishi Combustion Module with the Metrohm IC is a suitable method for this type of samples. The recovery rates are analyzed with a certified reference material, e.g., a low-density polyethylene (LDPE).Keyword: pyrohydrolysis
- AN-CIC-011Analysis of an ion exchanger using Metrohm Combustion IC
The manufacture of ultrapure water for the pharmaceuticals industry or the semiconductor industry requires high-quality ion exchangers. Metrohm Combustion Ion Chromatography is an indispensable tool in this connection for testing the purity of anion exchange material. The output sample was wet and had to be dried at 105 °C in a special oven with waste air evacuation.Keyword: pyrohydrolysis
- AN-CIC-021Halogen and sulfur in chlorinated and brominated halobutyl rubber applying Combustion IC
Halobutyl rubber is frequently used in the production of pharmaceutical stoppers. It is ideal for this application due to its low permeability to gases and its chemical resistance. Chlorinated and brominated butyl rubber stoppers are analyzed for their halogen and sulfur content. Halogen and sulfur compounds are released by pyrohydrolysis and analyzed by subsequent ion chromatography (IC).
- AN-CIC-002Halogens and sulfur in residual solvent using Combustion IC
Determination of fluoride, chloride, bromide and sulfate in residual solvent using combustion digestion as sample preparation and subsequent anion chromatography with conductivity detection following sequential suppression. The analysis is significant for use in dividing waste products into non-halogenated and halogenated solvents.Keyword: pyrohydrolysis
- AN-CIC-010Halogens in a polymer sample applying Metrohm Combustion IC according to IEC 60754
The Restriction of Hazardous Substances Directive (RoHS) requires to reduce the halogen content in several organic materials used in electrical and electronic equipment. In this context, there is a huge interest for using halogen-free polymers. To check for halogens in polymers according to standard IEC 60754, Metrohm Combustion IC applying flame sensor technology and Inline Matrix Elimination is an indispensable method. The examined polymeric material contains halogens at a level of up to 1%.
- AN-CIC-022Bromine content in polystyrene – optimization of the absorption solution for Combustion IC
Polystyrol is brominated to increase flame retardation. The brominated polystyrene finally consists of 25 to 35% of bromine. The determination of bromine by combustion ion chromatography (CIC) requires a specially optimized absorption solution to trap all bromide. This work shows the optimization of the absorption solution for high-bromine samples.
- AN-CIC-029Organic halides in crude oil
Crude oil typically contains no organic halides. These are introduced at production sites, in pipelines, or in storage tanks. These components produce HF, HCl, and other acids in reforming and hydro-treating processes, leading to corrosion and catalyst poisoning. Speciation of the halides is an important parameter to measure in order to trace the contamination source. The current specifications expect to find less than 2 mg/kg organic chlorine in crude oil. Sulfur in crude oil could be quantified on the fly. Due to the specific request in this application, only the halogens are determined.
- AN-CIC-035Halogens and sulfur in solid samples according to EN 17813
Organic halides must be monitored in the environment. Combustion ion chromatography (CIC) is used for accurate halogen analysis in solids following EN 17813:2023.
- AN-NIR-037Determination of polymorphous sulfathiazoles by near-infrared spectroscopy (NIRS)
Sulfathiazoles are sulfonamides with antibiotic effect that occur in various polymorphous forms and that are often used in veterinary medicine. This Application Note shows the differentiation between commercial and sulfathiazole form I using near-infrared spectroscopy (NIRS) with the help of the overtone frequencies of N-H stretching vibration. Form I is the least stable polymorphous form. Crystallization and polymorphism must be monitored as part of quality controls. In this, NIRS is considerably more rapid and more reliable than conventional laboratory methods.
- AN-NIR-005Determination of coatings on nylon fibers by near-infrared spectroscopy
This Application Note demonstrates how NIR spectroscopy can be used to determine the content of coatings on nylon fibers, quickly and without requiring either sample preparation or the use of reagents. In order to suppress the effects arising from scattering on the surface coatings, one forms the second derivative spectra; the linear least-squares regression method is used to calculate the calibration function.
- AN-NIR-030Determination of amine number and solid content of dipping paint
This Application Note shows how the amine number and the solids content in electrophoretic lacquer coatings can be determined quickly and simply with Vis-NIR spectroscopy. Additional parameters can be determined reliably and conveniently with a single measurement.
- AN-NIR-032Determination of the cotton linter and pulp content in cellulose
This Application Note shows the determination of the ratio of cotton linter to pulp in cellulose samples with Vis-NIR spectroscopy. This linter-pulp ratio is an important characteristic in the paper industry which, unlike with elaborate wet-chemistry methods, can be determined quickly and conveniently with Vis-NIR spectroscopy.
- AN-NIR-034Analysis of polymer granulate using near-infrared spectroscopy
This Application Note shows that near-infrared spectroscopy with its exceptionally short analysis times significantly accelerates quality monitoring of polymer granulates and raw materials. Polyethylene (PE) und polypropylene (PP) can be identified in parallel. PE density is also determined in the same measurement.
- AN-NIR-042Quantification of USP heparin units using near-infrared spectroscopy
Heparin acts as an efficient anticoagulant and, in addition to direct injection, is also used as a lock-flush solution for rinsing catheters. Vis-NIR spectroscopy can be used to determine the strength of contaminated and purified heparin. This Application Note demonstrates that heparin strength can be determined reliably with Vis-NIR spectroscopy.
- AN-NIR-053Moisture analysis of ethanol-hydrocarbon blends by Vis-NIR spectroscopy
This Application Note shows that visible near-infrared spectroscopy (Vis-NIRS) can determine water content in ethanol-hydrocarbon blends. Vis-NIRS is a fast alternative to conventional lab methods: it accelerates raw material inspection, process monitoring, and final product control.
- AN-NIR-072Rheological additive and wax in packaging paint by Vis-NIR spectroscopy – Multiple parameters with one measurement
Packaging has become an indispensable part in the food manufacturing process. To improve the appearance and properties of the packaging, a wide variety of coatings and inks are used. Different additives enhance rheological properties, control the wetting dispersion, or in the case of wax increase abrasion resistance. The regulations of these coatings in food packaging applications are very strict in some countries, creating the need for close monitoring of the production process.A fast, reliable, and simple to use solution for quantifying rheological additives and wax in such coatings is Visible-Near Infrared Spectroscopy (Vis-NIRS). Both parameters are determined simultaneously by Vis-NIRS in less than a minute.
- AN-NIR-010Process monitoring in a butyl acetate production stream using near-infrared spectroscopy
This Application Note describes an NIR method for monitoring the esterification process in butyl acetate production. The developed NIR method shows excellent analytical performance equivalent to that obtainable with more time-consuming GC methods.
- AN-NIR-031Purity, degree of substitution and water content of carboxymethyl celluloses
This Application Note shows how purity, degree of substitution and water content of carboxymethyl celluloses (CMC) can be determined conveniently and rapidly in a single measurement with Vis-NIR spectroscopy.
- AN-NIR-052Simultaneous determination of xanthan gum, optical density, and glucose in aqueous solutions by Vis-NIRS
Near-infrared spectroscopy (NIRS) was used as an analysis method for quality control of aqueous xanthan gum solutions. Quantitative models for the determination of optical density, glucose, and xanthan gum were developed, enabling fast and reliable quality control.
- AN-NIR-025Real-time inline predictions of jet fuel properties by NIRS
This Application Note describes the determination of various indices (mainly with ASTM and ISO conformance) for the characterization of kerosene as aviation turbine fuel using near-infrared spectroscopy. The following parameters were determined with the aid of an NIRS XDS Process Analyzer: degree of density in accordance with the American Petroleum Institute (API), aromatics content, Cetane Index, distillation characteristics pursuant to ASTM D86, flash point, freezing point, viscosity and hydrogen content. All of these parameters are determined quickly and easily with just a single measurement.
- AN-NIR-050Quantification of active ingredients in shampoo using near-infrared spectroscopy (NIR)
Near-infrared spectroscopy (NIRS) was used in a preliminary study as a fast and accurate method for the quantification of different preservatives and active ingredients in liquid shampoo. This Application Note shows how this analytical method allows the simultaneous determination of several constituents in shampoo in a single measurement.
- AN-NIR-067Simultaneous determination of multiple quality parameters in epoxy resins using Vis-NIR spectroscopy
This Application Note demonstrates the feasibility of Vis-NIRS for the simultaneous determination of multiple chemical and physical parameters in epoxy resins. Vis-NIRS is a fast alternative to conventional lab methods: it accelerates raw material inspection, process monitoring, and final product control.
- AN-NIR-024Quality control of pyrolysis gasoline
Pyrolysis gasoline (Pygas) is a by-product of ethylene production, which contains unwanted conjugated diolefins making it unsuitable as a motor fuel. To overcome this limitation, the olefin content needs to be reduced below 2 mg/g pygas in a selective hydrogenation unit (SHU). The diene value, or maleic anhydride value (MAV), is usually determined by the lengthy Diels-Alder wet chemical method (UOP326-17), requiring highly trained analysts. In contrast to the primary method, near-infrared spectroscopy (NIRS) is a cost-efficient and fast analytic solution for the determination of diene value in pyrolysis gasoline.
- AN-NIR-064Quality control of ammonium nitrate
Specialty chemicals have to fulfill multiple quality requirements. One of these quality parameters, which can be found in almost all certificates of analysis and specifications, is the moisture content. The standard method for the determination of moisture content is Karl Fischer titration.This method requires reproducible sample preparation, chemicals, and waste disposal. Alternatively, near-infrared spectroscopy (NIR) can be used for the determination of moisture content. With this technique, samples can be analyzed without any preparation and without using any chemicals.
- AN-NIR-044Multiparameter Quality Control of Palm Oil with NIR Spectroscopy
Determination of key quality parameters of palm oil, namely free fatty acids (FFA), iodine value (IV), moisture content, deterioration of bleachability index (DOBI), and carotene require the use of several different analytical methods, which are laborious and can lack in accuracy. This application note demonstrates that the XDS RapidLiquid Analyzer operating in the visible and near infrared spectral region (Vis-NIR) provides a cost-efficient and fast solution for the determination of these quality control parameters in palm oil. With no sample preparation or chemicals needed, Vis-NIR spectroscopy allows for the analysis of palm oil in less than a minute and can be used by anyone.
- AN-NIR-068Quality Control of Isocyanates
Determination of isocyanates (ASTM D7252) is a challenging procedure due to the reactivity of these organic species with atmospheric moisture, as well as their toxicity. Furthermore, HPLC analysis typically used for this kind of analysis involves sample preparation steps and chemicals, with each measurement taking up to 20 minutes to complete. This application note demonstrates that the XDS RapidLiquid Analyzer operating in the visible and near infrared spectral region (Vis-NIR) provides a chemical-free and fast solution (under one minute) for determination of isocyanate content.
- AN-NIR-078Automated moisture analysis in pharmaceutical peptides
The quantification of residual moisture in lyophilized pharmaceutical peptides is an important measure for quality control in the pharmaceutical industry. For development purposes, such measurements are necessary and routinely performed during stability studies and to optimize the freeze-drying process (lyophilization). Currently, Karl Fischer titration is widely used for moisture determination in routine analysis. However, this method is time consuming and destroys the sample during analysis. This Application Note shows that near-infrared spectroscopy (NIRS) is a fast, reagentless, non-destructive method to determine moisture content in lyophilized pharmaceutical products.
- AN-NIR-074Surfactant in laundry detergent by Vis-NIR spectroscopy
Liquid laundry detergents contain fabric softeners, bleachers, surfactants, as well as enzymes. Among these compounds, surfactant is the most important one for the cleaning effect, as it reduces the surface tension of the liquid.The quantification of surfactant is still often performed using primary methods such as two-phase potentiometric titration. However, prior to the analysis, time consuming sample preparation steps like dilution and pH adjustment are necessary. In contrast, Visible-Near Infrared Spectroscopy works without any sample preparation steps at all, saving time and costs, and avoiding chemical waste.
- AN-NIR-077Moisture analysis in caprolactam
Caprolactam is an important polymer used for the production of Nylon 6, which is the base material for industrial fibers. Due to its commercial significance, many different synthesis methods have been developed over the years. Caprolactam is hygroscopic and water soluble, therefore it is important to have a reliable analysis technique for water determination. Analyzing the water content by conventional methods requires each sample to be weighed, dissolved, heated, and titrated. Compared to the primary method, near-infrared spectroscopy (NIRS) offers unique advantages: it generates reliable results within seconds, but it does not need any sample preparation nor does it create chemical waste.
- AN-NIR-089Quality Control of Laminates
In the semiconductor industry, thermoset resins combined with fabric or paper are used as an intermediate layer between substrates of printed circuit boards (PCB). These polymer-based sheets (laminates) are chosen depending on thickness and their thermomechanical and electrical characteristics. Near infrared spectroscopy (NIRS) is a fast, non-destructive and easy-to-use analytical method which allows the measurement of multiple key quality parameters in less than a minute. The following Application Note describes the determination of the transition time of PCB laminates by NIRS, a parameter correlating with the thickness, glass transition temperature, and tensile strength of the material.
- AN-NIR-083Quality Control of HDPE, LDPE, and PP
Identification of individual polymers with FT-IR spectroscopy can be a challenge due to sample inhomogeneity especially when larger sample sizes need to be analyzed. This application note demonstrates that the DS2500 Solid Analyzer operating in the visible and near infrared spectral region (Vis-NIR) provides a reliable and fast solution for the identification of high-density polyethylene (HDPE), low-density polyethylene (LDPE), and polypropylene (PP). With no sample preparation or chemicals needed, Vis-NIR spectroscopy allows the identification of larger inhomogeneous sample amounts in less than a minute.
- AN-NIR-054Quality Control of Shampoo
Determination of sodium laureth sulfate (SLES), cocamidopropyl betaine (CABP), cocamidopropylamine oxide (CAW), cocamide diethanolamine (DEA), and carbopol in shampoo is a cost- and time-intensive process due to the use of large volumes of chemicals per analysis. This application note demonstrates that the DS2500 Solid Analyzer operating in the visible and near-infrared spectral region (Vis-NIR) provides a cost-efficient and fast solution for a simultaneous determination these parameters in shampoo. With no sample preparation or chemicals needed, Vis-NIR spectroscopy allows for the complete analysis in less than a minute.
- AN-NIR-094Bromine number in pyrolysis gasoline
This application note presents near-infrared spectroscopy (NIRS) as an alternative for bromine number determination in pyrolysis gasoline.
- AN-NIR-096Water in diesel with NIRS
This Application Note highlights near-infrared spectroscopy as a faster, cost-effective alternative to KF titration for predicting water content in diesel fuel.
- AN-NIR-092Quality Control of PVC foils
PVC (polyvinyl chloride) foils with a PVDC (polyvinylidene chloride) coating are often used for high performance packaging films like pharmaceutical blister packs or in food packaging. In multi-layer blister films, the PVC serves as the thermoformable backbone structure, whereas the PVDC coating acts as a barrier against moisture and oxygen. The Water Vapor Transmission Rate (WVTR) and Oxygen Transmission Rate (OTR) are influenced by the composition and the thickness of the coating. A fast way to monitor PVDC coating thickness is with near-infrared spectroscopy. Results are provided in a few seconds, indicating when adjustments in the polymer production process are necessary.
- AN-NIR-100Ash determination in polyethylene
The standard test method for ash content analysis is thermogravimetric analysis (TGA). Although TGA is easy to perform, it is time-intensive and requires the use of nitrogen gas. In contrast to the primary method, near-infrared spectroscopy (NIRS) is a fast analytical technique which can measure multiple parameters including ash content in polymers within one minute.
- AN-NIR-101Quality control of dried cannabis
Typically, cannabis potency testing is performed by HPLC, but the drawback is that it requires chemicals and it is time-consuming. Near-infrared spectroscopy (NIRS) is a preferred method for quantification of THC, CBD and CBG in dried cannabis because it provides results in less than a minute and does not require any chemicals.
- AN-NIR-115Multiparameter quality control of palm oil with NIR spectroscopy
Near-infrared spectroscopy (NIRS) quickly assesses key quality parameters in palm oil such as iodine value and fatty acid profile without sample preparation.
- AN-NIR-110Quality control of sugarcane juice
Brix, Pol, juice purity, reducing sugars, and total recoverable sugars are some of the many quality control (QC) parameters that must be analyzed in sugarcane juice. An alternative to other analytical methods is near-infrared spectroscopy (NIRS). NIRS allows the fast, simultaneous determination of several QC constituents without chemicals or sample preparation.
- AN-NIR-105Roasted coffee analysis by near-infrared spectroscopy
Near-infrared spectroscopy (NIRS) is a fast, chemical-free alternative analytical technology for caffeine and moisture analysis in roasted coffee beans and grounds.
- AN-NIR-111Iodine value, FFA, refractive index, and fatty acid composition in edible oils
Near-infrared spectroscopy can quickly determine multiple edible oil quality parameters simultaneously without sample preparation as shown in this Application Note.
- AN-NIR-112Intrinsic viscosity (IV) determination of recycled PET by NIR spectroscopy
Near-infrared (NIR) spectroscopy is able to determine the intrinsic viscosity of rPET in less than one minute without any sample preparation. This Application Note demonstrates that the Metrohm DS2500 Solid Analyzer operating in the visible and near-infrared spectral region (Vis-NIR) offers users an easier way to perform this analysis without the use of toxic chemicals.
- AN-NIR-121Water content in propylene glycol monomethyl ether (PGME)
Near-infrared spectroscopy (NIRS) can determine water content in PGME (propylene glycol monomethyl ether) within seconds as shown in this Application Note.
- AN-NIR-123Flour analysis by near-infrared spectroscopy (NIRS)
NIR spectroscopy offers fast, chemical-free analysis of ash, protein, moisture, and rheological properties in flour – ideal for routine lab or atline quality control.
- AN-NIR-131NIRS analysis of forages
NIR spectroscopy enables fast, reliable analysis of key quality parameters in alfalfa forage (e.g., protein, fiber, and moisture) without any sample preparation.
- AN-NIR-135Quality control of honey with NIR spectroscopy
NIR spectroscopy can measure several honey quality parameters simultaneously in just a few seconds without any sample preparation as shown in this Application Note.
- AN-NIR-134Paprika powder analysis with NIR spectroscopy
This study shows how NIR spectroscopy simultaneously measures capsaicin content, Scoville Heat Units, water activity, ASTA color, and ash content in paprika powder samples.