Filtro de Aplicações
- AB-042Determination of carbonyl compounds by potentiometric titration
Carbonyl compounds (CC) occur in many products, such as bio-oils and fuels, cyclic and acyclic solvents, flavors and mineral oils. Carbonyl compounds can be responsible for the instability of these products during storage or processing. Especially pyrolysis bio-oils are known to cause issues during storage, handling and upgrading. This bulletin describes an aqueous and a non-aqueous analytical titration method for the determination of carbonyl compounds by potentiometric titration.
- AN-NIR-098Quality Control of PVC granulate
To monitor the quality of PVC (polyvinyl chloride), it is important to measure the molecular weight during the production process, as this parameter has a significant influence on chemical and mechanical stability as well as fire retardant properties. The standard method to determine PVC molecular weight, defined here as the average weight of the molecules that make up the polymer, is by size exclusion chromatography (SEC). This analytical method is time-intensive and requires trained personnel to perform. Determining the molecular weight of PVC is easier with near-infrared spectroscopy (NIRS). NIRS provides results in just a few seconds and can quickly indicate when adjustments to the production process are necessary.are necessary.
- AN-NIR-100Ash determination in polyethylene
The standard test method for ash content analysis is thermogravimetric analysis (TGA). Although TGA is easy to perform, it is time-intensive and requires the use of nitrogen gas. In contrast to the primary method, near-infrared spectroscopy (NIRS) is a fast analytical technique which can measure multiple parameters including ash content in polymers within one minute.
- AN-V-114Cobalt in polyethylene terephthalate (PET)
Co is determined in polyethylene terephthalate (PET) after digestion in sulfuric acid and hydrogen peroxide. The application is carried out with adsorptive stripping voltammetry (AdSV) in ammonia buffer with dimethylglyoxime (DMG) as complexing agent.
- AN-V-113Titanium in polyethylene terephthalate (PET)
Ti is determined in polyethylene terephthalate (PET) after digestion in sulfuric acid and hydrogen peroxide. Adsorptive stripping voltammetry (AdSV) with mandelic acid as complexing agent is used for this application.
- AN-V-063Cyanide in gases resulting from the incineration of plastic insulating materials
Polarographic determination of cyanide in gases resulting from the incineration of plastic insulation materials after sample preparation.
- AN-CIC-022Bromine content in polystyrene – optimization of the absorption solution for Combustion IC
Polystyrol is brominated to increase flame retardation. The brominated polystyrene finally consists of 25 to 35% of bromine. The determination of bromine by combustion ion chromatography (CIC) requires a specially optimized absorption solution to trap all bromide. This work shows the optimization of the absorption solution for high-bromine samples.
- AN-NIR-068Quality Control of Isocyanates
Determination of isocyanates (ASTM D7252) is a challenging procedure due to the reactivity of these organic species with atmospheric moisture, as well as their toxicity. Furthermore, HPLC analysis typically used for this kind of analysis involves sample preparation steps and chemicals, with each measurement taking up to 20 minutes to complete. This application note demonstrates that the XDS RapidLiquid Analyzer operating in the visible and near infrared spectral region (Vis-NIR) provides a chemical-free and fast solution (under one minute) for determination of isocyanate content.
- AN-NIR-100Ash determination in polyethylene
The standard test method for ash content analysis is thermogravimetric analysis (TGA). Although TGA is easy to perform, it is time-intensive and requires the use of nitrogen gas. In contrast to the primary method, near-infrared spectroscopy (NIRS) is a fast analytical technique which can measure multiple parameters including ash content in polymers within one minute.
- AN-RS-007Identification of polymer masterbatches with Raman spectroscopy
Handheld Raman spectroscopy enables rapid polymer masterbatch analysis, while Metrohm’s XTR® algorithm mitigates fluorescence interference for accurate additive identification.