Application Finder
- WP-038FDA 21 CFR Part 11 Compliance by Metrohm Raman
Norms and Standards 21 CFR Part 11 is the FDA rule relating to the use of electronic records and electronic signatures.Recognizing the increasing impact of electronic media on critical data in regulated environments, the FDA met with members of the pharmaceutical industry in the early 1990s. The pharmaceutical industry and the FDA were interested in how they could accommodate paperless record systems and ensure the reliability, trustworthiness, and integrity of electronic records.
- WP-018FDA 21 CFR Part 11 Requirements for NIR Spectroscopy
This Metrohm White Paper shows the requirements demanded of the pharmaceutical industry by the FDA with respect to software products. Implementation examples of the regulations formulated by the FDA in 21 CFR Part 11 are presented using Vision Air Pharma Software.Key words: electronic signatures, audit trails, user management, documentation
- WP-031Lifecycle of multivariate methods according to United States Pharmacopeia Chapter <1039> Chemometrics
Chemometrics is a powerful tool widely used for method development in the pharmaceutical industry. This whitepaper describes the lifecycle of multivariate models and summarizes the workflow of the development of chemometrical models according to the new USP chapter <1039>.
- 8.000.6078Water determination in pharmaceuticals using an automated Karl Fischer Oven Technique
The poster describes the water determination in pharmaceuticals using the Karl Fischer oven technique.
- BWT-4916See-Through Science
Allowing non-destructive chemical identification through opaque materials, award-winning STRam represents an evolution in Raman technology.
- AB-140Titrimetric sulfate determination
This Bulletin describes three potentiometric, one photometric, one thermometric and one conductometric titration method for sulfate determination. The question of which indication method is the most suitable depends primarily on the sample matrix.Method 1: Precipitation as barium sulfate and back titration of the Ba2+ surplus with EGTA. Use of the ion-selective calcium electrode as indicator electrode.Method 2: As with Method 1, although with the electrode combination tungsten/platinum.Method 3: Precipitation titration in semi-aqueous solution with lead nitrate in accordance with the European Pharmacopoeia using the ion-selective lead electrode as indicator electrode.Method 4: Photometric titration with lead nitrate, dithizone indicator and the Optrode 610 nm, particularly suitable for low concentrations (up to 5 mg SO42- in the sample solution).Method 5: Thermometric precipitation titration with Ba2+ in aqueous solution, particularly suitable for fertilizers.Method 6: Conductometric titration with barium acetate in accordance with DIN 53127
- AB-410Pharmaceutical analysis using near-infrared spectroscopy
The present Application Bulletin contains NIR applications and feasibility studies using NIRSystems devices in the pharmaceutical industry. Qualitative and quantitative analyses of a wide variety of samples are part of this bulletin. Each application describes the instrument that was originally used for the analysis, as well as the system recommended for the analysis and the results that were achieved thereby.
- AN-NIR-027Identification of 46 medicinal and aromatic plants for the cosmetics and pharmaceuticals industry
This Application Note shows how, with the help of Vis-NIR spectroscopy and a special plant library, 46 different medicinal and aromatic plants, e.g., Organicum majoricum and Tilia cordata, can be conveniently identified on the basis of their spectrum. In comparison with alternative methods for the determination of plants, which are elaborate and require experienced scientists for their performance, the Vis-NIR method permits rapid and uncomplicated identification.
- AN-C-175Purity of 2-amino-N-(2,2,2-trifluoroethyl)-acetamide by ion chromatography
2-amino-N-(2,2,2-trifluoroethyl)-acetamide is a organic building block for synthesis of pharmaceutical products. Its purity is crucial for the success of the respective synthesis step. 2,2,2-trifluoroethylamine, glycine, and inorganic cations are of interest. Their total peak area is required to be < 2 % of the peak area of all peaks above the reporting level. Separation and quantification is achieved on a Metrosep C 4 - 250/4.0 cation column.
- AN-C-196Purity quantification of tris(hydroxymethyl)aminomethane (TRIS) with IC
Tris(hydroxymethyl)aminomethane (TRIS) is often used in life science applications and its purity must be monitored. This analysis is possible with ion chromatography.
- AN-S-370Chloride and sulfate impurities in potassium bicarbonate
Within the scope of the modernization of USP, chloride and sulfate are determined as impurities in potassium hydrogen carbonate (bicarbonate). USP41 monograph for potassium bicarbonate does not check for chloride and sulfate. Applying ion chromatography with conductivity detection after sequential suppression allows quantifying these impurities.
- AN-S-400Assay of nitrite in sodium nitrite
In severe cases of cyanide poisoning, sodium nitrite is used along with sodium thiosulfate for treatment. This Application Note describes the nitrite ion chromatography assay with the Metrosep A Supp 4 column and suppressed conductivity detection. This column equivalency study was in cooperation with the USP according to the USP General Chapter <621>.
- AN-T-109Iodine value in canola and olive oil
This Application Note presents a modified time-saving method to determine iodine value (IV) in edible oils based on several standards (EN ISO 3961, ASTM D5554, etc.).
- AN-T-137Determination of sulfate in sodium sulfate according to Ph. Eur.
In accordance with the European Pharmacopoeia, sodium sulfate is determined with the PB ISE.
- AN-T-090Determination of zinc sulfate
This Application Note describes the photometric determination of zinc sulfate using the Optrode at a wavelength of 610 nm. Complexometric titration of zinc requires EDTA as titrant and Eriochrome Black T as indicator. The method fully complies with Ph. Eur. and USP.
- AN-T-102Standardization of hydrochloric acid with TRIS
Titrants are normally bought ready to use. However, it is necessary to determine the accurate concentration of your titrant solution on a regular basis using a primary standard. To correct the mentioned variation, a so-called «titer factor» is applied. The titer can be easily and quickly assessed by using the Metrohm brand of autotitrators. Predefined calculation formulas implemented in Metrohm titrators or software, respectively, as well as the automatic storage of the titer factor, makes standardization a simple task.
- WP-097Why switch to OMNIS Client/Server (C/S)?
OMNIS Client/Server boosts business performance with scalable server management, cutting costs by reducing hardware, energy use, and maintenance across locations.
- AN-NIR-021Monitoring the purity of recovered solvents with NIRS
The purity of a recovered solvent (dichlormethane/methylene chloride) and two of its most important contaminants (methanol and water) are monitored with NIR spectroscopy.
- AN-T-113Hydroxyl number in castor oil and stearyl alcohol – Fast, pyridine-free method for pharmaceutical samples
The hydroxyl number (HN) is an important sum parameter for quantifying the presence of hydroxyl groups in chemicals. As a key quality parameter, it is determined in various substances. For pharmaceutical samples, USP chapter <401> and Ph. Eur. Chapter 2.5.3 describe the determination. However these methods either use toxic pyridine and require refluxing or have long reaction times.In this Application Note, an alternative method according to ASTM E1899 is presented. This method is pyridine-free and does not require refluxing or long reaction times. The determination is performed at room temperature with only a small sample size. The analysis including all preparation steps is performed with a fully automatic OMNIS system. This allows parallel analysis of multiple samples, increasing productivity in the laboratory by 50%.
- AN-T-112Acid value and free fatty acids in edible oils
This Application Note describes the titration of acid value and free fatty acids in different edible oils, based on the standards EN ISO 660, USP<401>, and Ph.Eur. 2.5.1.
- AN-T-231Determination of caffeine by direct titration
Direct titration is a simple and precise way to accurately measure the caffeine content in different nonaqueous products. The OMNIS Titrator equipped with a dSolvotrode reliably determines caffeine through flexible analyses combined with high-end software.
- 410000036-ACost & Benefits of Handheld Raman for Quality Control Testing of Incoming Raw Materials in the Pharmaceutical Supply Chain
Handheld Raman solutions have improved the ability to do complete incoming raw material testing quickly without the need for sample preparation. The NanoRam handheld Raman contributes to increased quality testing with a cost-effective technology used at point of receipt, thus minimizing steps to material acceptance, giving a high return on investment (ROI).
- 410000029See-through ID with Raman technology
Metrohm’s ST Raman technology enables fast, contactless identification of substances through opaque packaging, expanding safe, field-ready use of Raman spectroscopy.
- WP-017Near-infrared spectroscopy in pharmacopoeias
The pharmaceutical industry is very likely more comprehensively regulated that any other branch of industry. It therefore requires analytic methods that meet the requirements of regulations while at the same time being practical. This applies in particular for large sample quantities, such as are encountered with incoming goods inspections, for example. It is here that particularly rapid and simple analysis methods are called for which make routine analyses simpler and more efficient. This White Paper describes some of the most important regulations in the pharmaceutical analysis and shows how Vis-NIR spectroscopy can solve analytic problems in the pharmaceutical industry in accordance with regulations.
- WP-019Ion chromatography – a universal technique with many applications in the pharmaceutical industry
Ion chromatography is a flexible technique with a large selection of intended uses in the pharmaceutical industry. – A few development trends and the latest advances are displayed here.
- WP-063Recommendations for converting a manual titration procedure into an automated titration procedure
This white paper summarizes the steps involved in converting an existing manual titration procedure to semi-automated or automated titration procedures. It discusses topics such as selecting the right electrode and titration mode. For a better understanding, the discussion topics are illustrated with three examples.
- WP-068Recommendations for titration methods validation
The objective of validation of an analytical procedure is to demonstrate that it is suitable for its intended purpose. Recommendations for the validation of analytical methods can be found in ICH Guidance Q2(R1) Validation of Analytical Procedures: Text and Methodology and in USP General Chapter <1225> Validation of Compendial Procedures. The goal of this white paper is to provide some recommendations for the validation of titration methods.
- WP-092USP monograph modernization initiative leading to modern ion chromatography-based methods
The USP and FDA started to modernize several monographs and General Chapters. In many cases, IC-focused methods have replaced older, wet chemistry procedures. Learn more about the USP modernization initiative and the advantages of ion chromatography in this white paper.
- 8.000.6107USP Modernization Initiative: Ionic Impurities in Drug Substances by Ion Chromatography
This poster presented jointly with USP at AAPS meeting shows, that we successfully validated an IC method to determine chloride and sulfate in drug substances, potassium bicarbonate and potassium carbonate. The proposed IC method overcomes limitations of the turbidimetry/visual comparison methods.
- 8.000.6109USP Modernization Initiative: Iodide Assay by Ion Chromatography
Potassium iodide (KI) is used to treat overactive thyroid and to protect the thyroid gland from the effects of radiation from inhaled or swallowed radioactive iodine. Currently, in the USP Potassium Iodide Monograph, iodide identification is performed by wet chemistry and assay by manual titration, which has a history of reduced precision and accuracy. As part of USP’s global monograph modernization initiative, an alternative selective and sensitive method was developed and validated – ion chromatography (IC). The proposed IC method can also be used for the identification test as an alternative to wet chemistry.
- 8.000.6108Comparative Study of Moisture Analysis Techniques on Cannabis
Moisture in cannabis impacts potency and must be accurately determined. Loss on drying (LOD) is the most popular method for determining moisture in cannabis. Unfortunately, this technique is not specific to moisture and the loss of any volatile components, such as terpenes, will be incorrectly classified as moisture. Karl Fischer (KF) titration is the only chemically specific test for moisture. This poster describes the instrument used to determine moisture content by Karl Fischer titration and compares the results of this data to loss on drying.
- 410000026-AFast Ingredient Analysis of Edible Oils Using a Portable Raman Spectrometer
Edible oils are not only a major source of nutrition but also a key basic material in the food industry. Vegetable oils are increasingly important because of their high content in mono- and polyunsaturated fatty acids in comparison with animal fats. In this application note, the main ingredients of olive oil, camellia oil, arachis oil, sunflower seed oil, and colza oil are analyzed using a portable Raman spectrometer combined with chemometrics software.
- AB-077Volumetric water content determination according to Karl Fischer – Tips and tricks for volumetric Karl Fischer titration
This Application Bulletin gives an overview of the volumetric water content determination according to Karl Fischer. Amongst others, it describes the handling of electrodes, samples, and water standards. The described procedures and parameters comply with the ASTM E203.
- AB-137Coulometric water content determination according to Karl Fischer
This Application Bulletin gives an overview of the coulometric water content determination according to Karl Fischer.Amongst others, it describes the handling of electrodes, samples, and water standards. The described procedures and parameters comply with the ASTM E1064.
- AB-141Analysis of edible fats and oils – The seven most important parameters for quality control
As the determination of the exact content of individual glycerides in fats and oils is difficult and time-consuming, several fat sum parameters or fat indices are used for the characterization and quality control of fats and oils. Fats and oils are not only essential for cooking, they are also an important ingredient in pharmaceuticals and personal care products, such as ointments and creams. Consequently, several norms and standards describe the determination of the most important quality control parameters. This Application Bulletin describes eight important analytical methods for the following fat parameters in edible oils and fats:Determination of water content in accordance with the Karl Fischer method; Oxidation stability in accordance with the Rancimat method; Iodine value; Peroxide value; Saponification value; Acid value, free fatty acids (FFA); Hydroxyl number; Traces of nickel using polarography; Special care is taken to avoid chlorinated solvents in these methods. Also, as many of the mentioned methods as possible are automated.
- AB-428Automatic conductometry in water samples with low electrical conductivity in accordance with USP<645>
This Bulletin describes the automatic measurement of conductivity in water samples with low electrical conductivity in accordance with USP<645>. Conductivity measurement is demonstrated on the example of ultrapure water, which is used, among other things, to produce injection solutions in the pharmaceutical sector.
- AN-NIR-122Quantification of water in lactose with the OMNIS NIRS Analyzer
This Application Note shows how easy it is to determine water content in the pharmaceutical excipient lactose with reagent-free near-infrared spectroscopy.
- AN-C-188Ammonium impurities in potassium bitartrate
Potassium bitartrate for pharmaceutical use must comply with USP requirements. The actual monograph (USP 42) uses a colorimetric method for the determination of ammonium impurities. Ion chromatography allows the measurement in a single determination under the same conditions used for the potassium assay (see AN-C-181). In the course of the USP monograph modernization, this ion chromatographic approach makes this type of analysis even easier.
- AN-K-043Water in aniline
The water content of aniline is determined according to Karl Fischer in buffered solvent.
- AN-R-029Oxidation stability of cosmetic and pharmaceutical raw materials
Determining the oxidation stability of raw materials for the cosmetic and pharmaceutical industry.
- AN-S-375Fluoride in sodium fluoride for pharmaceutical use
Dental care products often contain sodium fluoride as an active ingredient. Manufacturers use the United States Pharmacopeia and National Formulary (USP-NF) Monograph «Sodium Fluoride» to quantify sodium fluoride and its anionic contaminants chloride and acetate in these products. The validated USP method proposes ion chromatography (IC) with suppressed conductivity detection to carry out the fluoride assay as well as the impurity determination in a single chromatogram.
- AN-S-380Monofluorophosphate and fluoride in sodium monofluorophosphate for pharmaceutical use
Ion chromatography (IC) with suppressed conductivity detection has been approved by the U.S. Pharmacopeia (USP) as a validated method to quantify the monofluorophosphate (MFP) content in sodium monofluorophosphate. This Application Note shows that all acceptance criteria for the USP Monograph «Sodium Monofluorophosphate» are fulfilled and the procedure was approved as a validated USP method.
- AN-V-061Iron speciation in water with the Multi-Mode Electrode pro
Accurate determination of Fe(II) and Fe(III) in water is crucial for many industries. Cathodic sweeping voltammetry (CSV) offers a robust, cost-effective solution.
- AN-T-088Photometric EDTA titration of bismuth nitrate according to Ph. Eur. and USP
This Application Note describes the photometric determination of bismuth nitrate using the Optrode (520 nm). The sample is titrated with EDTA solution past the endpoint; xylene-orange is used as the indicator. The method for bismuth nitrate fulfills the directives defined in the Ph. Eur. and the USP.
- AN-T-089Photometric EDTA titration of manganese sulfate according to Ph. Eur. and USP
This Application Note looks at the photometric determination of manganese sulfate using the Optrode (610 nm). Manganese is titrated with EDTA; Eriochrome Black T is used as indicator. The method complies with Ph. Eur. and the USP.
- AN-T-157Automatic potentiometric titration of sulfanilamide
The purity of sulfanilamide was determined by means of automatic potentiometric titration using sodium nitrite as the titrant. The solution was spiked with potassium bromide, because bromide ions catalyze diazotization titration.
- AN-T-227Determination of sodium lactate
Sodium lactate is a salt form of lactic acid used in many regulated industries—therefore an accurate determination of the lactate content is required and is already covered in several norms. One such monograph by the US Pharmacopoeia (USP) results in high accuracies and well-defined titration curves but uses titrants and solvents that are more costly than necessary. In comparison, the presented modified method from Metrohm requires a 1:1 mixture of water and acetone and uses aqueous hydrochloric acid as titrant, resulting in an estimated cost reduction of 40% per titration compared to the USP method (USP–NF 2021, Issue 2). Furthermore, the time needed for each analysis is reduced to just 12% of the USP method (excluding blank determination). This Application Note presents both methods to determine lactate content and shows the results obtained on an OMNIS system.
- AN-T-210Assay of potassium carbonate and potassium bicarbonate
This Application Note presents a potentiometric titration method for a potassium bicarbonate and potassium carbonate assay meeting all USP General Chapter <1225> requirements.
- AN-T-221SET titration of HPLC mobile phases
This Application Note shows the automatic pH adjustment of a mixture of acetonitrile, water and amine using a Metrohm titrator.
- AN-T-232Determination of caffeine by iodometric back titration
The iodometric back titration is a precise method used to accurately measure the caffeine content in various aqueous samples. Reliable determinations are made easy using the OMNIS Titrator equipped with a dPt Titrode.